Monitor pumps, compressors and cooling systems remotely
For factories, swimming pools and data centres, without a SCADA package.

Pressure, temperature, flow and fault codes in one portal
At each installation a gateway reads the registers over Modbus RTU (RS485) or Modbus TCP.
See live values and 365 days of history per register. If a value crosses the threshold you set, you get an email.

- ABB ACS880RS485, address 1Speed1,460 rpm
Current32.6 A - Janitza UMG 604Network, Modbus TCPP48.2 kW
What maintenance teams use it for
Early detection
You get an email when a value crosses a threshold, a device stops or it reports a fault code. Automatic monitoring also reports a value that gets stuck.
Monitoring without a SCADA package
There is no server on site. The gateway makes the outbound connection itself, so your IT team does not need to open any ports.
Monitor remotely
View live values and trends in the browser, at the office or on the road.
Energy per machine
An energy meter per machine or hall shows where the energy goes. Export readings as CSV.
Equipment that must not fail, but isn't monitored
Compressor tripped on temperature
The compressed air goes down
At 02:10 the compressor trips on high temperature. The line stops, and the on-call engineer hears about it from the shift supervisor.
Cooling waterSupply temperature rising
The cooling that can't keep up
The cooling water supply temperature creeps up over a week. Only when a machine trips does anyone look at the cooling system.
Morning roundOne reading a day
The daily round
Every morning an engineer walks past the pumps and writes down pressure and temperature. What happens at night is recorded nowhere.
Templates for industrial installations
These drives, energy meters, pumps and sensors have a template ready, so the scan recognises them.
One RS485 line takes up to 32 devices. For a compressor or another device without a template, we build one for free as soon as we have the register data. You can also set up the registers yourself.
Browse the library| Manufacturer | Template | Modbus | Status |
|---|---|---|---|
| Danfoss | Danfoss VLT AutomationDrive FC 302 Option Modules | RTU (RS485) | Template ready |
| ABB | ABB ACS880 Option Modules | RTU (RS485) | Template ready |
| Siemens | Siemens SINAMICS G120X | RTU (RS485) | Template ready |
| Vacon | Vacon 100 | RTU (RS485) | Template ready |
| Janitza | Janitza UMG604 | TCP (network) | Template ready |
| Eastron | Eastron SDM630 Series | RTU (RS485) | Template ready |
| Grundfos | Grundfos CIM 200 | RTU (RS485) | Template ready |
| Krohne | Krohne IFC 050 | RTU (RS485) | Template ready |
| E+E Elektronik | E+E Elektronik EE600 - Differential Pressure Sensor | RTU (RS485) | Template ready |
Connect an installation in three steps
Connect
Connect the devices over RS485 with two wires, A and B, or over the network with Modbus TCP.
Scan
Enter the serial number in the portal and start a scan. The gateway searches its RS485 bus and its own network.
Monitor
See pressure, temperature, flow and fault codes per installation. Set up alerts, for example on a fault code not equal to 0.
Price per gateway, annual or lifetime
Gateway
€295 one-off
€275 from 10 units, €249 from 25, quote from 50
Portal
€149 per year
Including 4G data up to 30 MB per month
€495 one-off
4G data with a lifetime licence
Only when 4G is used
€1 per month
€95 for ten years
All prices excl. VAT. White label customer portal included. All prices
100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.