Danfoss Modbus templates
All 25 available Danfoss templates for ModbusCloud.
Monitor Danfoss VLT frequency converters and refrigeration controllers over Modbus RTU in your portal.
- Templates
- 25
- Connection
- Modbus RTU
- Registers
- 28 to 1290 per template
- Compatible models
- AK-CC 350 (084B4165) · AK-CC25 Pro 084B4022 · AK-CC25 Pro 084B4023 · AK-CC55 Compact (084B4081) · AK-CC55 Multi Coil · 084B4084 · AK-CC55 Single Coil · AK-CC55 Single Coil UI · 084B4082 · 084B4083 · AK-RC 305W-SD (080Z5003) · EKC 202D1 (084B8554) with EKA 178A Modbus module · EKE 1C · EKE 1B · ERC 211 · ERC 213 · ERC 214 · GDA · GDC · GDH · GDHC · GDHF · Danfoss Gas Detection units in Basic, Premium and Heavy Duty versions · OP-MPAM005 · OP-MPAM015 · Danfoss Optyma iCO2 CO2 condensing units 4.6 kW MT and 20 kW MT / 10 kW LT with the iCO2 gateway, SW 1.0x · Optyma Plus Controller 084B8080 · Optyma Plus Controller 084B8180 · Danfoss Optyma Plus condensing units with the Optyma Plus controller, SW 3.10 to 3.7x · SonoMeter 40 · Axioma Qalcosonic E3 with Modbus RTU Slave Module · Axioma Qalcosonic E4 with Modbus RTU Slave Module · VLT AQUA Drive FC 202 · FC 302 · FC 301 (same parameter numbering, fewer parameters) · FC 360 · VLT AutomationDrive FC 360 · VLT HVAC Basic Drive FC 101 · VLT HVAC Drive FC 102 · VLT Micro Drive FC 51 · VLT Midi Drive FC 280, all power sizes · VLT Refrigeration Drive FC 103 · VLT Refrigeration Drive FC 103 1.1 to 90 kW · VLT Refrigeration Drive FC 103 110 to 800 kW · VLT Soft Starter MCD 500 (all MCD5 models) with MCD Modbus Module 175G9000
- Last updated
Danfoss templates
25 via Modbus RTU
Danfoss AK-CC 350Controls temperature, defrost and fans in refrigerated display cabinets and cold rooms.Modbus RTU118 read, 85 write
Danfoss AK-CC25 ProCase and cold room controller: temperatures, compressor, defrost, fans and alarms.Modbus RTU277 read, 203 write
Danfoss AK-CC55 CompactCase and cold room controller with electronic expansion valve, read and set over Modbus RTU.Modbus RTU46 read, 8 write
Danfoss AK-CC55 Multi CoilCase and room controller for up to three evaporators with electronic expansion valves.Modbus RTU81 read, 13 write
Danfoss AK-CC55 Single CoilCase and room controller for one evaporator with an electronic expansion valve.Modbus RTU69 read, 13 write
Danfoss AK-RC 305W-SDCold room controller for walk-in coolers and freezers: temperatures, relays, defrost and alarms.Modbus RTU112 read, 76 write
Danfoss EKC 202D1Refrigeration controller: air and defrost temperatures, alarms, setpoint and defrost control.Modbus RTU117 read, 81 write
Danfoss EKE 1CSuperheat controller for stepper motor expansion valves in refrigeration, air conditioning and heat pumps.Modbus RTU249 read, 210 write
Danfoss ERC 21xRefrigeration controller: temperatures, relay states, setpoints, alarm and defrost parameters over Modbus RTU.Modbus RTU80 read, 62 write
Danfoss Gas Detection UnitGas detection for machine rooms: gas values, alarms, errors and maintenance days per sensor.Modbus RTU97 read, 1 write
Danfoss Optyma iCO2 GatewayCO2 condensing unit gateway: pressures, temperatures, valve openings and alarms.Modbus RTU58 read, 7 write
Danfoss Optyma PlusCondensing unit controller for commercial refrigeration: pressures, temperatures, fan speed and alarms.Modbus RTU42 read, 7 write
Danfoss SonoMeter 40Ultrasonic heat and cooling meter for energy, power, flow, temperatures and volume in heating and cooling systems.Modbus RTU51 read, 6 write
Danfoss VLT AQUA Drive FC 202Frequency converter for pumps and blowers in water and wastewater, with built-in PID and pump control.Modbus RTU1290 read, 830 write
Danfoss VLT AQUA Drive FC 202 Option ModulesOption card parameters of the VLT AQUA Drive FC 202, as an addition to the drive template.Modbus RTU308 read, 229 write
Danfoss VLT AutomationDrive FC 302Frequency converter for industrial motors with readouts, alarms, status word and all drive parameters.Modbus RTU1172 read, 877 write
Danfoss VLT AutomationDrive FC 302 Option ModulesMotion control, option, safety and condition monitoring parameters of the FC 302, as an addition to the drive template.Modbus RTU589 read, 357 write
Danfoss VLT AutomationDrive FC 360General purpose frequency converter for conveyors, pumps, fans and machines with built-in Modbus RTU.Modbus RTU800 read, 682 write
Danfoss VLT HVAC Basic Drive FC 101HVAC frequency converter for fans, pumps and compressors, over built-in Modbus RTU.Modbus RTU455 read, 368 write
Danfoss VLT HVAC Drive FC 102Frequency converter for HVAC fans and pumps: motor readings, alarms, start and stop, speed reference and settings.Modbus RTU1232 read, 813 write
Danfoss VLT HVAC Drive FC 102 Option ModulesOption parameters of the VLT HVAC Drive FC 102, as an addition to the drive template.Modbus RTU300 read, 211 write
Danfoss VLT Micro Drive FC 51Compact frequency converter for small pumps, fans and conveyors, read and set over Modbus RTU.Modbus RTU298 read, 213 write
Danfoss VLT Midi Drive FC 280Frequency converter for pumps, fans and machines: motor data, alarms, control and all parameters.Modbus RTU638 read, 547 writeDanfoss VLT Refrigeration Drive FC 103Frequency converter for refrigeration compressors and condenser fans with pack control.Modbus RTU844 read, 686 write
Danfoss VLT Soft Starter MCD 500Soft starter for three-phase motors: state, trips, currents, power and start and stop.Modbus RTU27 read, 7 write
The scan recognises these devices
Connect them to RS485 or the network and start a scan in the portal.
Gateway
Portal
Incl. 4G data up to 30 MB per month
Excl. VAT. White label customer portal included. All prices
Order your first gateway100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

Danfoss makes the VLT frequency converters that drive pumps and fans in HVAC, water and industry, and the AK-CC and EKC controllers on refrigeration units. You meet them in plant rooms, pumping stations and supermarkets.
The gateway reads these devices over Modbus RTU on its RS485 port. Each template holds the registers of that model: motor values, status word, alarms and parameters. In the portal you see frequency, current and faults per device.
What you can read out
- Motor frequency, current and power
- Status word and active alarms
- Running hours of fans and motors
- Valve position on refrigeration controllers
Typical installations
- Pump and fan drives in HVAC plant rooms
- Pumping stations with VLT AQUA Drive converters
- Refrigerated cabinets and cold rooms in supermarkets
Want to see how it works?







