Fenecon Modbus templates
All 17 available Fenecon templates for ModbusCloud.
Monitor Fenecon Home, Commercial, and OpenEMS-based energy storage systems over Modbus TCP.
- Templates
- 17
- Connection
- Modbus TCP
- Registers
- 1 to 290 per template
- Compatible models
- Fenecon Pro Hybrid 10 · Modbus-API
- Last updated
Fenecon templates
17 via Modbus TCP
OpenEMSReads energy data from OpenEMS-based devices via Modbus TCPModbus TCP39 read, 0 write
Fenecon CommercialModbus TCP51 read, 5 write
Fenecon Commercial40Modbus TCP287 read, 3 write
Fenecon COMMERCIAL40 CHARGERModbus TCP56 read, 1 write
Fenecon Dess EssModbus TCP12 read, 0 write
Fenecon Dess GridMeterModbus TCP14 read, 0 write
Fenecon Dess PvMeterModbus TCP3 read, 0 write
Fenecon HomeModbus TCP23 read, 0 write
Fenecon MasterBox2V0 RelayModbus TCP6 read, 6 write
Fenecon Mini EssModbus TCP86 read, 11 write
Fenecon Mini GridMeterModbus TCP1 read, 0 write
Fenecon Mini PvMeterModbus TCP1 read, 0 write
FENECON Modbus-API (battery)Modbus TCP2 read, 0 write
FENECON Modbus-API (grid)Modbus TCP2 read, 0 write
FENECON Modbus-API (pv)Modbus TCP2 read, 0 write
Fenecon Pro EssModbus TCP63 read, 15 write
Fenecon Pro PvMeterModbus TCP9 read, 0 write
The scan recognises these devices
Connect them to RS485 or the network and start a scan in the portal.
Gateway
Portal
Incl. 4G data up to 30 MB per month
Excl. VAT. White label customer portal included. All prices
Order your first gateway100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

Fenecon builds energy management and battery storage systems for homes and commercial sites, built around the open-source OpenEMS platform. The templates here cover Fenecon Home, Fenecon Mini Ess, Fenecon Dess (including its grid meter and PV meter modules), Fenecon Commercial and Commercial40 (including the CHARGER and MasterBox2V0 Relay), plus the generic OpenEMS interface. That range reflects how Fenecon appears in the field: residential energy storage, commercial multi-cabinet installations, and integrator builds on top of OpenEMS.
ModbusCloud reads your Fenecon system over Modbus TCP and surfaces the energy data OpenEMS exposes — grid power, PV meter readings, battery state of charge, charge and discharge power, and relay states on the MasterBox2V0. For installers running multiple sites, the portal consolidates them into one overview with alert rules on grid import peaks, low battery SOC, or PV generation below a threshold you set. Because each Fenecon variant has its own template with the correct register addresses, you skip the OpenEMS register-channel translation that usually eats a commissioning afternoon.
All 14 Fenecon templates are free to browse. Import the one that matches your system into your ModbusCloud portal and read live data within minutes — no register mapping, no manufacturer PDFs.
What you can read out
- Grid import and export power
- PV meter generation
- Battery state of charge
- Battery charge and discharge power
- MasterBox relay states
Typical installations
- Residential Fenecon Home installations with PV and battery storage
- Commercial sites running Fenecon Commercial40 with charger and relay modules
- Integrator builds on OpenEMS consolidating multiple Fenecon sites