Siemens Modbus templates
All 19 available Siemens templates for ModbusCloud.
Monitor Siemens RDF thermostats and Sentron PAC energy meters via Modbus RTU and Modbus TCP.
- Templates
- 19
- Connection
- Modbus RTU and TCP
- Registers
- 1 to 1079 per template
- Compatible models
- Sentron PAC3100 · Sentron PAC 2200 · RDF302 · RDF660MB · SENTRON PAC3200 · SENTRON PAC3220 · SENTRON PAC3120 · 7KM3220-0BA01-1DA0 · 7KM3220-1BA01-1EA0 · 7KM3120-0BA01-1DA0 · 7KM3120-1BA01-1EA0 · SENTRON PAC4200 · SINAMICS G120 (Control Unit with RS485 interface) · SINAMICS G120C (RS485 version) · SINAMICS G120P · SINAMICS G120X · SINAMICS V20 (all frame sizes, 1AC 230 V and 3AC 400 V) · SITRANS FM MAG 6000 · SITRANS FM MAG 6000 19" · SITRANS FM MAG 6000 I · SITRANS FM MAG 6000 SV
- Last updated
Siemens templates
11 via Modbus RTU, 8 via Modbus TCP
Siemens Junelight Smart Battery (battery)Modbus TCP2 read, 0 write
Siemens Sentron PAC3100 Power meter 3 phaseReads 3-phase power metering data from a Siemens Sentron PAC3100.Modbus RTU70 read, 0 write
Siemens Sentron PAC 2200Monitors three-phase energy metering via Modbus TCP on Siemens Sentron PAC 2200.Modbus TCP18 read, 0 write
Siemens RDF302Controls a Siemens room thermostat via Modbus RTUModbus RTU2 read, 1 write
Siemens RDF660MB Controls a Siemens room thermostat via Modbus RTUModbus RTU2 read, 1 write
Siemens 7KT1665 (charge)Modbus RTU5 read, 0 write
Siemens 7KT1665 (grid)Modbus RTU5 read, 0 write
Siemens Junelight Smart Battery (grid)Modbus TCP1 read, 0 write
Siemens Junelight Smart Battery (pv)Modbus TCP1 read, 0 write
Siemens PAC1600Modbus RTU36 read, 0 write
Siemens SENTRON PAC3200Power monitoring device for voltage, current, power, energy per tariff and power quality.Modbus RTU256 read, 104 write
Siemens SENTRON PAC3220Power monitor for distribution boards: voltage, current, power, energy per tariff and power quality.Modbus TCP908 read, 236 write
Siemens SENTRON PAC4200Power monitoring device for switchboards: voltage, current, power, harmonics and energy per tariff.Modbus TCP1065 read, 172 write
Siemens SICAMT7KG966Modbus TCP17 read, 0 write
Siemens SiemensModbus TCP17 read, 0 write
Siemens SINAMICS G120Frequency converter: speed, current, power, faults and remote start, stop and setpoint.Modbus RTU192 read, 147 write
Siemens SINAMICS G120XPump and fan converter: speed, current, power, energy and faults, with start, stop and setpoint over RS485.Modbus RTU189 read, 147 write
Siemens SINAMICS V20Compact frequency converter: frequency, current, power, faults and remote start, stop and setpoint.Modbus RTU262 read, 186 write
Siemens SITRANS FM MAG 6000Electromagnetic flow transmitter for water and other conductive liquids, with flow, totalizers and error status.Modbus RTU291 read, 75 write
The scan recognises these devices
Connect them to RS485 or the network and start a scan in the portal.
Gateway
Portal
Incl. 4G data up to 30 MB per month
Excl. VAT. White label customer portal included. All prices
Order your first gateway100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

Siemens Smart Infrastructure covers building automation and electrical energy measurement. The 4 Siemens Modbus templates in our library cover the RDF302 and RDF660MB room thermostats (HVAC setpoint control) and the Sentron PAC 2200 and PAC3100 three-phase power meters (electrical distribution monitoring). Together they span both sides of building management, climate control and energy visibility, on a single Modbus dashboard.
With ModbusCloud and these Siemens Modbus RTU/TCP templates you read room temperature and setpoints from RDF thermostats and write room setpoints for remote climate adjustment. For Sentron PAC meters you read per-phase and total active, reactive and apparent power, voltage, current, frequency, power factor, and min/max statistics. The PAC3100 additionally exposes historic min/max data for commissioning baselines and power-quality analysis.
All 4 Siemens templates are free to browse. Import one into your ModbusCloud portal to operate HVAC setpoints and supervise three-phase electrical distribution from the same dashboard.
What you can read out
- Room temperature and setpoint (RDF)
- Per-phase voltage, current and power (Sentron)
- Reactive and apparent power
- Frequency and power factor
- Min/max statistics (PAC3100)
Typical installations
- Office HVAC with centrally managed room thermostats
- Commercial three-phase distribution monitoring
- Integrated BMS with combined climate and energy visibility