Stiebel Eltron Stiebel Eltron Heating & Cooling Modbus TCP template

Stiebel Eltron Heating & Cooling

Controls Stiebel Eltron heat pumps via Modbus TCP through the ISG Web gateway.

This template connects Stiebel Eltron heat pumps (WPM, WPL, LPZ series) to ModbusCloud via Modbus TCP through the ISG Web gateway. It reads temperatures, operating modes, and fault states, and allows control of room and hot water temperature setpoints.

Protocol
Modbus TCP
Connection
Ethernet, Modbus TCP
Registers
22, read and write
Key readings
Outside temperature · Supply flow temperature HC1/HC2 · Buffer temperature (actual/target) · Hot water storage temperature · Heatpump error and fault number · Heatpump operating mode
Available commands
Heatpump operating mode · Comfort/Eco room temperature HC1/HC2 · Hot water comfort/eco temperature
Compatible models
WPM · LPZ · WPL · ISG Web
Last updated

Registers (22)

20 read, 7 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
519 - State Target Buffer temperature°CRead
518 - Actual Buffer temperature°CRead
513 - Actual Supply Flowtemperature Heatpump°CRead
508 - Actual Supply Flowtemperature HC1°CRead
516 - Actual Return Flowtemperature Heatpump°CRead
510 - State Target Supply Flowtemperature HC1°CRead
2504 - State Heatpump ErrorRead
1501 - State Heatpump Operating modeRead and write
1504 - State Heating Curve HC1Read
2508 - State Heatpump FaultnumberRead
522 - Actual Hot Water Storage temperature°CRead
523 - State Target Hot Water Storage temperature°CRead
507 - Actual Outsidetemperature°CRead
511 - Actual Supply Flowtemperature HC2°CRead
512 - State Target Supply Flowtemperature HC2°CRead
1502 - State Comfort Roomtemperature HC1°CRead and write
1505 - State Comfort Roomtemperature HC2°CRead and write
1503 - State Eco Roomtemperature HC1°CRead and write
1506 - State Eco Roomtemperature HC2°CRead and write
1507 - State Heating Curve HC2Read
1511 - Hot Water Eco temperature°CWrite
1510 - Hot Water Comfort temperature°CWrite

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Monitor outside temperature, flow temperatures, and buffer tank status on a live cloud dashboard for your customer.
  • Create an alert when a heat pump fault or error state is detected to reduce response time for service calls.
  • Adjust room temperature comfort and eco setpoints remotely to match occupancy schedules or seasonal changes.
  • Integrate hot water temperature control with PV surplus availability to optimize self-consumption of solar energy.
  • Track heating circuit operating modes over time using historical data to verify system efficiency and runtime balance.
  • Compare actual buffer temperature against target values to identify control deviations early.

Installation

  1. Connect the Stiebel Eltron ISG Web gateway to your local network and ensure the Modbus TCP interface is enabled (upgrade firmware or purchase the software update if required).

  2. Connect your ModbusCloud Gateway to the same local network as the ISG Web device.

  3. Note the IP address of the ISG Web and confirm it is reachable from the ModbusCloud gateway.

  4. Import the Stiebel Eltron Heating and Cooling template in the ModbusCloud portal and assign the correct IP address and Modbus TCP port (default 502).

  5. Verify that register readings such as outside temperature and buffer temperature appear correctly on the ModbusCloud dashboard.

  6. Test a writable control, such as changing the hot water comfort temperature setpoint, and confirm the change is reflected on the ISG Web display.

Things to watch for

Do I need a separate software update for the ISG Web to use Modbus TCP?

Older ISG Web versions require a chargeable software update from Stiebel Eltron to activate the Modbus TCP interface. Newer ISG Web models have this interface built in. Check with your Stiebel Eltron distributor before purchasing.

Why are my temperature readings off by one register?

Stiebel Eltron documentation lists register numbers that are offset by 1 from the actual Modbus addresses. Register 519 in the manual corresponds to address 518. The template already accounts for this offset.

Which Stiebel Eltron models are supported by this template?

The template is designed for WPM (version 3 and above), WPL, and LPZ series heat pumps connected through the ISG Web gateway. Verify ISG compatibility with your specific model before installation.

What data format do the temperature registers use?

Temperature registers use uint16 or int16 format and report values in degrees Celsius. No additional scaling factor is needed for most registers.