ABB Modbus-templates
Alle 14 beschikbare ABB-templates voor ModbusCloud.
- Templates
- 14
- Verbinding
- Modbus RTU
- Registers
- 11 tot 1491 per template
- Ondersteunde modellen
- ABB B23 · ABB Terra AC · ACH580-01 · ACH580-04 · ACH580-07 · ACH580-31 · ACH580-34 · ACQ580 · ABB ACQ580-01 · ABB ACQ580-31 · ABB ACQ580-34 · ACS310-01E · ACS310-01U · ACS310-03E · ACS310-03U · ACS355-01E · ACS355-03E · ACS355-01U · ACS355-03U · ACS480-04 · ACS580-01 · ACS580-04 · ACS580-07 · ACS880 single drives with primary control program 3.1x or later (embedded fieldbus on XD2D) · ACS880 single drives with primary control program 3.1x or later, with FIO-01, FIO-11, FDIO-01, FAIO-01, FEN-xx or FDCO/RDCO options · M4M 30 Modbus · M4M 30 I/O · M4M 30 Rogowski · M4M 30 Ethernet · PSTX30 to PSTX1250 softstarters with built-in Modbus RTU · UMC100.3 with MRP31.0 · WaterMaster FEX100-MB · WaterMaster FEV11 · WaterMaster FEV12 · WaterMaster FEW11 · WaterMaster FEW12 · WaterMaster FEW31 · WaterMaster FEW32 · WaterMaster FEF12 · WaterMaster FER111 · WaterMaster FER121 · WaterMaster FET10 · WaterMaster FET12
- Laatst bijgewerkt
ABB-templates
14 via Modbus RTU
Energy meter ABB B23Reads energy values from a 3-phase ABB B23 energy meter via Modbus RTU.Modbus RTU13 lezen, 0 schrijven
ABB Terra ACMonitors and controls ABB Terra AC Wallbox charging via Modbus RTUModbus RTU9 lezen, 2 schrijven
ABB ACH580HVAC frequency converter for fans and pumps with speed, power, energy, faults and all parameters over Modbus RTU.Modbus RTU1491 lezen, 1202 schrijven
ABB ACQ580Pump drive for water and wastewater with speed, power, energy, faults and all pump control parameters.Modbus RTU1271 lezen, 1036 schrijven
ABB ACS310Pump and fan frequency converter with built-in PID and multi-pump control, over embedded Modbus RTU.Modbus RTU639 lezen, 515 schrijven
ABB ACS355Compact frequency converter: speed, current, power and faults, with control word and all parameters.Modbus RTU623 lezen, 524 schrijven
ABB ACS480Compact frequency converter: motor readings, energy, faults, start and stop, speed reference and settings.Modbus RTU1181 lezen, 962 schrijven
ABB ACS580General purpose frequency converter: motor readings, energy, faults, start and stop, speed reference and settings.Modbus RTU978 lezen, 789 schrijven
ABB ACS880Industrial frequency converter: speed, current, power, faults, control word and drive parameters over Modbus RTU.Modbus RTU1386 lezen, 1053 schrijven
ABB ACS880 Option ModulesOption module parameters of the ABB ACS880: extra I/O, master/follower link and encoder interfaces.Modbus RTU436 lezen, 374 schrijven
ABB M4M 30Network analyzer for switchboards: voltage, current, power, energy and harmonics per phase.Modbus RTU876 lezen, 102 schrijven
ABB PSTXSoftstarter for three-phase motors: start and stop, currents, temperatures and protection events.Modbus RTU28 lezen, 32 schrijven
ABB UMC100.3Motor controller for MCCs: motor current, thermal load, trips and run commands.Modbus RTU26 lezen, 20 schrijven
ABB WaterMasterElectromagnetic water flowmeter with flow, forward and reverse totals, alarms and diagnostics.Modbus RTU407 lezen, 89 schrijven
De scan herkent deze apparaten
Sluit ze aan op RS485 of het netwerk en start een scan in het portaal.
Gateway
€295eenmalig
Portaal
€149per jaar
Incl. 4G-data tot 30 MB per maand
€495eenmalig
Excl. btw. White label klantportaal inbegrepen. Alle prijzen
Bestel jouw eerste gateway100 dagen niet-goed-geld-teruggarantieMaakt de gateway geen verbinding met een Modbus-apparaat uit onze templatebibliotheek, dan krijg je jouw geld terug.

Zelf zien hoe het werkt?