PCE PCE EV11.3 Modbus TCP template

PCE EV11.3

Monitors and controls PCE EV11.3 Wallbox charging via Modbus TCP.

Template for the PCE EV11.3 Wallbox over Modbus TCP. Reads charging state, current, power, temperature, and error codes. Allows control of charging current setpoint, max charging time, LED brightness, and automatic 1P/3P phase switching.

Protocol
Modbus TCP
Connection
Ethernet, Modbus TCP
Registers
17, read and write
Brand
PCE
Key readings
Charging current · Charging state · Charging relay state · Phase autoswitch status · Power meter · Temperature
Available commands
Charging current setpoint · Max charging time · LED brightness · Mode digital input
Compatible models
PCE EV11.3
Last updated

Registers (17)

11 read, 6 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
CHARGING_CURRENTARead
CHARGING_STATERead
CHARGING_RELAY_STATERead
PHASE_AUTOSWITCHRead
POWERMETER_0Read
ERRORRead
CHARGING_TIMERead
TEMPERATURERead
PWM_IN_MAX_Read
RCD_CURRENT_DCRead
RCD_CURRENT_ACTUELRead
CHARGING_CURRENTWrite
HEARTBEATWrite
CHARGING_CURRENT_OFFLINEWrite
MAX_CHARGING_TIMEWrite
LED_BRIGHTNESSWrite
MODE_DIGITAL_INWrite

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Monitor real-time charging current, power consumption, and temperature on a cloud dashboard for each customer site.
  • Set the maximum charging current remotely to match available grid capacity or solar production.
  • Create an alert when the wallbox reports an error code or when internal temperature exceeds a safe threshold.
  • Enforce a maximum charging time per session to manage energy costs across multiple wallbox installations.
  • Track phase autoswitch status to verify that 1P/3P switching is active and functioning correctly.
  • Adjust LED brightness remotely for installations in light-sensitive environments such as residential garages.

Installation

  1. Connect the PCE EV11.3 to the local network and verify that Modbus TCP is reachable on its configured IP address and port.

  2. If automatic 1P/3P phase switching is required, activate the designated DIP switch on the internal circuit board of the wallbox before closing the enclosure.

  3. Wire the ModbusCloud Gateway to the same local network as the wallbox, ensuring both devices can communicate over TCP.

  4. Import the PCE EV11.3 template in the ModbusCloud platform and assign the correct IP address and Modbus unit ID to the device.

  5. Verify communication by checking live register values for charging state, current, and temperature on the ModbusCloud dashboard.

  6. Configure desired polling intervals and set up alerts or control actions as needed for your project.

Things to watch for

The phase autoswitch status always shows fixed mode. How do I enable automatic 1P/3P switching?

You must activate the designated DIP switch on the internal circuit board of the PCE EV11.3. Without this physical switch enabled, the wallbox will not perform automatic phase switching and remains in fixed phase mode.

I cannot reach the wallbox over Modbus TCP. What should I check?

Confirm the wallbox is connected to the local network and that the IP address and TCP port match the settings in ModbusCloud. Check that no firewall or VLAN isolation is blocking communication between the gateway and the wallbox.

Charging current setpoint does not seem to take effect. What could be wrong?

Ensure that the wallbox is in a state that accepts remote setpoints, for example not in an error state or mid-session lockout. Also verify that the Modbus unit ID and register addresses match the official PCE EV11.3 register map.

Temperature readings seem unusually high. Is this normal?

The temperature register reflects the internal temperature of the wallbox electronics, not ambient temperature. High values can occur during prolonged high-power charging sessions. If values exceed the manufacturer's specification, inspect ventilation and mounting conditions.