Danfoss Danfoss AK-RC 305W-SD Modbus RTU template

Danfoss AK-RC 305W-SD

Cold room controller for walk-in coolers and freezers: temperatures, relays, defrost and alarms.

The Danfoss AK-RC 305W-SD is a temperature controller in a wall box that runs the compressor, defrost, evaporator fans and light of a walk-in cooler or freezer. This Modbus RTU template reads probe temperatures, relay states and alarms, and lets you write the setpoint, start a defrost and switch standby and light from ModbusCloud.

Protocol
Modbus RTU
Connection
RS485, 19200 baud
Registers
112, read and write
Brand
Danfoss
Key readings
Room temperature S1 · Evaporator temperature S2 · Effective setpoint · Cooling relay · Defrost state · Alarms
Available commands
Setpoint · Defrost start and stop · Standby · Light · Alarm limits
Compatible models
AK-RC 305W-SD (080Z5003)
Last updated

Registers (112)

112 read, 76 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Probe S1 Temperature°CRead
Probe S2 Temperature°CRead
Probe S3 Temperature°CRead
Effective Setpoint°CRead
Cooling Relay StateRead
Defrost Relay StateRead
Fan Relay StateRead
Defrost StateRead
Standby StateRead
Digital Input 1 StateRead
Digital Input 2 StateRead
Light StateRead
AUX1 Remote StateRead
AUX2 Remote StateRead
Setpoint Change StateRead
Continuous Cycle StateRead
Mute StateRead
Alarm Max S1Read
Alarm Min S1Read
Alarm Door OpenRead
Alarm ExternalRead
Alarm Severe ExternalRead
Probe S1 ErrorRead
Probe S2 ErrorRead
Probe S3 ErrorRead
Alarm Moisture S2Read
Alarm Moisture S3Read
Alarm HACCPRead
Alert Defrost TimeRead
Alert Pump Down PdRead
Alert Pump Down LPRead
Alert Power Fail HACCPRead
Alert HACCPRead
Alarm SD 16Read
Switch StandbyRead and write
Switch Setpoint ChangeRead and write
Switch Continuous CycleRead and write
Switch LightRead and write
Turn On MuteRead and write
Switch AUX1Read and write
Switch AUX2Read and write
Turn On DefrostRead and write
Turn Off DefrostRead and write
Setpoint°CRead and write
Regulation ModeRead and write
Probe 1 CalibrationKRead and write
Probe 1 DifferentialKRead and write
Setpoint Upper Limit°CRead and write
Setpoint Lower Limit°CRead and write
Delay TypeRead and write
Delay TimeRead and write
Cooling On Probe FailureRead and write
Cooling Time On On FailureRead and write
Cooling Time Off On FailureRead and write
Max Duration Continuous CycleRead and write
Setpoint Variation Continuous CycleKRead and write
Setpoint VariationKRead and write
Max Time On Pump DownRead and write
Max Time Pump DownRead and write
Probe DisplayedRead and write
Stop Fan With CoolingRead and write
Fan On DelayRead and write
Fan Stop DelayRead and write
S1 S3 BalanceRead and write
S3 CalibrationKRead and write
Defrost FrequencyRead and write
Defrost DurationRead and write
Defrost MessageRead and write
Defrost Message DurationRead and write
End Defrost Temperature°CRead and write
Defrost At Start UpRead and write
Start Up Defrost DelayRead and write
Defrost TypeRead and write
Time Between Defrosts ModeRead and write
Drip TimeRead and write
Fan Stop Temperature°CRead and write
Probe 2 DifferentialKRead and write
Stop Fan With CompressorRead and write
Fans During DefrostRead and write
Fan Delay After DefrostRead and write
Fan Stop Evaporator Temperature°CRead and write
Fan On CycleRead and write
Fan Off CycleRead and write
Alarm SetupRead and write
Max Alarm S1°CRead and write
Min Alarm S1°CRead and write
Alarm Start Up DelayRead and write
Alarm Delay After DefrostRead and write
Temperature Alarm DelayRead and write
External Alarm DelayRead and write
External Alarm Off DelayRead and write
Defrost WarningRead and write
Alarm Relay PolarityRead and write
Alarm DifferentialKRead and write
Open Door Alarm DelayRead and write
Start Up DelayRead and write
Light TimeRead and write
Password FunctionRead and write
PasswordRead and write
Acoustic AlarmRead and write
Work UnitsRead and write
Connected ProbesRead and write
Digital Input 1 SetupRead and write
Digital Input 1 PolarityRead and write
Digital Input 2 SetupRead and write
Digital Input 2 PolarityRead and write
AUX1 SetupRead and write
AUX2 SetupRead and write
HACCP Temperature°CRead and write
HACCP DelayRead and write
Start WizardRead
Pump DownRead

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Use cases

  • Show room temperature, evaporator temperature and relay states of every cold room on one dashboard.
  • Get an email when the high or low temperature alarm, door alarm or a probe error turns on.
  • Keep a year of cold room temperature history as a record for food safety checks.
  • Start a manual defrost from ModbusCloud when the evaporator ices up.
  • Raise or lower the setpoint remotely when the room changes from cooler to freezer use.

Installation

  1. Wire the RS485 terminals of the AK-RC 305W-SD to the RS485 port of the ModbusCloud Gateway, with a 120 ohm resistor at both ends of the bus.

  2. Check the address and serial settings of the controller; this template assumes 19200 baud, 8E1 and address 1.

  3. In ModbusCloud, add a Modbus device (RTU) with those settings and import this template.

  4. Check that probe S1 shows the room temperature and that the cooling relay state follows the display.

  5. Add alarm rules on the alarm registers you want to follow, such as max and min alarm S1 and door open.

Things to watch for

The controller does not answer on the bus. What should I check?

The serial settings are not in the Modbus list, so check them on the controller first. Try 19200 baud, even parity, 1 stop bit and address 1. Swap A and B if nothing answers, and make sure the bus has a 120 ohm termination at both ends.

Why does a probe show -327.67?

That is the raw value -32767, which the controller sends when a probe has no valid reading. Check the probe and its wiring; the matching probe error register will be on as well.

Why are temperatures a hundred times too high?

Temperatures are sent in hundredths of a degree, so 450 means 4.50. The template applies that scale. If the controller is set to Fahrenheit, the values are in °F.

How do I start a defrost or change the setpoint safely?

Write 1 to Turn On Defrost to start one and to Turn Off Defrost to end it; Defrost State shows the result. Write the setpoint in degrees within the upper and lower setpoint limits. Agree remote changes with whoever is responsible for the cold room.