SOLARFOCUS therminator II touch
Monitors and controls a SOLARFOCUS pellet boiler via Modbus TCP.
This template connects to a SOLARFOCUS therminator II touch pellet boiler via Modbus TCP. It reads boiler temperature, status, cleaning level, door contact, outside temperature, and hot water operation mode. It also allows writing an external outside temperature value.
- Protocol
- Modbus TCP
- Connection
- Ethernet, Modbus TCP
- Registers
- 10, read and write
- Brand
- SOLARFOCUS
- Key readings
- Boiler temperature · Boiler status · Message number · Door contact · Boiler cleaning level · Outside temperature
- Available commands
- External outside temperature
- Compatible models
- therminator II touch
- Last updated
Registers (10)
9 read, 1 write
| Name | Unit | Access | Address (Hidden until you enter your email) | Function (hidden) | Type (hidden) |
|---|---|---|---|---|---|
| 2400 - Actual Boiler temperature | °C | Read | |||
| 2401 - State Boiler status line | Read | ||||
| 2404 - State Message number | Read | ||||
| 2405 - State Door contact | Read | ||||
| 2406 - State boiler cleaning level | % | Read | |||
| 2408 - Actual Outside temperature | °C | Read | |||
| 2409 - State Boiler Type of wood | Read | ||||
| 2412 - State Boiler filling | Read | ||||
| 2307 - State Hot Water Operation mode | Read | ||||
| 33406 - External outside temperature | °C | Write |
Loading registers…
Send your device list
If a device is not in the library yet, we build the template for free as soon as we have the register data.
Use cases
- Monitor boiler temperature and status remotely on a live dashboard to reduce on-site service visits.
- Create an alert when the boiler cleaning level drops below a threshold to schedule preventive maintenance.
- Track door contact events to detect unauthorized access or incomplete service procedures.
- Send an external outside temperature value from a weather station to optimize the boiler heating curve.
- Log boiler status and message numbers over time to diagnose recurring faults for commercial heating installations.
- Combine boiler monitoring with PV and energy meter data for a complete hybrid energy overview.
Installation
Connect the ModbusCloud Gateway to the same network as the SOLARFOCUS ecoManager-touch controller via Ethernet.
Ensure Modbus TCP is enabled on the ecoManager-touch controller and note the IP address assigned to it.
Configure the gateway with the correct IP address and Modbus TCP port (typically 502) of the ecoManager-touch.
Import the SOLARFOCUS therminator II touch template from the ModbusCloud template library into your gateway configuration.
Verify that read registers starting at 2300 and the write register at 33406 return valid data by checking the live values in the ModbusCloud dashboard.
If external outside temperature writing is needed, confirm that the ecoManager-touch is configured to accept external temperature input.
Things to watch for
Where can I find the Modbus register documentation for the SOLARFOCUS therminator II touch?
SOLARFOCUS Modbus documentation is only available to registered SOLARFOCUS partners. The ModbusCloud template includes preconfigured register addresses. Refer to the template download area for the latest mapping instructions.
What data format do the temperature registers use?
All temperature registers are int16 values expressed in degrees Celsius. No additional scaling factor is required.
The gateway connects but all register values show zero or errors. What should I check?
Verify that Modbus TCP is enabled on the ecoManager-touch controller. Confirm the correct IP address and that port 502 is not blocked by a firewall. Also check that the register addresses in the template match your firmware version.
Can I write values other than external outside temperature to the boiler?
This template only supports writing the external outside temperature at register 33406. Additional write capabilities depend on what the ecoManager-touch firmware exposes over Modbus TCP.