Siemens Modbus templates

All 19 available Siemens templates for ModbusCloud.

Monitor Siemens RDF thermostats and Sentron PAC energy meters via Modbus RTU and Modbus TCP.

Templates
19
Connection
Modbus RTU and TCP
Registers
1 to 1079 per template
Compatible models
Sentron PAC3100 · Sentron PAC 2200 · RDF302 · RDF660MB · SENTRON PAC3200 · SENTRON PAC3220 · SENTRON PAC3120 · 7KM3220-0BA01-1DA0 · 7KM3220-1BA01-1EA0 · 7KM3120-0BA01-1DA0 · 7KM3120-1BA01-1EA0 · SENTRON PAC4200 · SINAMICS G120 (Control Unit with RS485 interface) · SINAMICS G120C (RS485 version) · SINAMICS G120P · SINAMICS G120X · SINAMICS V20 (all frame sizes, 1AC 230 V and 3AC 400 V) · SITRANS FM MAG 6000 · SITRANS FM MAG 6000 19" · SITRANS FM MAG 6000 I · SITRANS FM MAG 6000 SV
Last updated

Siemens templates

11 via Modbus RTU, 8 via Modbus TCP

The scan recognises these devices

Connect them to RS485 or the network and start a scan in the portal.

Gateway

€295one-off

Portal

€149per year

Incl. 4G data up to 30 MB per month

or
€495one-off

Excl. VAT. White label customer portal included. All prices

Order your first gateway

100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

The ModbusCloud Gateway with the RS485 terminal and the antenna connectors

Siemens Smart Infrastructure covers building automation and electrical energy measurement. The 4 Siemens Modbus templates in our library cover the RDF302 and RDF660MB room thermostats (HVAC setpoint control) and the Sentron PAC 2200 and PAC3100 three-phase power meters (electrical distribution monitoring). Together they span both sides of building management, climate control and energy visibility, on a single Modbus dashboard.

With ModbusCloud and these Siemens Modbus RTU/TCP templates you read room temperature and setpoints from RDF thermostats and write room setpoints for remote climate adjustment. For Sentron PAC meters you read per-phase and total active, reactive and apparent power, voltage, current, frequency, power factor, and min/max statistics. The PAC3100 additionally exposes historic min/max data for commissioning baselines and power-quality analysis.

All 4 Siemens templates are free to browse. Import one into your ModbusCloud portal to operate HVAC setpoints and supervise three-phase electrical distribution from the same dashboard.

What you can read out

  • Room temperature and setpoint (RDF)
  • Per-phase voltage, current and power (Sentron)
  • Reactive and apparent power
  • Frequency and power factor
  • Min/max statistics (PAC3100)

Typical installations

  • Office HVAC with centrally managed room thermostats
  • Commercial three-phase distribution monitoring
  • Integrated BMS with combined climate and energy visibility

Want to see how it works?