iQntrol DOS-MODBUS dosing system
Peraqua
Monitors and controls pH/Redox dosing for private pool water disinfection.
Überblick
Wichtige Messwerte
- pH value
- Redox (mV)
- Temperature
- Chemical canister levels
- Flow and leak alarms
- Fuse fault status

Peraqua
Monitors and controls pH/Redox dosing for private pool water disinfection.
43 lesen / 12 schreiben
| Name | Adresse | Funktion | Typ | Einheit | Zugriff |
|---|---|---|---|---|---|
16 - Temperature | 16 | FC04 | float32 | °C | R |
38- pH - p-range | 38 | FC03 | float32 | R/W | |
B02 - disinfection empty | 2 | FC02 | uint16 | R | |
B03 - pH regulation empty | 3 | FC02 | uint16 | R | |
B32 - pH min Alarm | 32 | FC02 | uint16 | R | |
B33 - pH max Alarm | 33 | FC02 | uint16 | R | |
B13 - no flow | 13 | FC02 | uint16 | R | |
B16 - pH regulation leak | 16 | FC02 | uint16 | R/W | |
B17 - disinfection leak | 17 | FC02 | uint16 | R | |
B36 - mV min Alarm | 36 | FC02 | uint16 | R | |
B37 - mV max. Alarm | 37 | FC02 | uint16 | R | |
B41 - IO-Board F1 fuse fault (24V Desinfektion) | 41 | FC02 | uint16 | R | |
B44 - IO-Board F2 fuse fault (24V pH) | 44 | FC02 | uint16 | R | |
B45 - NT-Board F1 fuse fault (24V Sensoren) | 45 | FC02 | uint16 | R | |
B48 - pH regulation dynamic dosing exceeded | 48 | FC02 | uint16 | R | |
B50 - disinfection dynamic dosing exceeded | 50 | FC02 | uint16 | R | |
B51 - dosing OFF | 51 | FC02 | uint16 | R | |
B64 - disinfection dosing 24V | 64 | FC02 | uint16 | R | |
B65 - pH regulation dosing 24V | 65 | FC02 | uint16 | R | |
B66 - flocculation dosing | 66 | FC02 | uint16 | R | |
B18 - flocculation emty | 18 | FC02 | uint16 | R | |
B19 - flocculant leak | 19 | FC02 | uint16 | R | |
B68 - alarm | 68 | FC02 | uint16 | R | |
B70 - pH regulation dosing 230V | 70 | FC02 | uint16 | R | |
B71 - disinfection dosing 230V | 71 | FC02 | uint16 | R | |
C00 - pH control direction | 0 | FC01 | uint16 | R | |
C02 - flocculation ON_OFF | 2 | FC01 | uint16 | R | |
C03 - mutual locking ON_OFF | 3 | FC01 | uint16 | R | |
C16 - Modus Automatic_Menu | 16 | FC01 | uint16 | R | |
22 - pH | 22 | FC04 | float32 | pH | R |
24 - Redox | 24 | FC04 | float32 | mV | R |
36 - pH - setpoint | 36 | FC03 | float32 | R/W | |
40 - pH - alarm low | 40 | FC03 | float32 | R/W | |
42 - pH - alarm high | 42 | FC03 | float32 | R/W | |
44 - pH - time watch | 44 | FC03 | float32 | R/W | |
46 - pH - Control types | 46 | FC03 | float32 | R | |
48 - mV - setpoint | 48 | FC03 | float32 | R/W | |
50 - mV - p-range | 50 | FC03 | float32 | R/W | |
52 - mV - alarm low | 52 | FC03 | float32 | R/W | |
54 - mV - alarm high | 54 | FC03 | float32 | R/W | |
56 - mV - time watch | 56 | FC03 | float32 | R/W | |
58 - mV_ml - Control types | 58 | FC03 | float32 | R | |
114 - Dosing delay | 114 | FC03 | float32 | s | R/W |
ModbusCloud ist die Hardware- und Softwareplattform, mit der Installateure Modbus-Geräte aus einem Portal überwachen, visualisieren und steuern. Diese Vorlage ist eine von hunderten, die Sie sofort einsetzen können.

Peraqua
Controls salt electrolysis pool water treatment with real-time pH, ORP, and PPM monitoring.

Peraqua
Monitors pool water treatment parameters via RS485 for dosing systems

Peraqua
Controls a variable-speed pool pump via Modbus RTU for energy-efficient filtration

Peraqua
Monitors pool water chemistry and salt electrolysis parameters via RS485

Peraqua
Monitors pool water treatment parameters via RS485 interface

Komfovent
Controls Komfovent Domekt recuperator ventilation via Modbus TCP

Fronius
Monitors Fronius Symo and Primo inverters via Modbus TCP

NIBE

SunSpec

Victron

FoxESS