HVAC systems at all your sites in one overview
Monitor ventilation, cooling and heating in offices, shops and schools remotely. If a fault comes up, you get an email.

A gateway reads temperatures, setpoints and fault codes
One gateway per building reads the controllers over Modbus RTU (RS485) or Modbus TCP.
For each site you see every system, with live values such as supply temperature, setpoint and fan speed. If a fault code comes up or a gateway goes offline, you get an email.

- Daikin RTD-NETRS485, address 1Room22.4 °C
Setpoint21.0 °C - Belimo VAV-CompactRS485, address 2Airflow640 m³/h
What you can do for your clients
All sites on one map
Offices, shops and schools sit in one portal, even when every building has a different brand. The map shows whether everything is running at each site.
Hear about faults sooner
Set an alert on a fault code, a room temperature above 26 °C or a gateway that goes offline. The email often arrives before the tenant complains.
Back up your maintenance contracts
The portal keeps 365 days of history per register. With a PDF report you show your client how the installation performs.
Change setpoints remotely
If a setpoint is wrong, change it in the portal by writing the register. You don't have to go on site.
Templates for air conditioning, ventilation and control valves
These air conditioning interfaces, air handling units, valves and thermostats have a template ready, so the scan recognises them.
If your controller is not listed, we build the template for free as soon as we have the register data. You can also set up the registers yourself.
Browse the library| Manufacturer | Template | Modbus | Status |
|---|---|---|---|
| Daikin | Daikin RTD-NET Module | RTU (RS485) | Template ready |
| Toshiba | FDP3-MODBUS Interface | RTU (RS485) | Template ready |
| LG | LG PMBUSB00A Modbus Gateway | RTU (RS485) | Template ready |
| Gree | GMV (VRF) Gree | RTU (RS485) | Template ready |
| Belimo | Belimo VAV-Compact Modbus RTU | RTU (RS485) | Template ready |
| Siemens | Siemens RDF302 | RTU (RS485) | Template ready |
| Hoval | Hoval Ventilation | RTU (RS485) | Template ready |
| Systemair | Systemair SAVE VTR | RTU (RS485) | Template ready |
| Komfovent | Komfovent DOMEKT C6M | TCP (network) | Template ready |
Price per gateway, annual or lifetime
Gateway
€295 one-off
€275 from 10 units, €249 from 25, quote from 50
Portal
€149 per year
Including 4G data up to 30 MB per month
€495 one-off
4G data with a lifetime licence
Only when 4G is used
€1 per month
€95 for ten years
All prices excl. VAT. White label customer portal included. All prices
100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.
Want to see how it works?








