SOLARFOCUS Modbus templates
All 5 available SOLARFOCUS templates for ModbusCloud.
Monitor SOLARFOCUS pellet boilers, heat pumps, solar and ventilation systems over Modbus TCP.
- Templates
- 5
- Connection
- Modbus TCP
- Registers
- 10 to 31 per template
- Compatible models
- Vampair K · Vampair Pro · Pellet Elegance · Octoplus · Ecotop · Pellet Top · therminator II touch
- Last updated
SOLARFOCUS templates
5 via Modbus TCP
Solarfocus Heating & CoolingControls and monitors Solarfocus heating and cooling systems via Modbus TCP.Modbus TCP21 read, 1 write
SOLARFOCUS Pelletelegance,Octoplus, Ecotop, PellettopMonitors and controls SOLARFOCUS biomass pellet boilers via Modbus TCP.Modbus TCP10 read, 1 write
SOLARFOCUS therminator II touchMonitors and controls a SOLARFOCUS pellet boiler via Modbus TCP.Modbus TCP9 read, 1 write
SOLARFOCUS SolarReads SOLARFOCUS solar collector and tank values via Modbus TCP.Modbus TCP12 read, 0 write
SOLARFOCUS DistributionControls SOLARFOCUS heat distribution units via Modbus TCPModbus TCP18 read, 13 write
The scan recognises these devices
Connect them to RS485 or the network and start a scan in the portal.
Gateway
Portal
Incl. 4G data up to 30 MB per month
Excl. VAT. White label customer portal included. All prices
Order your first gateway100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

SOLARFOCUS is an Austrian manufacturer of renewable heating systems, pellet boilers (Pelletelegance, Octoplus, Ecotop, Pellettop), heat pumps, thermal solar, and therminator II wood boilers, all managed by the ecoManager-touch controller. The 5 SOLARFOCUS Modbus TCP templates in our library cover SOLARFOCUS Distribution for heating/cooling circuits, the Heating & Cooling heat pump template, pellet boilers, Solar thermal systems, and the therminator II touch wood boiler.
With ModbusCloud and these SOLARFOCUS Modbus TCP templates you monitor boiler temperature, flow rates, buffer and storage temperatures, compressor speed, thermal and electrical energy totals, and operating states. The Distribution template handles two heating circuits with flow temperatures, mixing valves, circulation pumps and operation modes. Pellet boiler templates expose ash-box fill level, cleaning level and outside temperature; an external outside-temperature value can be written to drive weather-compensated control.
All 5 SOLARFOCUS templates are free to browse. Import one into your ModbusCloud portal to supervise SOLARFOCUS renewable heating installations across multiple homes or commercial sites from one dashboard.
What you can read out
- Boiler, buffer and storage temperatures
- Thermal and electrical energy totals
- Compressor speed and heat pump flow rate
- Ash-box fill and cleaning level (pellet)
- Solar collector temperatures and yield
Typical installations
- Residential pellet-boiler installations with buffer tanks
- Commercial SOLARFOCUS heat-pump installations with EVU control
- Multi-site supervision for installer service contracts