HVAC systems at all your sites in one overview

Monitor ventilation, cooling and heating in offices, shops and schools remotely. If a fault comes up, you get an email.

A gateway reads temperatures, setpoints and fault codes

One gateway per building reads the controllers over Modbus RTU (RS485) or Modbus TCP.

For each site you see every system, with live values such as supply temperature, setpoint and fan speed. If a fault code comes up or a gateway goes offline, you get an email.

What you can do for your clients

All sites on one map

Offices, shops and schools sit in one portal, even when every building has a different brand. The map shows whether everything is running at each site.

Hear about faults sooner

Set an alert on a fault code, a room temperature above 26 °C or a gateway that goes offline. The email often arrives before the tenant complains.

Back up your maintenance contracts

The portal keeps 365 days of history per register. With a PDF report you show your client how the installation performs.

Change setpoints remotely

If a setpoint is wrong, change it in the portal by writing the register. You don't have to go on site.

Every building has its own system, often from another brand

  • Air handling unit in fault

    The Monday complaint

    The tenant calls at 08:40: ‘It's 27 degrees on the second floor.’ The air handling unit has been in fault since Friday evening, and nobody knew.

  • Half-termHeating at 21 °C

    The empty school

    During the autumn half-term, the classrooms are heated to 21 °C. The schedule is still set to school days, and nobody notices.

  • 3 buildingsNo overall view

    Three buildings, three interfaces

    The office has Siemens, the shop Honeywell and the school Belimo. If you want to know how an installation is running, you drive there.

Templates for air conditioning, ventilation and control valves

These air conditioning interfaces, air handling units, valves and thermostats have a template ready, so the scan recognises them.

If your controller is not listed, we build the template for free as soon as we have the register data. You can also set up the registers yourself.

Browse the library
ManufacturerTemplateModbusStatus
DaikinDaikin RTD-NET ModuleRTU (RS485)Template ready
ToshibaFDP3-MODBUS InterfaceRTU (RS485)Template ready
LGLG PMBUSB00A Modbus GatewayRTU (RS485)Template ready
GreeGMV (VRF) GreeRTU (RS485)Template ready
BelimoBelimo VAV-Compact Modbus RTURTU (RS485)Template ready
SiemensSiemens RDF302RTU (RS485)Template ready
HovalHoval VentilationRTU (RS485)Template ready
SystemairSystemair SAVE VTRRTU (RS485)Template ready
KomfoventKomfovent DOMEKT C6MTCP (network)Template ready

Connect a building in three steps

  1. Connect

    Connect the controllers over RS485 with two wires, A and B, or over the building network.

  2. Scan

    Enter the serial number in the portal and start a scan. The gateway recognises the devices that are in the library.

  3. Monitor

    See temperatures, setpoints and fault codes per building. Set up alerts, for example on a room temperature above 26 °C.

Price per gateway, annual or lifetime

Gateway

€295 one-off

€275 from 10 units, €249 from 25, quote from 50

Portal

€149 per year

Including 4G data up to 30 MB per month

or

€495 one-off

4G data with a lifetime licence

Only when 4G is used

€1 per month

or

€95 for ten years

All prices excl. VAT. White label customer portal included. All prices

Order your first gateway

100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

Want to see how it works?

Engineer in a hard hat and mask checking the air handling units on a commercial roof