go-eCharger Home+
go-e GmbH
Controls and monitors go-eCharger Home+ EV wallbox charging sessions via Modbus TCP.
Overview
Key readings
- Car state
- Error code
- Total energy
- Total power
- Session energy charged
- Current L1 to L3

go-e GmbH
Controls and monitors go-eCharger Home+ EV wallbox charging sessions via Modbus TCP.
9 read / 3 write
| Name | Address | Function | Type | Unit | Access |
|---|---|---|---|---|---|
CAR_STATE Status PWM Signalisierung | 100 | FC04 | uint16 | R | |
ERROR Fehler | 107 | FC04 | uint16 | R | |
ENERGY_TOTAL Gesamt geladene Energiemenge | 128 | FC04 | uint32 | Wh | R |
POWER_TOTAL Leistung gesamt | 120 | FC04 | uint32 | W | R |
ENERGY_CHARGE Geladene Energiemenge | 132 | FC04 | uint32 | kW | R |
AMP_L1 Ampere auf L1 | 114 | FC04 | uint32 | A | R |
AMP_L2 Ampere auf L2 | 116 | FC04 | uint32 | A | R |
AMP_L3 Ampere auf L3 | 118 | FC04 | uint32 | A | R |
ADAPTER_INPUT Ladebox Adapter verbunden | 202 | FC04 | uint16 | R | |
ALLOW Erlaube Laden | 200 | FC06 | uint16 | W | |
AMPERE_VOLATILE Ampere Wert für die PWM | 299 | FC06 | uint16 | A | W |
ACCESS_STATE Zugangskontrolle | 201 | FC06 | uint16 | W |
ModbusCloud is the hardware-plus-software platform that installers use to monitor, visualise and control Modbus devices from one portal. This template is one of hundreds you can use right away.
Summer sale: 10% off with code SUMMER10
The pre-commissioning checklist for every RS485 bus. Print it and take it to site.
We send you the checklist plus an occasional practical Modbus tip. No spam, unsubscribe anytime.

Algodue Elettronica S.r.l.
Measures single-phase energy consumption and production via Modbus TCP.

Sigenergy

Fronius
Monitors and controls Fronius GEN24 inverters and PV batteries via SunSpec Modbus TCP

Huawei
Monitors HUAWEI SUN2000 inverter, LUNA2000 battery, and Smart Power Sensor via Modbus TCP.

NIBE

Fronius
Monitors Fronius Symo and Primo inverters via Modbus TCP