Controls Alnor HRU-P heat recovery ventilation units via Modbus RTU.
Overzicht
Belangrijke uitlezingen
- Supply/Extract/Inlet/Exhaust temperatures

Alnor Systemy Wentylacji Sp. z o. o.
Controls Alnor HRU-P heat recovery ventilation units via Modbus RTU.
49 lezen / 23 schrijven
| Naam | Adres | Functie | Type | Eenheid | Toegang |
|---|---|---|---|---|---|
Error Status (R) Device failure signaling | 3 | FC03 | uint16 | R | |
Work Mode (RW) Read current work mode of the unit | 4 | FC03 | uint16 | R/W | |
Exhaust temperature sensor (R) Exhaust temperature sensor | 9 | FC03 | int16 | ºC | R |
Extract temperature sensor (R) Extract temperature sensor | 7 | FC03 | uint16 | ºC | R |
Inlet temperature sensor (R) Inlet temperature sensor | 8 | FC03 | uint16 | ºC | R |
Supply temperature sensor (R) Supply temperature sensor | 6 | FC03 | uint16 | ºC | R |
Pre-heater thermostat (R) 0 - open contact 1 - contact closed | 15 | FC03 | uint16 | R | |
Afterheater thermostat (R) 0 - open contact 1 - contact closed | 16 | FC03 | uint16 | R | |
Bypass status (R) 0 - ON, 1 - OFF | 17 | FC03 | uint16 | R | |
SAP signal (R) 0 - SAP 1 -NO SAP | 18 | FC03 | uint16 | R | |
Pre-heater status (R) 0 - Inactive 1 - Active | 22 | FC03 | uint16 | R | |
Afterhater status (R) 0 - Inactive 1 - Active | 23 | FC03 | uint16 | R | |
Bypass position (R) | 27 | FC03 | uint16 | % | R |
Time Mode OUT (RW) 0 - Inactive 1 - Active | 33 | FC03 | uint16 | R/W | |
Time Mode PARTY (RW) 0 - Inactive 1 - Active | 34 | FC03 | uint16 | R/W | |
Fireplace Mode (RW) 0 - Inactive 1 - Active | 35 | FC03 | uint16 | R/W | |
Supply fan speed (R) Supply fan speed | 43 | FC03 | uint16 | % | R |
Exhaust fan speed (R) Exhaust fan speed | 44 | FC03 | uint16 | % | R |
Supply fan speed - Speed 1 (RW) | 48 | FC03 | uint16 | % | R/W |
Supply fan speed - Speed 2 (RW) | 49 | FC03 | uint16 | % | R/W |
Supply fan speed - Speed 3 (RW) | 50 | FC03 | uint16 | % | R/W |
Exhaust fan speed - Speed 2 (RW) | 55 | FC03 | uint16 | % | R/W |
Exhaust fan speed - Speed 3 (RW) | 56 | FC03 | uint16 | % | R/W |
Exhaust fan speed - Speed 1 (RW) | 54 | FC03 | uint16 | % | R/W |
Flow setpoint supply (R) | 98 | FC03 | uint16 | m3/h | R |
Supply fan flow - Speed 2 (RW) | 109 | FC03 | uint16 | m3/h | R/W |
Flow setpoint exhaust (R) W zależnosci od modelu rekuperacji ... | 99 | FC03 | uint16 | m3/h | R |
Flow reading supply (R) Flow reading supply | 94 | FC03 | uint16 | m3/h | R |
Flow reading exhaust (R) Flow reading exhaust | 95 | FC03 | uint16 | m3/h | R |
Supply fan flow - Speed 1 (RW) | 108 | FC03 | uint16 | m3/h | R/W |
Supply fan flow - Speed 3 (RW) | 110 | FC03 | uint16 | m3/h | R/W |
Exhaust fan flow - Speed 1 (RW) | 112 | FC03 | uint16 | m3/h | R/W |
Exhaust fan flow - Speed 2 (RW) | 113 | FC03 | uint16 | m3/h | R/W |
Exhaust fan flow - Speed 3 (RW) | 114 | FC03 | uint16 | m3/h | R/W |
GHE status (R) 0 - Inactive 1 - Active | 26 | FC03 | uint16 | R | |
GHE mode (RW) 0 - closed, 1 - open, 2 - auto | 69 | FC03 | uint16 | R/W | |
GHE winter temperature (RW) | 70 | FC03 | uint16 | ºC | R/W |
GHE summer temperature (RW) | 71 | FC03 | uint16 | ºC | R/W |
Filter alarm (R) 0 - Inactive 1 - Active | 202 | FC03 | uint16 | R | |
Turn ON/OFF (RW) 0 - OFF, 1 - ON | 1 | FC03 | uint16 | R/W | |
Supply filter days left (R) | 84 | FC03 | uint16 | days | R |
Exhaust filter days left (R) | 85 | FC03 | uint16 | days | R |
Supply air filter - depletion (R) Supply air filter - depletion | 86 | FC03 | uint16 | % | R |
Exhaust air filter - depletion (R) Exhaust air filter - depletion | 87 | FC03 | uint16 | % | R |
Reset filter counting (RW) 2 - Only supply filter, 3 - Only exhaust filter, 7 - Both filters | 88 | FC03 | uint16 | R/W | |
Bypass control (RW) 1 - Closed, 2 - Open, 3 - AUTO | 89 | FC03 | uint16 | R/W | |
Airing time mode (RW) 0 - Inactive 1 - Active | 32 | FC03 | uint16 | R/W | |
Humidity indoor (R) | 41 | FC03 | uint16 | % | R |
CO2 indoor (R) | 42 | FC03 | uint16 | ppm | R |
Importeer deze template met een klik in je eigen portaal of neem contact op voor begeleiding bij de installatie.
AMPERFIED GmbH
Controls and monitors Heidelberg Wallbox Energy Control EV charger via Modbus RTU.

Wattsonic
Monitors Schmachtl Wattsonic hybrid inverter via Modbus RTU

connecdoor
Controls and monitors smart door access points via RS485

E+E Elektronik
Measures heated humidity and temperature for meteorology applications

E+E Elektronik
Measures differential air pressure for HVAC and filter monitoring applications.

E+E Elektronik
Measures CO2, temperature, humidity and dew point for room climate control