Get your greenhouse data out of the climate computer
For climate computers, sensors and meters with a Modbus interface. See climate and energy per section in one portal.

From Modbus into your own dashboard
If the climate computer has a Modbus interface, the gateway reads the registers you choose.
See greenhouse temperature, RH, CO2, pipe temperature and screen position live, with 365 days of history. A dashboard puts them next to gas and power use per section.

- E+E EE872RS485, address 1RH82 %
CO2640 ppm - Eastron SDM630RS485, address 2P36.2 kW
What you can do with your greenhouse data
Your own dashboards per section
Put climate and energy next to the values of separate sensors. Export readings as CSV, or pull them into your own reporting via the REST API.
Early warning
Set an alert on RH above 90 percent or a pipe temperature below 40 °C. The email comes at night too.
Energy per section at a glance
Put the climate data next to gas and power use per section, and see which section uses more at the same greenhouse temperature.
Share with your crop advisor
Share a dashboard with your crop advisor via a link. The weekly summary arrives by email.
Your data is stuck in the climate computer's system
NightRH 94 %
The humid night
In section 3 the RH rises to 94 percent overnight. You only see it the next morning, in the climate computer's graph.
Annual overviewCopying figures
The energy report
The energy advisor asks for gas use per section over the past year. You look up the figures in three systems and type them into a spreadsheet.
Extra sensorNot connected
The separate CO2 sensor
You put up an extra CO2 sensor in the greenhouse. It is not connected to the climate computer, so its values end up nowhere.
Templates for sensors, valves and meters
These sensors, valves, humidifiers and meters have a template ready, so the scan recognises them.
For a climate computer with Modbus, we build the template for free as soon as we have the register data. You can also set up the registers yourself.
Browse the library| Manufacturer | Template | Modbus | Status |
|---|---|---|---|
| E+E Elektronik | E+E Elektronik EE872 - Modular 4 in 1 probe for CO2, humidity, temperature and pressure | RTU (RS485) | Template ready |
| Regmet | Regmet PALNM - Light intensity sensor | RTU (RS485) | Template ready |
| Ecowitt | Ecowitt WN90LP Modbus | TCP (network) | Template ready |
| Belimo | Belimo Energy Valve V3 Modbus TCP | TCP (network) | Template ready |
| Carel | Carel humiSonic Compact | RTU (RS485) | Template ready |
| Wilo | Wilo Stratos GIGA2.0 | RTU (RS485) | Template ready |
| Grundfos | Grundfos CIM 200 | RTU (RS485) | Template ready |
| Kamstrup | KAMSTRUP MULTICAL 403-603 | RTU (RS485) | Template ready |
| Eastron | Eastron SDM630 Series | RTU (RS485) | Template ready |
| Janitza | Janitza UMG96RME | RTU (RS485) | Template ready |
How your greenhouse data gets into the portal
Connect
Connect the climate computer and the sensors over the network or over RS485 with two wires, A and B.
Scan
Enter the serial number in the portal and start a scan. The gateway recognises the sensors and meters from the library.
Monitor
See temperature, RH and CO2 per section. Set up alerts, for example on RH above 90 percent.
Price per gateway, annual or lifetime
Gateway
€295 one-off
€275 from 10 units, €249 from 25, quote from 50
Portal
€149 per year
Including 4G data up to 30 MB per month
€495 one-off
4G data with a lifetime licence
Only when 4G is used
€1 per month
€95 for ten years
All prices excl. VAT. White label customer portal included. All prices
100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.
Want to see how it works?