Belimo Modbus templates
All 17 available Belimo templates for ModbusCloud.
Monitor Belimo HVAC valves, actuators and room sensors, flow, position, temperature, humidity, via Modbus RTU.
- Templates
- 17
- Connection
- Modbus RTU and TCP
- Registers
- 15 to 139 per template
- Compatible models
- ..M(C)24A-MOD · ..R24A-MOD · ..V(K)24A-MOD · ..F24A-MOD · ..RF24A-MOD · EV..R+(K)BAC(1) · EV..R3+BAC · EV..F+(K)BAC(1) · EV..R2+(K)BAC · EV..R2+MID · 22DTH-..5.. · 22UTH-..50X · MV-D3-MOD · V..M24A-LP1 · V..R24A-LP1 · CQ24A-BAC · EP...R2+BAC · PR..-BAC-.. · EP..R-R6+BAC · 22PF-1U · Belimo JR · UK24MOD · P-22RT..-1U00A-2 · P-22RT..-1U00D-2 · EP..R+MOD · P6..W..E-MOD · EP..R6+BAC · EP..R6+BAC-HH1 · EP..R6+BAC-HH2 · EP..R6+BAC-HHM
- Last updated
Belimo templates
14 via Modbus RTU, 3 via Modbus TCP
Belimo Air-Water Actuator Modbus RTUControls communicative damper and valve actuators via Modbus RTU.Modbus RTU10 read, 10 write
Belimo Energy Valve V3 Modbus TCPMonitors and controls hydronic energy flow with pressure-independent valve positioning.Modbus TCP40 read, 16 write
Belimo Energy Valve V4 Modbus TCPMonitors and controls energy valves with integrated flow, power, and temperature measurementModbus TCP62 read, 36 write
Belimo Temperature and Humidity Sensor Modbus RTUMeasures temperature, humidity, enthalpy, and dew point for duct or outside air applications.Modbus RTU12 read, 16 write
Belimo VAV-Compact Modbus RTUProvides integrated VAV/CAV pressure sensing, airflow control, and damper actuation via Modbus RTU.Modbus RTU16 read, 11 write
Belimo IoT Actuator Modbus TCPControls cloud-capable Belimo IoT actuators via Modbus TCP.Modbus TCP11 read, 5 write
Belimo CQ24A-BAC Modbus RTUControls communicative rotary actuators for zone valves via Modbus RTU.Modbus RTU8 read, 7 write
Belimo Temperature Humidity CO2 Sensor Modbus RTUMeasures CO2, humidity, and temperature for duct applications via Modbus RTU.Modbus RTU14 read, 25 write
Belimo 2-way EPIV V4 Modbus RTUCombines measuring, controlling, balancing, and shutting flow in one valve unit.Modbus RTU29 read, 18 write
Belimo PM-PR Actuator Modbus RTUControls rotary actuators for butterfly valves and dampers via Modbus RTU.Modbus RTU11 read, 9 write
Belimo 6-way EPIV V1 Modbus RTUControls a 6-way pressure-independent characterised control valve with real-time flow measurement.Modbus RTU19 read, 6 write
Belimo Flow Sensor Modbus RTUMeasures ultrasonic flow, temperature, and glycol concentration in HVAC water systems.Modbus RTU22 read, 3 write
Belimo JR Actuator Modbus RTUControls rotary actuators for butterfly valves via Modbus RTU.Modbus RTU18 read, 11 write
Belimo UK24MOD Modbus RTUBridges MP-Bus actuators to Modbus RTU for digital control and status monitoring.Modbus RTU90 read, 49 write
Belimo Room Operating Unit Modbus RTUMeasures room CO2, humidity, and temperature with adjustable setpoints via Modbus RTU.Modbus RTU13 read, 38 write
Belimo 2-way EPIV Modbus RTUControls pressure-independent characterised valves for HVAC water-side modulating controlModbus RTU16 read, 10 write
Belimo 6-way EPIV V4 Modbus RTUControls 6-way pressure-independent valves with ultrasonic flow measurement and condensation monitoring.Modbus RTU32 read, 26 write
The scan recognises these devices
Connect them to RS485 or the network and start a scan in the portal.
Gateway
Portal
Incl. 4G data up to 30 MB per month
Excl. VAT. White label customer portal included. All prices
Order your first gateway100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

Belimo is a Swiss manufacturer of HVAC field devices: electronic pressure-independent valves (EPIV 2-way and 6-way), rotary and linear actuators, ultrasonic flow sensors, and room operating units that measure temperature, humidity and CO2. The 17 Belimo Modbus RTU templates in our library cover the full EPIV range (V3 and V4), the Energy Valve, the VAV-Compact airflow controller, and the room and duct sensor families.
With ModbusCloud and Belimo Modbus RTU templates you get live valve position feedback, volumetric flow, temperature and delta-T, fault status, and setpoint or override control for heating and cooling circuits. Room sensors expose CO2 concentration, relative humidity, dew point and enthalpy, the values you need for demand-controlled ventilation. The VAV-Compact template reads airflow and damper position, and accepts setpoints for pressure-independent VAV systems.
All 17 Belimo templates are free to browse. Import one with a click into your ModbusCloud portal to read live hydronic or air data within minutes, no digging through Belimo datasheets for register offsets.
What you can read out
- Volumetric flow and delta-T per valve
- Valve and actuator position feedback
- CO2, humidity and dew point
- Airflow and damper position
- Fault and override status
Typical installations
- Hydronic heating and cooling circuits in commercial buildings
- Demand-controlled ventilation with CO2 room sensors
- Pressure-independent VAV systems in office HVAC
Want to see how it works?







