Phase A meter error | 1002 | FC04 | uint16 | | R |
Phase B meter error | 1003 | FC04 | uint16 | | R |
Phase C meter error | 1004 | FC04 | uint16 | | R |
Neutral meter error | 1005 | FC04 | uint16 | | R |
Phase sequence error | 1006 | FC04 | uint16 | | R |
Neutral current | 1007 | FC04 | float32 | A | R |
Neutral current mismatch | 1009 | FC04 | uint16 | | R |
Neutral overcurrent error | 1010 | FC04 | uint16 | | R |
Total current | 1011 | FC04 | float32 | A | R |
Total active power | 1013 | FC04 | float32 | kW | R |
Total apparent power | 1015 | FC04 | float32 | VA | R |
Phase A voltage | 1020 | FC04 | float32 | V | R |
Phase A current | 1022 | FC04 | float32 | A | R |
Phase A active power | 1024 | FC04 | float32 | kW | R |
Phase A apparent power | 1026 | FC04 | float32 | VA | R |
Phase A power factor | 1028 | FC04 | float32 | | R |
Phase A overpower error | 1030 | FC04 | uint16 | | R |
Phase A overvoltage error | 1031 | FC04 | uint16 | | R |
Phase A overcurrent error | 1032 | FC04 | uint16 | | R |
Phase B voltage | 1040 | FC04 | float32 | V | R |
Phase B current | 1042 | FC04 | float32 | A | R |
Phase B active power | 1044 | FC04 | float32 | kW | R |
Phase B apparent power | 1046 | FC04 | float32 | VA | R |
Phase B power factor | 1048 | FC04 | float32 | | R |
Phase B overpower error | 1050 | FC04 | uint16 | | R |
Phase B overvoltage error | 1051 | FC04 | uint16 | | R |
Phase B overcurrent error | 1052 | FC04 | uint16 | | R |
Phase C voltage | 1060 | FC04 | float32 | V | R |
Phase C current | 1062 | FC04 | float32 | A | R |
Phase C active power | 1064 | FC04 | float32 | kW | R |
Phase C apparent power | 1066 | FC04 | float32 | VA | R |
Phase C power factor | 1068 | FC04 | float32 | | R |
Phase C overpower error | 1070 | FC04 | uint16 | | R |
Phase C overvoltage error | 1071 | FC04 | uint16 | | R |
Phase C overcurrent error | 1072 | FC04 | uint16 | | R |
Total active energy accumulated for all phases - perpetual count | 1162 | FC04 | float32 | kWh | R |
Total active returned energy accumulated for all phases - perpetual count | 1164 | FC04 | float32 | kWh | R |
Phase A total active energy | 1170 | FC04 | float32 | kWh | R |
Phase A fundamental active energy | 1172 | FC04 | float32 | kWh | R |
Phase A total active returned energy | 1174 | FC04 | float32 | kWh | R |
Phase A fundamental active returned energy | 1176 | FC04 | float32 | kWh | R |
Phase A lagging reactive energy | 1178 | FC04 | float32 | VARh | R |
Phase A leading reactive energy | 1180 | FC04 | float32 | VARh | R |
Phase A total active energy - perpetual count | 1182 | FC04 | float32 | kWh | R |
Phase A total active returned energy - perpetual count | 1184 | FC04 | float32 | kWh | R |
Phase B total active energy | 1190 | FC04 | float32 | kWh | R |
Phase B fundamental active energy | 1192 | FC04 | float32 | kWh | R |
Phase B total active returned energy | 1194 | FC04 | float32 | kWh | R |
Phase B fundamental active returned energy | 1196 | FC04 | float32 | kWh | R |
Phase B lagging reactive energy | 1198 | FC04 | float32 | VARh | R |
Phase B leading reactive energy | 1200 | FC04 | float32 | VARh | R |
Phase B total active energy - perpetual count | 1202 | FC04 | float32 | kWh | R |
Phase B total active returned energy - perpetual count | 1204 | FC04 | float32 | kWh | R |
Phase C total active energy | 1210 | FC04 | float32 | kWh | R |
Phase C fundamental active energy | 1212 | FC04 | float32 | kWh | R |
Phase C total active returned energy | 1214 | FC04 | float32 | kWh | R |
Phase C fundamental active returned energy | 1216 | FC04 | float32 | kWh | R |
Phase C lagging reactive energy | 1218 | FC04 | float32 | VARh | R |
Phase C leading reactive energy | 1220 | FC04 | float32 | VARh | R |
Phase C total active energy - perpetual count | 1222 | FC04 | float32 | kWh | R |
Phase C total active returned energy - perpetual count | 1224 | FC04 | float32 | kWh | R |