M-TEC M-TEC Energy Butler Modbus RTU template

M-TEC Energy Butler

Monitors M-TEC Energy Butler battery and power metrics via Modbus

This template reads battery and power data from the M-TEC Energy Butler via Modbus TCP. It provides state of charge, voltage, current, temperature, BMS status, grid and PV power readings, and fault flags. Designed for Gen3 devices, it can be adapted for Gen2 with minor register changes.

Protocol
Modbus RTU
Connection
RS485, 9600 baud
Registers
15, read only
Brand
M-TEC
Key readings
State of Charge (SOC) · Battery Voltage, Current, Temperature · BMS State, Error, Warning · AC Power Grid and Backup · PV Power and Power Meter · Fault FLAG1 and FLAG2
Compatible models
M-TEC Energy Butler
Last updated

Registers (15)

15 read, 0 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
State of Charge (SOC)%Read
Battery VoltageVRead
Battery CurrentARead
Battery Temperatur°CRead
BMS StateRead
BMS ErrorRead
BMS WarningRead
AC Power GridkWRead
AC Power BackupkWRead
PV PowerkWRead
Power MeterkWRead
Battery PowerkWRead
Running StateRead
Fault FLAG1Read
Fault FLAG2Read

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Monitor battery state of charge and voltage trends on a live dashboard for residential energy storage customers.
  • Create an alert when BMS error or warning flags are raised to enable fast remote troubleshooting.
  • Track PV power production and grid power exchange over time to optimize self-consumption rates.
  • Log fault FLAG1 and FLAG2 values historically to identify recurring issues in the M-TEC Energy Butler system.
  • Compare battery temperature readings against ambient conditions to detect cooling or ventilation problems.

Installation

  1. Connect the ModbusCloud gateway to the M-TEC Energy Butler's Multi-Funktion Port connector using the appropriate cabling.

  2. Configure the Modbus communication settings on the gateway: 9600 baud, 1 stop bit, no parity, and auto timing.

  3. Verify the Modbus TCP connection by reading a known register such as the state of charge (SOC) value.

  4. Import the M-TEC Energy Butler template in the ModbusCloud platform and assign it to the connected gateway.

  5. If using a Gen2 device, replace the register addresses in the template with the corresponding start registers from chapter 4 of the M-TEC documentation.

  6. Confirm that all readings, including battery metrics, power values, and fault flags, appear correctly on the ModbusCloud dashboard.

Things to watch for

How do I know if my M-TEC Energy Butler is Gen2 or Gen3?

Refer to chapter 2 of the M-TEC Modbus documentation, which explains how to identify the hardware generation. The register addresses differ between Gen2 and Gen3 devices.

Why are some register values showing as zero or incorrect?

Some registers use int32 or uint32 data types that span two consecutive Modbus addresses. Verify that your register mapping accounts for both addresses and uses the correct byte order.

What baud rate and parity settings does the M-TEC Energy Butler require?

Set the baud rate to 9600, stop bits to 1, parity to none, and timing to auto. Incorrect settings will prevent communication.

Can I use this template for a Gen2 Energy Butler without modifications?

No. The template is designed for Gen3 devices. For Gen2, you must replace the register addresses with the corresponding start registers listed in chapter 4 of the M-TEC documentation.

Want to see how it works?