Atmoce Modbus templates
All 4 available Atmoce templates for ModbusCloud.
Monitor Atmoce module inverters and AC-coupled batteries through one ModbusCloud dashboard.
- Templates
- 4
- Connection
- Modbus RTU and TCP
- Registers
- 2 to 38 per template
- Last updated
Atmoce templates
1 via Modbus RTU, 3 via Modbus TCP
Atmoce AC Battery and Module-InverterControls and monitors Atmoce module-inverters and AC coupled batteries via Modbus RTU.Modbus RTU38 read, 7 write
Atmoce MG100 M-gateway (battery)Modbus TCP3 read, 3 write
Atmoce MG100 M-gateway (grid)Modbus TCP8 read, 0 write
Atmoce MG100 M-gateway (pv)Modbus TCP2 read, 0 write
The scan recognises these devices
Connect them to RS485 or the network and start a scan in the portal.
Gateway
Portal
Incl. 4G data up to 30 MB per month
Excl. VAT. White label customer portal included. All prices
Order your first gateway100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

Atmoce makes AC-coupled battery systems, module-inverters, and the MG100 M-gateway used to connect them into a solar installation. These are the kind of devices you find in residential retrofits where a homeowner adds storage after the PV system is already running, and the installer needs to bring battery, grid, and PV telemetry into a single view. If you install or service Atmoce equipment, the gateway is usually the tidiest point to read everything at once.
ModbusCloud templates cover the Atmoce AC Battery, the module-inverter, and the MG100 gateway roles for battery, grid, and PV. Over Modbus RTU you read state of charge, charge and discharge power, grid import and export, PV input power, and inverter control state. That gives you the data to set alert rules on a low state of charge or a PV input that drops below a threshold you set, without logging into the installer app for each site.
All four Atmoce templates are free to browse. Import one into your ModbusCloud portal and read live data within minutes — no register hunting through manufacturer PDFs.
What you can read out
- Battery state of charge
- Battery charge and discharge power
- Grid import and export power
- PV input power to the inverter
- Module-inverter control state
Typical installations
- Residential PV retrofits where an Atmoce battery is added after the array
- Homes with AC-coupled storage read through the MG100 M-gateway over RS485
- Installer portfolios tracking Atmoce fleets for warranty and service response
Want to see how it works?