Bender CC613

Charge controller for AC wallboxes with charging state, meter values and a writable current limit.

The Bender CC613 is a charge controller that runs AC wallboxes and charging stations and measures charging power and energy through its meter. This Modbus TCP template reads charging state, meter values, session data and load management values and lets you set the charging current limit and availability from ModbusCloud.

Protocol
Modbus TCP
Connection
Ethernet, Modbus TCP
Registers
64, read and write
Brand
Bender
Key readings
Vehicle state · Charge point status · Charging power · Energy · Phase currents · Session energy
Available commands
Charging current limit · Charge point availability · Safe current · Load management limits
Compatible models
CC613 · CC612 · Wallboxes with a Bender CC612 or CC613 charge controller
Last updated

Registers (64)

63 read, 9 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Vehicle StateRead
OCPP Charge Point StatusRead
Total Active PowerWRead
Total EnergyWhRead
Current L1ARead
Current L2ARead
Current L3ARead
Voltage L1VRead
Voltage L2VRead
Voltage L3VRead
Power L1WRead
Power L2WRead
Power L3WRead
Energy L1WhRead
Energy L2WhRead
Energy L3WhRead
Signaled CurrentRead
Charged Energy SessionWhRead
Charge Duration SessionsRead
Charged Energy Session 16-bitWhRead
Charge Duration Session 16-bitsRead
Relay StateRead
Plug Lock StatusRead
Error Codes 1Read
Error Codes 2Read
Error Codes 3Read
Error Codes 4Read
Max Current EVRead
Minimum Current LimitRead
Operator Current LimitARead
EV Battery State%Read
Smart Vehicle DetectedRead
HEMS Current LimitARead and write
Charge Point AvailabilityRead and write
Safe CurrentRead and write
Communication TimeoutRead and write
Modbus Address OffsetRead and write
DLM ModeRead
DLM Sub-Distribution Limit L1ARead
DLM Sub-Distribution Limit L2ARead
DLM Sub-Distribution Limit L3ARead
DLM Operator Limit L1ARead and write
DLM Operator Limit L2ARead and write
DLM Operator Limit L3ARead and write
DLM External Meter SupportRead
DLM Connected SlavesRead
DLM Current Applied L1ARead
DLM Current Applied L2ARead
DLM Current Applied L3ARead
DLM Current Available L1ARead
DLM Current Available L2ARead
DLM Current Available L3ARead
EV Required Energy 15118Read
EV Required Energy 15118 32-bitRead
Scheduled Departure TimeRead
Scheduled Departure DateRead
Session Start TimeRead
Session End TimeRead
Firmware VersionRead
Protocol VersionRead
Charge Point ModelRead
ID TagRead
EVCCIDRead
Write ID TagWrite

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Use cases

  • Show charging power, session energy and vehicle state of each charging point on a ModbusCloud dashboard.
  • Get an email alert when the charge point reports a fault or the error codes are not zero.
  • Keep a year of energy history per charging point to settle charging costs per month.
  • Lower the charging current limit from ModbusCloud when the building connection is near its limit.
  • Check the load management values of a charging park and see how much current each phase has left.

Installation

  1. Connect the Ethernet port of the wallbox or charge controller to the same network as the ModbusCloud Gateway.

  2. In the controller web interface, enable the Modbus TCP server and select the register set Ebee, Bender, MENNEKES.

  3. Note the IP address of the controller; charging point 1 uses port 502, charging point 2 port 503.

  4. In ModbusCloud, add a Modbus TCP device with that IP address and port and import this template.

  5. Check that vehicle state and charge point status change when you plug in a vehicle.

Things to watch for

All meter values show 4294967295. What is wrong?

That is 0xFFFFFFFF, the value the controller sends when no meter is present or the value is not available. Check that a meter is built in and configured, and that your meter type supports per phase values. Voltages and total power need controller software 5.22 or later.

Why does the controller not answer on Modbus TCP?

The Modbus TCP server is off by default. Enable it in the controller settings and choose the register set Ebee, Bender, MENNEKES, not Phoenix or TQ-DM100. For the second charging point of a twin station use port 503.

Why does the car charge with less current than the limit I wrote?

The HEMS current limit is an upper limit. The signalled current can be lower because of the cable, the vehicle or dynamic load management. Writing 0 pauses the session. If the energy manager stops writing, the controller can fall back to the safe current after the communication timeout.

Is it safe to write the other settings?

Write with care. Changing Modbus Address Offset moves every register, so the template no longer matches. Charge Point Availability uses inverted values before software 5.22. Write ID Tag starts or stops a session like an RFID card and only works when the controller allows it.