Danfoss AK-CC 350
Controls temperature, defrost and fans in refrigerated display cabinets and cold rooms.
The Danfoss AK-CC 350 is a case and cold room controller that regulates temperature, defrost and fans in refrigerated display cabinets and cold rooms. This Modbus RTU template reads all temperatures, the controller state and every alarm, and lets you change the setpoint, alarm limits and defrost settings from ModbusCloud.
- Protocol
- Modbus RTU
- Connection
- RS485, 38400 baud
- Registers
- 118, read and write
- Brand
- Danfoss
- Key readings
- Thermostat air temperature · S3 and S4 air temperature · S5 evaporator temperature · HACCP temperature · Controller state · Alarm flags
- Available commands
- Temperature setpoint · Main switch · Defrost start · Alarm limits · Defrost schedule
- Compatible models
- AK-CC 350 (084B4165)
- Last updated
Registers (118)
118 read, 85 write
| Name | Unit | Access | Address (Hidden until you enter your email) | Function (hidden) | Type (hidden) |
|---|---|---|---|---|---|
| Thermostat Air Temperature | °C | Read | |||
| S4 Air Temperature | °C | Read | |||
| S3 Air Temperature | °C | Read | |||
| S5 Temperature | °C | Read | |||
| Display Air Temperature | °C | Read | |||
| Alarm Air Temperature | °C | Read | |||
| Regulation Reference | °C | Read | |||
| HACCP Temperature | °C | Read | |||
| HACCP Peak Temperature | °C | Read | |||
| Controller State | Read | ||||
| Defrost State | Read | ||||
| DI1 Status | Read | ||||
| DI2 Status | Read | ||||
| Night Condition | Read | ||||
| Controller Error | Read | ||||
| Controller Error Alarm | Read | ||||
| Clock Error Alarm | Read | ||||
| S3 Sensor Error | Read | ||||
| S4 Sensor Error | Read | ||||
| S5 Sensor Error | Read | ||||
| High Temperature Alarm | Read | ||||
| Low Temperature Alarm | Read | ||||
| HACCP Alarm | Read | ||||
| Door Alarm | Read | ||||
| DI1 Alarm | Read | ||||
| DI2 Alarm | Read | ||||
| Max Defrost Time Alarm | Read | ||||
| Max Hold Time Alarm | Read | ||||
| Case Cleaning Alarm | Read | ||||
| Standby Mode Alarm | Read | ||||
| Main Switch | Read and write | ||||
| Temperature Setpoint | °C | Read and write | |||
| Defrost Start | Read and write | ||||
| Reset Alarm | Read and write | ||||
| Forced Cooling | Read and write | ||||
| Night Setback | Read and write | ||||
| Thermostat Differential | K | Read and write | |||
| Max Setpoint Limit | °C | Read and write | |||
| Min Setpoint Limit | °C | Read and write | |||
| Display S4 Weighting | % | Read and write | |||
| Display Temperature Adjustment | K | Read and write | |||
| Temperature Unit | Read and write | ||||
| S4 Sensor Correction | K | Read and write | |||
| S3 Sensor Correction | K | Read and write | |||
| Night Setback Offset | K | Read and write | |||
| Thermostat S4 Weighting | % | Read and write | |||
| Reference Offset Active | Read and write | ||||
| Reference Offset | K | Read and write | |||
| Compressor Min On Time | min | Read and write | |||
| Compressor Min Off Time | min | Read and write | |||
| Compressor Relay NC Function | Read and write | ||||
| External Relays | Read and write | ||||
| Defrost Method | Read and write | ||||
| Defrost Stop Temperature | °C | Read and write | |||
| Defrost Interval | h | Read and write | |||
| Max Defrost Duration | min | Read and write | |||
| Defrost Start Delay At Power Up | min | Read and write | |||
| Drip Off Time | min | Read and write | |||
| Fan Start Delay After Defrost | min | Read and write | |||
| Fan Start Temperature | °C | Read and write | |||
| Fan During Defrost | Read and write | ||||
| Defrost Stop Sensor | Read and write | ||||
| Pump Down Delay | min | Read and write | |||
| Max Refrigeration Time Between Defrosts | h | Read and write | |||
| Defrost On Demand S5 Variation | K | Read and write | |||
| Hold After Defrost | Read and write | ||||
| Max Hold Time After Coordinated Defrost | min | Read and write | |||
| Defrost 1 Start Hour | h | Read and write | |||
| Defrost 1 Start Minute | min | Read and write | |||
| Defrost 2 Start Hour | h | Read and write | |||
| Defrost 2 Start Minute | min | Read and write | |||
| Defrost 3 Start Hour | h | Read and write | |||
| Defrost 3 Start Minute | min | Read and write | |||
| Defrost 4 Start Hour | h | Read and write | |||
| Defrost 4 Start Minute | min | Read and write | |||
| Defrost 5 Start Hour | h | Read and write | |||
| Defrost 5 Start Minute | min | Read and write | |||
| Defrost 6 Start Hour | h | Read and write | |||
| Defrost 6 Start Minute | min | Read and write | |||
| Fan Stop At Compressor Cutout | Read and write | ||||
| Fan Stop Delay | min | Read and write | |||
| Fan Stop Temperature | °C | Read and write | |||
| Temperature Alarm Delay | min | Read and write | |||
| Door Alarm Delay | min | Read and write | |||
| Alarm Delay After Defrost | min | Read and write | |||
| High Alarm Limit | °C | Read and write | |||
| Low Alarm Limit | °C | Read and write | |||
| DI1 Alarm Delay | min | Read and write | |||
| DI2 Alarm Delay | min | Read and write | |||
| Alarm S4 Weighting | % | Read and write | |||
| HACCP Sensor Selection | Read and write | ||||
| HACCP Alarm Limit | °C | Read and write | |||
| HACCP Alarm Delay | min | Read and write | |||
| HACCP S4 Weighting | % | Read and write | |||
| Output Delay At Start Up | s | Read and write | |||
| DI1 Configuration | Read and write | ||||
| Sensor Type | Read and write | ||||
| DI2 Configuration | Read and write | ||||
| Case Cleaning | Read and write | ||||
| Compressor Relay | Read and write | ||||
| Defrost Relay | Read and write | ||||
| Fan Relay | Read and write | ||||
| Alarm Relay | Read and write | ||||
| Light Configuration | Read and write | ||||
| Light Remote Switch | Read and write | ||||
| Light Relay | Read and write | ||||
| Rail Heat On Time Day | % | Read and write | |||
| Rail Heat On Time Night | % | Read and write | |||
| Rail Heat Period | min | Read and write | |||
| Rail Heat Relay | Read and write | ||||
| Drain Delay | min | Read and write | |||
| Suction Line Valve Relay | Read and write | ||||
| Compressor 2 Cut In Delay | s | Read and write | |||
| Compressor 2 Relay | Read and write | ||||
| Heat Function Start Offset | K | Read and write | |||
| Application Mode | Read | ||||
| Module Software Version | Read | ||||
| Transceiver Type | Read |
Loading registers…
Send your device list
If a device is not in the library yet, we build the template for free as soon as we have the register data.
Use cases
- Show the thermostat air temperature of every cabinet in one dashboard and keep a year of history as evidence for food safety checks.
- Send an email when the high or low temperature alarm flag goes to 1, or when a sensor error appears.
- Alert when the HACCP temperature passes its limit, separately from the normal temperature alarm.
- Check from the history whether defrosts start on schedule and how long the cabinet stays in each controller state.
- Adjust the setpoint or alarm limits of a cold room remotely after a change in the stored product.
Installation
Connect the Disp./MODBUS terminals A+ and B- of the controller to the RS485 port of the ModbusCloud Gateway, with a 120 ohm termination at the end of the bus.
Set a unique network address in parameter o03 (1 to 240) on each controller.
In ModbusCloud, add a Modbus device with that address, 38400 baud, 8 data bits, even parity and 1 stop bit, and import this template.
Check that the thermostat air temperature and the controller state show plausible values.
If nothing answers, try 19200 or 9600 baud and swap A+ and B- once.
Things to watch for
The controller does not answer at all. What should I check?
Check that o03 holds an address other than 0, that the wires go to the Disp./MODBUS terminals and not the LON RS485 terminals, and that A+ and B- are not swapped. Danfoss does not publish the serial settings for this controller; start at 38400 baud 8E1 and try 19200 and 9600 if it stays silent.
Why do I read 1200 on the S3 or S5 temperature?
Temperatures come in tenths, so the template shows 120.0. A fixed high value like this usually means the sensor is not connected or not used in the selected application. The matching sensor error flag tells you whether the controller sees a fault.
Writing a setting has no effect. Why?
Some settings, such as the defrost method and the input configuration, can only change while the main switch stops regulation (0). Relay registers only switch in manual service (main switch -1). Set the main switch back to 1 afterwards, otherwise the cabinet stops cooling.
Some registers return errors or zero. Is the template wrong?
The controller has ten applications and not every function exists in each one: light, rail heat, a second compressor and the suction line valve only appear in some. Application Mode shows which one is active, and registers for other applications can stay empty.
Want to see how it works?