SOLARFOCUS SOLARFOCUS Distribution Modbus TCP template

SOLARFOCUS Distribution

Controls SOLARFOCUS heat distribution units via Modbus TCP

This template connects SOLARFOCUS heat distribution units equipped with the ecoManager-touch controller via Modbus TCP. It reads flow temperatures, mixing valve positions, circulation pump states, and buffer/hot water storage temperatures. It also allows control of target temperatures, operation modes, and cooling release for two heating circuits.

Protocol
Modbus TCP
Connection
Ethernet, Modbus TCP
Registers
31, read and write
Key readings
Flow Temperature HC1/HC2 · Mixing Valve Position HC1/HC2 · Circulation Pump State HC1/HC2 · Buffer Temperature Top/Bottom · Hot Water Storage Temperature · Operation Mode HC1/HC2
Available commands
Target Flow Temperature HC1/HC2 · Hot Water Target Temperature · Operation Mode HC1/HC2 · Release Cooling HC1/HC2
Last updated

Registers (31)

18 read, 13 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
1100 - Actual Flowtemperature HC1°CRead
1103 - State Safety Temperature Thermostat HC1Read
1105 - State Circulationpump HC1Read
1106 - State Mixing Valve Position HC1%Read
1107 - State Operation mode HC1Read
1150 - Actual Flowtemperature HC2°CRead
1153 - State Safety Temperature Thermostat HC2Read
1155 - State Circulationpump HC2Read
1156 - State Mixing Valve Position HC2%Read
1157 - State Operation mode HC2Read
1900 - Actual Heating/Cooling Buffer Temperature Top°CRead
1901 - Actual Heating/Cooling Buffer Temperature Bottom°CRead
1903 - State Heating/Cooling Buffer Circulation PumpRead
1904 - State Heating/Cooling Buffer Operation stateRead
1905 - State Heating/Cooling Buffer Operation modeRead
500 - Actual Hot Water Storage Temperature°CRead
501 - State Hot Water Storage Operation StateRead
502 - State Hot Water Storage Operation modeRead
32600 - Target Flowtemperature HC1°CWrite
32602 - Release Cooling HC1Write
32603 - Operation Mode HC1Write
32003 - Hot Water CirculationpumpWrite
32650 - Target Flowtemperature HC2Write
32652 - Release Cooling HC2Write
32653 - Operating mode HC2Write
32000 - Hot Water Targettemperature°CWrite
32002 - Hot Water Operation modeWrite
32608 - Operation Mode HC1Write
32658 - Operation Mode HC2Write
32606 - Actual Roomtemperature HC1°CWrite
32656 - Actual Roomtemperature HC2°CWrite

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Monitor flow temperatures and mixing valve positions of two heating circuits on a live cloud dashboard.
  • Set target flow temperatures and operation modes remotely to adjust comfort levels without a site visit.
  • Create an alert when buffer storage top temperature drops below a defined threshold for early fault detection.
  • Log hot water storage temperature over time to verify domestic hot water performance and setpoint compliance.
  • Combine this template with SOLARFOCUS heat pump or pellet boiler templates to supervise the full heating system.
  • Release or disable cooling mode for individual heating circuits remotely during seasonal transitions.

Installation

  1. Connect the SOLARFOCUS ecoManager-touch controller to your local network via Ethernet and note its IP address.

  2. Wire the ModbusCloud Gateway to the same local network, ensuring it can reach the controller IP.

  3. In the ecoManager-touch settings, verify that Modbus TCP communication is enabled and confirm the default TCP port (typically 502).

  4. Import the SOLARFOCUS Distribution template in the ModbusCloud platform and assign the controller IP address and port.

  5. If external room temperature sensors are used, configure registers 32606 and 32656 as writable inputs in the template settings.

  6. When combining with other SOLARFOCUS templates (heat pump, pellet, biomass), import those additional templates for the same gateway and verify there are no register address conflicts.

Things to watch for

Why do I need multiple SOLARFOCUS templates instead of just one?

The Distribution template covers heating circuits, buffer storage, and hot water storage only. Heat generation equipment such as heat pumps, pellet boilers, or biomass boilers each have their own register sets and require a separate dedicated template.

What are the writable room temperature registers (32606, 32656) used for?

These registers allow you to send an external room temperature value to the ecoManager-touch controller. If you have room sensors connected through the gateway rather than directly to the SOLARFOCUS system, write the measured value to these registers so the controller can use it for regulation.

The gateway connects but no data appears on the dashboard. What should I check?

Confirm that Modbus TCP is enabled on the ecoManager-touch and that the IP address and port (usually 502) match the template configuration. Also verify that no firewall or VLAN boundary is blocking traffic between the gateway and the controller.

Can I control cooling release remotely through this template?

Yes. The template includes Release Cooling registers for HC1 and HC2. Writing the appropriate value activates or deactivates cooling mode for each circuit independently.