Danfoss VLT Refrigeration Drive FC 103

Frequency converter for refrigeration compressors and condenser fans with pack control.

The Danfoss VLT Refrigeration Drive FC 103 is a frequency converter that controls compressors, condenser fans and pumps in commercial and industrial refrigeration. This Modbus RTU template reads frequency, current, power, temperatures, suction pressure and alarms, and lets you start, stop and adjust speed and setpoints from ModbusCloud.

Protocol
Modbus RTU
Connection
RS485, 19200 baud
Registers
878, read and write
Brand
Danfoss
Key readings
Output frequency · Motor current · Power · Motor voltage · DC link voltage · Heatsink temperature · Suction pressure P0 · Alarm and warning words
Available commands
Start and stop · Speed reference · P0 setpoint · Setpoints 1 to 3 · Ramp times · Pack controller settings
Compatible models
VLT Refrigeration Drive FC 103 · VLT Refrigeration Drive FC 103 1.1 to 90 kW · VLT Refrigeration Drive FC 103 110 to 800 kW
Last updated

Registers (878)

844 read, 686 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
FrequencyHzRead
Motor CurrentARead
Power [kW]kWRead
Motor VoltageVRead
Speed [RPM]rpmRead
Torque [Nm]NmRead
Torque [%]%Read
DC Link VoltageVRead
Heatsink Temp.°CRead
Control Card Temp.°CRead
Motor Thermal%Read
Inverter Thermal%Read
ReferenceRead
Reference [%]%Read
Main Actual Value [%]%Read
FeedbackRead
Feedback 1Read
Feedback 2Read
Feedback 3Read
Discharge TemperatureRead
P0KRead
P0 SetpointKRead and write
P0 ReferenceKRead
Monitor 1 Pressure 1Read
Monitor 2 Pressure 2Read
Pack Capacity [%]%Read
Pack StatusRead
Compressor StatusRead
Lead CompressorRead
Relay StatusRead
Compressor ON TimehRead
Relay ON TimehRead
Alarm WordRead
Alarm Word 2Read
Warning WordRead
Warning Word 2Read
Ext. Status WordRead
Ext. Status Word 2Read
Maintenance WordRead
Ext. Status Word 3Read
Control WordRead
Status WordRead
Operating HourshRead
Running HourshRead
kWh CounterkWhRead
Power Up'sRead
Over Temp'sRead
Over Volt'sRead
Number of StartsRead
Fan Running HourshRead
Status Coil Control ReadyRead
Status Coil Drive ReadyRead
Status Coil Coasting Stop or Safety ClosedRead
Status Coil AlarmRead
Status Coil Bit 04Read
Status Coil Bit 05Read
Status Coil Bit 06Read
Status Coil WarningRead
Status Coil At ReferenceRead
Status Coil Auto ModeRead
Status Coil In Frequency RangeRead
Status Coil RunningRead
Status Coil Bit 12Read
Status Coil Voltage WarningRead
Status Coil Current LimitRead
Status Coil Thermal WarningRead
Actual Value Coil Bit 0Read
Actual Value Coil Bit 1Read
Actual Value Coil Bit 2Read
Actual Value Coil Bit 3Read
Actual Value Coil Bit 4Read
Actual Value Coil Bit 5Read
Actual Value Coil Bit 6Read
Actual Value Coil Bit 7Read
Actual Value Coil Bit 8Read
Actual Value Coil Bit 9Read
Actual Value Coil Bit 10Read
Actual Value Coil Bit 11Read
Actual Value Coil Bit 12Read
Actual Value Coil Bit 13Read
Actual Value Coil Bit 14Read
Actual Value Coil Bit 15Read
Bus Status WordRead
Main Actual ValueRead
Last Error CodeRead
Control Coil Preset Reference LSBWrite
Control Coil Preset Reference MSBWrite
Control Coil DC BrakeWrite
Control Coil Coast StopWrite
Control Coil Quick StopWrite
Control Coil Freeze FrequencyWrite
Control Coil Ramp Stop or StartWrite
Control Coil ResetWrite
Control Coil JogWrite
Control Coil Ramp 1 or 2Write
Control Coil Data ValidWrite
Control Coil Relay 1Write
Control Coil Relay 2Write
Control Coil Set-up LSBWrite
Control Coil Set-up MSBWrite
Control Coil ReversingWrite
Reference Coil Bit 0Write
Reference Coil Bit 1Write
Reference Coil Bit 2Write
Reference Coil Bit 3Write
Reference Coil Bit 4Write
Reference Coil Bit 5Write
Reference Coil Bit 6Write
Reference Coil Bit 7Write
Reference Coil Bit 8Write
Reference Coil Bit 9Write
Reference Coil Bit 10Write
Reference Coil Bit 11Write
Reference Coil Bit 12Write
Reference Coil Bit 13Write
Reference Coil Bit 14Write
Reference Coil Bit 15Write
Parameter Write ControlRead and write
Bus Control WordWrite
Bus ReferenceWrite
Array Index PointerRead and write
LanguageRead and write
Motor Speed UnitRead and write
Regional SettingsRead and write
Operating State at Power-upRead and write
Local Mode UnitRead and write
Active Set-upRead and write
Programming Set-upRead and write
This Set-up Linked toRead and write
Readout: Linked Set-upsRead and write
Readout: Prog. Set-ups / ChannelRead and write
Display Line 1.1 SmallRead and write
Display Line 1.2 SmallRead and write
Display Line 1.3 SmallRead and write
Display Line 2 LargeRead and write
Display Line 3 LargeRead and write
My Personal MenuRead and write
Custom Readout UnitRead and write
Custom Readout Min ValueRead and write
Custom Readout Max ValueRead and write
Display Text 1Read and write
Display Text 2Read and write
Display Text 3Read and write
[Hand On] Key on LCPRead and write
[Off] Key on LCPRead and write
[Auto On] Key on LCPRead and write
[Reset] Key on LCPRead and write
LCP CopyRead and write
Set-up CopyRead and write
Main Menu PasswordRead and write
Access to Main Menu w/o PasswordRead and write
Personal Menu PasswordRead and write
Access to Personal Menu w/o PasswordRead and write
Bus Password AccessRead and write
Set Date and TimeRead and write
Date FormatRead and write
Time FormatRead and write
DST/SummertimeRead and write
DST/Summertime StartRead and write
DST/Summertime EndRead and write
Clock FaultRead and write
Working DaysRead and write
Additional Working DaysRead and write
Additional Non-Working DaysRead and write
Date and Time ReadoutRead
Configuration ModeRead and write
Torque CharacteristicsRead and write
Clockwise DirectionRead and write
Motor ConstructionRead and write
Damping Gain%Read and write
Low Speed Filter Time Const.Read and write
High Speed Filter Time Const.Read and write
Voltage Filter Time Const.Read and write
Motor Power [kW]kWRead and write
Motor Power [HP]Read and write
Motor Voltage (1-22)Read and write
Motor FrequencyRead and write
Motor Current (1-24)Read and write
Motor Nominal SpeedRead and write
Motor Cont. Rated TorqueRead and write
Motor Rotation CheckRead and write
Automatic Motor Adaptation (AMA)Read and write
Stator Resistance (Rs)Read and write
Rotor Resistance (Rr)Read and write
Main Reactance (Xh)Read and write
Iron Loss Resistance (Rfe)Read and write
D-axis Inductance (Ld)Read and write
Q-axis Inductance (Lq)Read and write
Motor PolesRead and write
Back EMF at 1000 RPMRead and write
Motor Angle OffsetRead and write
D-axis Inductance Sat. (LdSat)Read and write
Q-axis Inductance Sat. (LqSat)Read and write
Position Detection Gain%Read and write
Torque CalibrationRead and write
Inductance Sat. PointRead and write
Motor Magnetisation at Zero Speed%Read and write
Min Speed Normal Magnetising [RPM]rpmRead and write
Min Speed Normal Magnetising [Hz]HzRead and write
Flying Start Test Pulses CurrentRead and write
Flying Start Test Pulses FrequencyRead and write
Low Speed Load Compensation%Read and write
High Speed Load Compensation%Read and write
Slip Compensation%Read and write
Slip Compensation Time ConstantRead and write
Resonance Dampening%Read and write
Resonance Dampening Time ConstantmsRead and write
Min. Current at Low SpeedRead and write
PM Start ModeRead and write
Start DelaysRead and write
Start FunctionRead and write
Flying StartRead and write
Start Speed [RPM]rpmRead and write
Start Speed [Hz]HzRead and write
Start CurrentARead and write
Compressor Start Max Speed [RPM]rpmRead and write
Compressor Start Max Speed [Hz]HzRead and write
Compressor Start Max Time to TripsRead and write
Function at StopRead and write
Min Speed for Function at Stop [RPM]rpmRead and write
Min Speed for Function at Stop [Hz]HzRead and write
Compressor Min. Speed for Trip [RPM]rpmRead and write
Compressor Min. Speed for Trip [Hz]HzRead and write
Motor Thermal ProtectionRead and write
Motor External FanRead and write
Thermistor SourceRead and write
DC Hold/Preheat Current%Read and write
DC Brake Current%Read and write
DC Braking TimesRead and write
DC Brake Cut In Speed [RPM]rpmRead and write
DC Brake Cut In Speed [Hz]HzRead and write
Parking Current%Read and write
Parking TimesRead and write
Brake FunctionRead and write
AC Brake Max. Current%Read and write
Over-voltage ControlRead and write
Minimum ReferenceRead and write
Maximum ReferenceRead and write
Reference FunctionRead and write
Preset Reference%Read and write
Jog Speed [Hz]HzRead and write
Reference SiteRead and write
Preset Relative Reference%Read and write
Reference 1 SourceRead and write
Reference 2 SourceRead and write
Reference 3 SourceRead and write
Jog Speed [RPM]rpmRead and write
Ramp 1 Ramp Up TimeRead and write
Ramp 1 Ramp Down TimeRead and write
Ramp 2 Ramp Up TimeRead and write
Ramp 2 Ramp Down TimeRead and write
Jog Ramp TimeRead and write
Quick Stop Ramp TimeRead and write
Starting Ramp Up TimeRead and write
Step Size%Read and write
Ramp TimesRead and write
Power RestoreRead and write
Maximum Limit%Read and write
Minimum Limit%Read and write
Ramp DelayRead and write
Motor Speed DirectionRead and write
Motor Speed Low Limit [RPM]rpmRead and write
Motor Speed Low Limit [Hz]HzRead and write
Motor Speed High Limit [RPM]rpmRead and write
Motor Speed High Limit [Hz]HzRead and write
Torque Limit Motor Mode%Read and write
Torque Limit Generator Mode%Read and write
Current LimitRead and write
Max Output FrequencyRead and write
Warning Current LowARead and write
Warning Current HighRead and write
Warning Speed LowrpmRead and write
Warning Speed HighRead and write
Warning Reference LowRead and write
Warning Reference HighRead and write
Warning Feedback LowRead and write
Warning Feedback HighRead and write
Missing Motor Phase FunctionRead and write
Motor Check At StartRead and write
Bypass Speed From [RPM]rpmRead and write
Bypass Speed From [Hz]HzRead and write
Bypass Speed To [RPM]rpmRead and write
Bypass Speed To [Hz]HzRead and write
Semi-Auto Bypass Set-upRead and write
Digital I/O ModeRead and write
Terminal 27 ModeRead and write
Terminal 29 ModeRead and write
Terminal 18 Digital InputRead and write
Terminal 19 Digital InputRead and write
Terminal 27 Digital InputRead and write
Terminal 29 Digital InputRead and write
Terminal 32 Digital InputRead and write
Terminal 33 Digital InputRead and write
Terminal X30/2 Digital InputRead and write
Terminal X30/3 Digital InputRead and write
Terminal X30/4 Digital InputRead and write
Terminal 37 Safe StopRead and write
Terminal X46/1 Digital InputRead and write
Terminal X46/3 Digital InputRead and write
Terminal X46/5 Digital InputRead and write
Terminal X46/7 Digital InputRead and write
Terminal X46/9 Digital InputRead and write
Terminal X46/11 Digital InputRead and write
Terminal X46/13 Digital InputRead and write
Terminal 27 Digital OutputRead and write
Terminal 29 Digital OutputRead and write
Term X30/6 Digi Out (MCB 101)Read and write
Term X30/7 Digi Out (MCB 101)Read and write
Function RelayRead and write
On Delay, RelaysRead and write
Off Delay, RelaysRead and write
Term. 29 Low FrequencyHzRead and write
Term. 29 High FrequencyHzRead and write
Term. 29 Low Ref./Feedb. ValueRead and write
Term. 29 High Ref./Feedb. ValueRead and write
Pulse Filter Time Constant #29msRead and write
Term. 33 Low FrequencyHzRead and write
Term. 33 High FrequencyHzRead and write
Term. 33 Low Ref./Feedb. ValueRead and write
Term. 33 High Ref./Feedb. ValueRead and write
Pulse Filter Time Constant #33msRead and write
Terminal 27 Pulse Output VariableRead and write
Pulse Output Max Freq #27HzRead and write
Terminal 29 Pulse Output VariableRead and write
Pulse Output Max Freq #29HzRead and write
Terminal X30/6 Pulse Output VariableRead and write
Pulse Output Max Freq #X30/6HzRead and write
AHF Cap Reconnect DelaysRead and write
Digital & Relay Bus ControlRead and write
Pulse Out #27 Bus Control%Read and write
Pulse Out #27 Timeout Preset%Read and write
Pulse Out #29 Bus Control%Read and write
Pulse Out #29 Timeout Preset%Read and write
Pulse Out #X30/6 Bus Control%Read and write
Pulse Out #X30/6 Timeout Preset%Read and write
Live Zero Timeout TimesRead and write
Live Zero Timeout FunctionRead and write
Terminal 53 Low VoltageVRead and write
Terminal 53 High VoltageVRead and write
Terminal 53 Low CurrentmARead and write
Terminal 53 High CurrentmARead and write
Terminal 53 Low Ref./Feedb. ValueRead and write
Terminal 53 High Ref./Feedb. ValueRead and write
Terminal 53 Filter Time ConstantsRead and write
Terminal 53 Live ZeroRead and write
Terminal 54 Low VoltageVRead and write
Terminal 54 High VoltageVRead and write
Terminal 54 Low CurrentmARead and write
Terminal 54 High CurrentmARead and write
Terminal 54 Low Ref./Feedb. ValueRead and write
Terminal 54 High Ref./Feedb. ValueRead and write
Terminal 54 Filter Time ConstantsRead and write
Terminal 54 Live ZeroRead and write
Terminal X30/11 Low VoltageVRead and write
Terminal X30/11 High VoltageVRead and write
Term. X30/11 Low Ref./Feedb. ValueRead and write
Term. X30/11 High Ref./Feedb. ValueRead and write
Term. X30/11 Filter Time ConstantsRead and write
Term. X30/11 Live ZeroRead and write
Terminal X30/12 Low VoltageVRead and write
Terminal X30/12 High VoltageVRead and write
Term. X30/12 Low Ref./Feedb. ValueRead and write
Term. X30/12 High Ref./Feedb. ValueRead and write
Term. X30/12 Filter Time ConstantsRead and write
Term. X30/12 Live ZeroRead and write
Terminal 42 OutputRead and write
Terminal 42 Output Min Scale%Read and write
Terminal 42 Output Max Scale%Read and write
Terminal 42 Output Bus Control%Read and write
Terminal 42 Output Timeout Preset%Read and write
Terminal X30/8 OutputRead and write
Terminal X30/8 Min. Scale%Read and write
Terminal X30/8 Max. Scale%Read and write
Terminal X30/8 Output Bus Control%Read and write
Terminal X30/8 Output Timeout Preset%Read and write
Terminal X45/1 OutputRead and write
Terminal X45/1 Min. Scale%Read and write
Terminal X45/1 Max. Scale%Read and write
Terminal X45/1 Bus Control%Read and write
Terminal X45/1 Output Timeout Preset%Read and write
Terminal X45/3 OutputRead and write
Terminal X45/3 Min. Scale%Read and write
Terminal X45/3 Max. Scale%Read and write
Terminal X45/3 Bus Control%Read and write
Terminal X45/3 Output Timeout Preset%Read and write
Control SiteRead and write
Control SourceRead and write
Control Timeout TimeRead and write
Control Timeout FunctionRead and write
End-of-Timeout FunctionRead and write
Reset Control TimeoutRead and write
Diagnosis TriggerRead and write
Control ProfileRead and write
Configurable Status Word STWRead and write
Store Data ValuesRead and write
ProtocolRead and write
AddressRead and write
Baud RateRead and write
Parity / Stop BitsRead and write
Minimum Response DelaymsRead and write
Maximum Response DelayRead and write
Maximum Inter-Char DelayRead and write
Telegram SelectionRead and write
PCD Write ConfigurationRead and write
PCD Read ConfigurationRead and write
BTM Transaction CommandRead and write
BTM Transaction StatusRead and write
BTM TimeoutsRead and write
Coasting SelectRead and write
DC Brake SelectRead and write
Start SelectRead and write
Reversing SelectRead and write
Set-up SelectRead and write
Preset Reference SelectRead and write
Bus Message CountRead and write
Bus Error CountRead and write
Slave Message CountRead and write
Slave Error CountRead and write
Bus Jog 1 SpeedrpmRead and write
Bus Jog 2 SpeedRead and write
Bus Feedback 1Read and write
Bus Feedback 2Read and write
Bus Feedback 3Read and write
Store Data Values (11-21)Read and write
VLT Network AddressRead and write
AK Service PinRead and write
Alarm TextRead
Alarm StatusRead
SL Controller ModeRead and write
Start EventRead and write
Stop EventRead and write
Reset SLCRead and write
Comparator OperandRead and write
Comparator OperatorRead and write
Comparator ValueRead and write
SL Controller TimerRead and write
Logic Rule Boolean 1Read and write
Logic Rule Operator 1Read and write
Logic Rule Boolean 2Read and write
Logic Rule Operator 2Read and write
Logic Rule Boolean 3Read and write
SL Controller EventRead and write
SL Controller ActionRead and write
Alert TriggerRead and write
Alert ActionRead and write
Alert TextRead and write
Alert Alarm WordRead
Alert Warning WordRead
Alert Status WordRead
Switching PatternRead and write
Switching FrequencyRead and write
OvermodulationRead and write
PWM RandomRead and write
Mains FailureRead and write
Mains Voltage at Mains FaultRead and write
Function at Mains ImbalanceRead and write
Kin. Backup Gain%Read and write
Reset ModeRead and write
Automatic Restart TimesRead and write
Operation ModeRead and write
Trip Delay at Torque LimitsRead and write
Trip Delay at Inverter FaultRead and write
Production SettingsRead and write
Service CodeRead and write
Current Lim Ctrl, Proportional Gain%Read and write
Current Lim Ctrl, Integration TimeRead and write
VT Level%Read and write
AEO Minimum MagnetisationRead and write
Minimum AEO FrequencyRead and write
Motor CosphiRead and write
RFI FilterRead and write
DC Link CompensationRead and write
Fan ControlRead and write
Fan MonitorRead and write
Output FilterRead and write
Actual Number of Inverter UnitsRead
Function at Over TemperatureRead and write
Function at Inverter OverloadRead and write
Inv. Overload Derate Current%Read and write
Option Supplied By External 24VDCRead and write
Option DetectionRead and write
Fault LevelRead and write
Reset kWh CounterRead and write
Reset Running Hours CounterRead and write
Logging SourceRead and write
Logging IntervalRead and write
Trigger EventRead and write
Logging ModeRead and write
Samples Before TriggerRead and write
Historic Log: EventRead
Historic Log: ValueRead
Historic Log: TimemsRead
Historic Log: Date and TimeRead
Alarm Log: Error CodeRead
Alarm Log: ValueRead
Alarm Log: TimesRead
Alarm Log: Date and TimeRead
Alarm Log: StatusRead
Alarm Log: Alarm TextRead
Preset Fan Running HourshRead and write
Custom ReadoutRead
Power [hp]Read
Frequency [%]%Read
Calibrated Stator ResistanceΩRead
System Temp.°CRead
Brake Energy /skWRead
Brake Energy /2 MinkWRead
Inv. Nom. CurrentRead
Inv. Max. CurrentRead
SL Controller StateRead
Logging Buffer FullRead
LCP Bottom StatuslineRead
Current Fault SourceRead
External ReferenceRead
Digi Pot ReferenceRead
Digital InputRead
Terminal 53 Switch SettingRead
Analog Input 53Read
Terminal 54 Switch SettingRead
Analog Input 54Read
Analog Output 42 [mA]mARead
Digital Output [bin]Read
Pulse Input #29 [Hz]HzRead
Pulse Input #33 [Hz]HzRead
Pulse Output #27 [Hz]HzRead
Pulse Output #29 [Hz]HzRead
Relay Output [bin]Read
Counter ARead
Counter BRead
Analog In X30/11Read
Analog In X30/12Read
Analog Out X30/8 [mA]mARead
Analog Out X45/1 [mA]mARead
Analog Out X45/3 [mA]mARead
Fieldbus CTW 1Read
Fieldbus REF 1Read
Comm. Option STWRead
FC Port CTW 1Read
FC Port REF 1Read
Maintenance Log: ItemRead
Maintenance Log: ActionRead
Maintenance Log: TimesRead
Maintenance Log: Date and TimeRead
Analog Input X42/1Read
Analog Input X42/3Read
Analog Input X42/5Read
Analog Out X42/7 [V]VRead
Analog Out X42/9 [V]VRead
Analog Out X42/11 [V]VRead
Air Pressure to Flow Air FlowRead
Digital Input 2Read
Mains VoltageVRead
Mains FrequencyHzRead
Mains Imbalance%Read
Rectifier DC Volt.VRead
Feedback 1 SourceRead and write
Feedback 1 ConversionRead and write
Feedback 1 Source UnitRead and write
Feedback 2 SourceRead and write
Feedback 2 ConversionRead and write
Feedback 2 Source UnitRead and write
Feedback 3 SourceRead and write
Feedback 3 ConversionRead and write
Feedback 3 Source UnitRead and write
Reference/Feedback UnitRead and write
Feedback FunctionRead and write
Setpoint 1Read and write
Setpoint 2Read and write
Setpoint 3Read and write
Setpoint TypeRead and write
RefrigerantRead and write
User Defined Refrigerant A1Read and write
User Defined Refrigerant A2Read and write
User Defined Refrigerant A3Read and write
Thermostat/Pressostat FunctionRead and write
Cut-out ValueRead and write
Cut-in ValueRead and write
Closed Loop TypeRead and write
PID PerformanceRead and write
PID Output ChangeRead and write
Minimum Feedback LevelRead and write
Maximum Feedback LevelRead and write
PID AutotuningRead and write
PID Normal/ Inverse ControlRead and write
PID Start Speed [RPM]rpmRead and write
PID Start Speed [Hz]HzRead and write
On Reference Bandwidth%Read and write
PID Anti WindupRead and write
PID Proportional GainRead and write
PID Integral TimesRead and write
PID Differentiation TimesRead and write
PID Diff. Gain LimitRead and write
Ext. Loop Closed Loop TypeRead and write
Ext. Loop PID PerformanceRead and write
Ext. Loop PID Output ChangeRead and write
Ext. Loop Minimum Feedback LevelRead and write
Ext. Loop Maximum Feedback LevelRead and write
Ext. Loop PID AutotuningRead and write
Ext. 1 Ref./Feedback UnitRead and write
Ext. 1 Minimum ReferenceRead and write
Ext. 1 Maximum ReferenceRead and write
Ext. 1 Reference SourceRead and write
Ext. 1 Feedback SourceRead and write
Ext. 1 SetpointRead and write
Ext. 1 PID ConversionRead and write
Ext. 1 ReferenceRead and write
Ext. 1 FeedbackRead and write
Ext. 1 Output [%]%Read and write
Ext. 1 Normal/Inverse ControlRead and write
Ext. 1 Proportional GainRead and write
Ext. 1 Integral TimesRead and write
Ext. 1 Differentation TimesRead and write
Ext. 1 Dif. Gain LimitRead and write
Ext. 2 Ref./Feedback UnitRead and write
Ext. 2 Minimum ReferenceRead and write
Ext. 2 Maximum ReferenceRead and write
Ext. 2 Reference SourceRead and write
Ext. 2 Feedback SourceRead and write
Ext. 2 SetpointRead and write
Ext. 2 PID ConversionRead and write
Ext. 2 ReferenceRead and write
Ext. 2 FeedbackRead and write
Ext. 2 Output [%]%Read and write
Ext. 2 Normal/Inverse ControlRead and write
Ext. 2 Proportional GainRead and write
Ext. 2 Integral TimesRead and write
Ext. 2 Differentation TimesRead and write
Ext. 2 Dif. Gain LimitRead and write
Ext. 3 Ref./Feedback UnitRead and write
Ext. 3 Minimum ReferenceRead and write
Ext. 3 Maximum ReferenceRead and write
Ext. 3 Reference SourceRead and write
Ext. 3 Feedback SourceRead and write
Ext. 3 SetpointRead and write
Ext. 3 PID ConversionRead and write
Ext. 3 ReferenceRead and write
Ext. 3 FeedbackRead and write
Ext. 3 Output [%]%Read and write
Ext. 3 Normal/Inverse ControlRead and write
Ext. 3 Proportional GainRead and write
Ext. 3 Integral TimesRead and write
Ext. 3 Differentation TimesRead and write
Ext. 3 Dif. Gain LimitRead and write
Ext. Loop RefrigerantRead and write
Ext. Loop User Defined Refrigerant A1Read and write
Ext. Loop User Defined Refrigerant A2Read and write
Ext. Loop User Defined Refrigerant A3Read and write
External Interlock DelaysRead and write
Air Pressure to Flow Signal SourceRead and write
Air Pressure to Flow Fan K-factorRead and write
Air Pressure to Flow Air DensityRead and write
Air Pressure to Flow Fan Flow UnitRead and write
Low Power Auto Set-upRead and write
Low Power DetectionRead and write
Low Speed DetectionRead and write
No-Flow FunctionRead and write
No-Flow DelaysRead and write
Dry Pump FunctionRead and write
Dry Pump DelaysRead and write
No-Flow PowerkWRead and write
Power Correction Factor%Read and write
Low Speed [RPM]rpmRead and write
Low Speed [Hz]HzRead and write
Low Speed Power [kW]kWRead and write
Low Speed Power [HP]Read and write
High Speed [RPM]rpmRead and write
High Speed [Hz]HzRead and write
High Speed Power [kW]kWRead and write
High Speed Power [HP]Read and write
Minimum Run TimesRead and write
Minimum Sleep TimesRead and write
Wake-up Speed [RPM]rpmRead and write
Wake-up Speed [Hz]HzRead and write
Wake-up Ref./FB Difference%Read and write
Setpoint Boost%Read and write
Maximum Boost TimesRead and write
End of Curve FunctionRead and write
End of Curve DelaysRead and write
Broken Belt FunctionRead and write
Broken Belt Torque%Read and write
Broken Belt DelaysRead and write
Short Cycle ProtectionRead and write
Interval between StartssRead and write
Minimum Run Time (22-77)sRead and write
Minimum Run Time OverrideRead and write
Minimum Run Time Override ValueRead and write
Flow CompensationRead and write
Square-linear Curve Approximation%Read and write
Work Point CalculationRead and write
Speed at No-Flow [RPM]rpmRead and write
Speed at No-Flow [Hz]HzRead and write
Speed at Design Point [RPM]rpmRead and write
Speed at Design Point [Hz]HzRead and write
Pressure at No-Flow SpeedRead and write
Pressure at Rated SpeedRead and write
Flow at Design PointRead and write
Flow at Rated SpeedRead and write
ON TimeRead and write
ON ActionRead and write
OFF TimeRead and write
OFF ActionRead and write
OccurrenceRead and write
Maintenance ItemRead and write
Maintenance ActionRead and write
Maintenance Time BaseRead and write
Maintenance Time IntervalhRead and write
Maintenance Date and TimeRead and write
Reset Maintenance WordRead and write
Maintenance TextRead and write
Energy Log ResolutionRead and write
Period StartRead and write
Energy LogRead
Reset Energy LogRead and write
Trend VariableRead and write
Continuous Bin DataRead
Timed Bin DataRead
Timed Period StartRead and write
Timed Period StopRead and write
Minimum Bin ValueRead and write
Reset Continuous Bin DataRead and write
Reset Timed Bin DataRead and write
Power Reference Factor%Read and write
Energy CostRead and write
InvestmentRead and write
Energy SavingskWhRead
Cost SavingsRead
Pack ControllerRead and write
Motor StartRead and write
Pump CyclingRead and write
Fixed Lead CompressorRead and write
Number of CompressorsRead and write
Neutral ZoneRead and write
+ ZoneRead and write
- ZoneRead and write
Fixed Speed Neutral ZoneRead and write
+ Zone DelaysRead and write
- Zone DelaysRead and write
++ Zone DelaysRead and write
-- Zone DelaysRead and write
Override Bandwidth Ramp TimeRead and write
Destage At No-FlowRead and write
Stage FunctionRead and write
Stage Function TimesRead and write
Destage FunctionRead and write
Destage Function TimesRead and write
Staging ThresholdRead and write
Destaging ThresholdRead and write
Staging Speed [RPM]rpmRead and write
Staging Speed [Hz]HzRead and write
Destaging Speed [RPM]rpmRead and write
Destaging Speed [Hz]HzRead and write
Lead Pump AlternationRead and write
Alternation EventRead and write
Alternation Time IntervalhRead and write
Alternation Timer ValueRead
Alternation Predefined TimeRead and write
Alternate if Load < 50%Read and write
Staging Mode at AlternationRead and write
Run Next Pump DelaysRead and write
Run on Mains DelaysRead and write
Reset Relay CountersRead and write
Inverse InterlockRead
Compressor InterlockRead and write
Manual AlternationRead and write
Terminal X42/1 ModeRead and write
Terminal X42/3 ModeRead and write
Terminal X42/5 ModeRead and write
Terminal X42/1 Low VoltageVRead and write
Terminal X42/1 High VoltageVRead and write
Term. X42/1 Low Ref./Feedb. ValueRead and write
Term. X42/1 High Ref./Feedb. ValueRead and write
Term. X42/1 Filter Time ConstantsRead and write
Term. X42/1 Live ZeroRead and write
Terminal X42/3 Low VoltageVRead and write
Terminal X42/3 High VoltageVRead and write
Term. X42/3 Low Ref./Feedb. ValueRead and write
Term. X42/3 High Ref./Feedb. ValueRead and write
Term. X42/3 Filter Time ConstantsRead and write
Term. X42/3 Live ZeroRead and write
Terminal X42/5 Low VoltageVRead and write
Terminal X42/5 High VoltageVRead and write
Term. X42/5 Low Ref./Feedb. ValueRead and write
Term. X42/5 High Ref./Feedb. ValueRead and write
Term. X42/5 Filter Time ConstantsRead and write
Term. X42/5 Live ZeroRead and write
Terminal X42/7 OutputRead and write
Terminal X42/7 Min. Scale%Read and write
Terminal X42/7 Max. Scale%Read and write
Terminal X42/7 Bus Control%Read and write
Terminal X42/7 Timeout Preset%Read and write
Terminal X42/9 OutputRead and write
Terminal X42/9 Min. Scale%Read and write
Terminal X42/9 Max. Scale%Read and write
Terminal X42/9 Bus Control%Read and write
Terminal X42/9 Timeout Preset%Read and write
Terminal X42/11 OutputRead and write
Terminal X42/11 Min. Scale%Read and write
Terminal X42/11 Max. Scale%Read and write
Terminal X42/11 Bus Control%Read and write
Terminal X42/11 Timeout Preset%Read and write
Oil Return ManagementRead and write
Low Speed Running TimeminRead and write
Fixed Boost IntervalhRead and write
Boost DurationsRead and write
Adequate Oil Return Speed [RPM]rpmRead and write
Adequate Oil Return Speed [Hz]HzRead and write
Oil Boost Speed [RPM]rpmRead and write
Oil Boost Speed [Hz]HzRead and write
Cancel Oil Boost at Low FeedbackRead and write
Cancel Oil Boost at High FeedbackRead and write
Temperature SourceRead and write
Temperature UnitRead and write
Warning LevelRead and write
Warning ActionRead and write
Emergency LevelRead and write
Day/Night Bus IndicatorRead and write
Enable Day/Night Via BusRead and write
Night SetbackRead and write
Night Speed Drop [RPM]rpmRead and write
Night Speed Drop OverrideRead and write
Night Speed Drop [Hz]HzRead and write
dP0 OffsetKRead and write
P0 Minimum ReferenceKRead and write
P0 Maximum ReferenceKRead and write
Most Loaded ControllerRead
Injection OnRead and write
Delayed Compressor StartRead and write
Pre/Post Lube FunctionRead and write
Pre Lube TimesRead and write
Post Lube TimesRead and write
Locked Rotor ProtectionRead and write
Locked Rotor Detection Time [s]sRead and write
Monitor 1 Pressure TransmitterRead and write
Monitor 1 Pressure ConversionRead and write
Monitor 1 Pressure Source UnitRead and write
Monitor 1 Temperature UnitRead and write
Monitor 1 High Pres. StopRead and write
Monitor 1 High Pres. StartRead and write
Monitor 1 Low Pres. StopRead and write
Monitor 1 Low Pres. StartRead and write
Monitor 2 Pressure TransmitterRead and write
Monitor 2 Pressure ConversionRead and write
Monitor 2 Pressure Source UnitRead and write
Monitor 2 Temperature UnitRead and write
Monitor 2 High Pres. StopRead and write
Monitor 2 High Pres. StartRead and write
Monitor 2 Low Pres. StopRead and write
Monitor 2 Low Pres. StartRead and write
Monitor 2 Pressure Stop Ramp TimeRead and write
Heat Sink Fan ModeRead and write
FC TypeRead
Power SectionRead
VoltageRead
Software VersionRead
Ordered Typecode StringRead
Actual Typecode StringRead
Frequency Converter Ordering NoRead
Power Card Ordering NoRead
LCP Id NoRead
SW ID Control CardRead
SW ID Power CardRead
Frequency Converter Serial NumberRead
Power Card Serial NumberRead
Option MountedRead
Option SW VersionRead
Option Ordering NoRead
Option Serial NoRead
Option in Slot ARead
Slot A Option SW VersionRead
Option in Slot BRead
Slot B Option SW VersionRead
Option in Slot C0/E0Read
Slot C0/E0 Option SW VersionRead
Option in Slot C1/E1Read
Slot C1/E1 Option SW VersionRead
Defined ParametersRead
Modified ParametersRead
Parameter MetadataRead

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Show output frequency, motor current and power of each compressor drive on one ModbusCloud dashboard.
  • Send an email alert when the alarm word is not 0 so the service engineer knows a drive tripped.
  • Keep a year of suction pressure, P0 setpoint and pack capacity to spot short cycling or poor control.
  • Change the P0 setpoint or night setback remotely without a visit to the plant room.
  • Track running hours, number of starts and kWh per drive for maintenance planning and energy reports.

Installation

  1. Connect RS485 terminals 68 (+) and 69 (-) of the drive to RS485 A and B of the ModbusCloud Gateway and set switch S801 to on at the last device on the bus.

  2. On the drive set 8-30 Protocol to Modbus RTU, a unique address in 8-31 and the same baud rate and parity in 8-32 and 8-33 as in ModbusCloud.

  3. In ModbusCloud add a Modbus device with the same address and serial settings and import this template.

  4. Check that Frequency, Motor Voltage and DC Link Voltage show plausible values before you write any register.

Things to watch for

The drive does not answer on the bus. What should I check?

Check that 8-30 is set to Modbus RTU and not to FC protocol, and that address, baud rate and parity in 8-31 to 8-33 match ModbusCloud. Swap A and B if needed and set the termination switch only at both ends of the line.

Why do some parameters show strange values or change when I read again?

Many parameters are arrays, such as preset references or log entries. The drive returns the element set in the Array Index Pointer register. Write the index you want there first, then read the parameter.

Can I write parameters, and are the changes kept after a restart?

Yes, every setting is writable, but some only with the motor stopped. Coil 65, Parameter Write Control, decides where writes go: 0 keeps them in RAM only, 1 also stores them in EEPROM. Read a value first and change one parameter at a time, because a wrong ramp or limit can stop the compressor.

How do I start the drive and set its speed over Modbus?

Write the control word to Bus Control Word or to the control coils and the speed reference to Bus Reference, where 0x4000 equals 100 percent. The Data Valid bit must be 1, and 8-50 and related parameters decide whether the bus or the digital inputs have priority.

Want to see how it works?