SOLARFOCUS therminator II touch
SOLARFOCUS
Monitors and controls a SOLARFOCUS pellet boiler via Modbus TCP.
Overzicht
Belangrijke uitlezingen
- Boiler temperature
- Boiler status
- Message number
- Door contact
- Boiler cleaning level
- Outside temperature

SOLARFOCUS
Monitors and controls a SOLARFOCUS pellet boiler via Modbus TCP.
9 lezen / 1 schrijven
| Naam | Adres | Functie | Type | Eenheid | Toegang |
|---|---|---|---|---|---|
2400 - Actual Boiler temperature Actual Boiler temperature | 2400 | FC04 | int16 | °C | R |
2401 - State Boiler status line State Boiler status line | 2401 | FC04 | uint16 | R | |
2404 - State Message number State Message number | 2404 | FC04 | int16 | R | |
2405 - State Door contact State Door contact | 2405 | FC04 | uint16 | R | |
2406 - State boiler cleaning level State boiler cleaning level | 2406 | FC04 | int16 | % | R |
2408 - Actual Outside temperature Actual Outside temperature | 2408 | FC04 | int16 | °C | R |
2409 - State Boiler Type of wood State Boiler Type of wood | 2409 | FC04 | uint16 | R | |
2412 - State Boiler filling State Boiler filling | 2412 | FC04 | uint16 | R | |
2307 - State Hot Water Operation mode State Hot Water Operation mode | 2307 | FC04 | uint16 | R | |
33406 - External outside temperature External outside temperature | 33406 | FC16 | int16 | °C | W |
ModbusCloud is het hardware- en softwareplatform waarmee installateurs Modbus-apparaten monitoren, visualiseren en aansturen vanuit één portaal. Dit sjabloon is één van honderden die je direct kunt gebruiken.

SOLARFOCUS
Controls and monitors Solarfocus heating and cooling systems via Modbus TCP.

SOLARFOCUS
Monitors and controls SOLARFOCUS biomass pellet boilers via Modbus TCP.

SOLARFOCUS
Controls SOLARFOCUS heat distribution units via Modbus TCP

SOLARFOCUS
Reads SOLARFOCUS solar collector and tank values via Modbus TCP.

Komfovent
Controls Komfovent Domekt recuperator ventilation via Modbus TCP

Fronius
Monitors Fronius Symo and Primo inverters via Modbus TCP

NIBE

SunSpec

Victron

FoxESS