WEG CFW11

Frequency inverter for three-phase motors: speed, current, power, faults and every drive parameter.

The WEG CFW11 is a frequency inverter that controls the speed and torque of three-phase induction and permanent magnet motors in pumps, fans, compressors and machines. This Modbus RTU template reads speed, current, power, temperatures and faults, and lets you write the control word, speed reference, ramps and drive parameters from ModbusCloud.

Protocol
Modbus RTU
Connection
RS485, 9600 baud
Registers
602, read and write
Brand
WEG
Key readings
Motor speed · Motor current · Output power · Motor torque · DC link voltage · Heatsink temperature · Present fault and alarm · Drive status
Available commands
Run, stop and direction · Speed reference · Acceleration and deceleration time · Minimum and maximum speed · PID setpoint · Digital and analog outputs
Compatible models
CFW-11 · CFW-11M
Last updated

Registers (602)

602 read, 431 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Motor SpeedrpmRead2FC03uint16
Motor CurrentARead3FC03uint16
Motor FrequencyHzRead5FC03uint16
DC Link Voltage (Ud)VRead4FC03uint16
Motor VoltageVRead7FC03uint16
Motor Torque%Read
Output PowerkWRead
Output Cos phiRead
Speed ReferencerpmRead
VFD StatusRead
Present AlarmRead
Present FaultRead
IGBTs Temperature U°CRead
IGBTs Temperature V°CRead
IGBTs Temperature W°CRead
Rectifier Temperature°CRead
Internal Air Temp.°CRead
Control Air Temperature°CRead
Fan Heatsink SpeedrpmRead
Motor Overload Status%Read
Time PoweredhRead
Time EnabledhRead
kWh Output EnergykWhRead
Fan Enabled TimehRead
Logical StatusRead
Speed in 13 bitsRead
Serial/USB ControlRead and write
Serial/USB Speed Ref.Read and write
Access to ParametersRead and write
DI8 to DI1 StatusRead
DO5 to DO1 StatusRead
AO1 Value%Read
AO2 Value%Read
AO3 Value%Read
AO4 Value%Read
AI1 Value%Read
AI2 Value%Read
AI3 Value%Read
AI4 Value%Read
Software VersionRead
DI16 to DI9 StatusRead
DO13 to DO6 StatusRead
Accessories Config. 1Read
Accessories Config. 2Read
Power Hardware ConfigRead
Encoder SpeedrpmRead
Encoder Pulses CountRead
PID Process Variable%Read
PID Setpoint Value%Read
Last FaultRead
Last Fault Day/MonthRead
Last Fault YearRead
Last Fault TimeRead
Second FaultRead
Second Flt. Day/MonthRead
Second Fault YearRead
Second Fault TimeRead
Third FaultRead
Third Fault Day/MonthRead
Third Fault YearRead
Third Fault TimeRead
Fourth FaultRead
Fourth Flt. Day/MonthRead
Fourth Fault YearRead
Fourth Fault TimeRead
Fifth FaultRead
Fifth Fault Day/MonthRead
Fifth Fault YearRead
Fifth Fault TimeRead
Sixth FaultRead
Sixth Fault Day/MonthRead
Sixth Fault YearRead
Sixth Fault TimeRead
Seventh FaultRead
Seventh Flt.Day/MonthRead
Seventh Fault YearRead
Seventh Fault TimeRead
Eighth FaultRead
Eighth Flt. Day/MonthRead
Eighth Fault YearRead
Eighth Fault TimeRead
Ninth FaultRead
Ninth Fault Day/MonthRead
Ninth Fault YearRead
Ninth Fault TimeRead
Tenth FaultRead
Tenth Fault Day/MonthRead
Tenth Fault YearRead
Tenth Fault TimeRead
Current At Last FaultARead
DC Link At Last FaultVRead
Speed At Last FaultrpmRead
Reference Last FaultrpmRead
Frequency Last FaultHzRead
Motor Volt.Last FaultVRead
DIx Status Last FaultRead
DOx Status Last FaultRead
Acceleration TimesRead and write
Deceleration TimesRead and write
Acceleration Time 2sRead and write
Deceleration Time 2sRead and write
S RampRead and write
1st/2nd Ramp Select.Read and write
Speed Ref. BackupRead and write
Keypad ReferencerpmRead and write
JOG/JOG+ ReferencerpmRead and write
JOG- ReferencerpmRead and write
Multispeed Ref. 1rpmRead and write
Multispeed Ref. 2rpmRead and write
Multispeed Ref. 3rpmRead and write
Multispeed Ref. 4rpmRead and write
Multispeed Ref. 5rpmRead and write
Multispeed Ref. 6rpmRead and write
Multispeed Ref. 7rpmRead and write
Multispeed Ref. 8rpmRead and write
Max. Overspeed Level%Read and write
Minimum SpeedrpmRead and write
Maximum SpeedrpmRead and write
Max. Output CurrentARead and write
Manual Torque BoostRead and write
Autom. Torque BoostRead and write
Slip Compensation P0138%Read and write
Output Current FiltersRead and write
Dwell Time At StartsRead and write
Dwell Speed At StartrpmRead and write
Max. Output Voltage P0142%Read and write
Interm.Output Voltage%Read and write
3Hz Output Voltage%Read and write
Field Weakening SpeedrpmRead and write
Intermediate SpeedrpmRead and write
DC Regul. Type V/fRead and write
DC Regul. Level V/fVRead and write
DC Link Regul. P GainRead and write
Dyn. Braking LevelVRead and write
Dyn. Braking ResistorΩRead and write
Dyn. B. Resist. PowerkWRead and write
Overl.Curr.100% SpeedARead and write
Overl.Curr. 50% SpeedARead and write
Overl.Curr. 5% SpeedARead and write
Motor Thermal ClassRead and write
Speed Regul. ConfigurationRead and write
Speed Prop. GainRead and write
Speed Integral GainRead and write
LOC Reference OffsetRead and write
REM Reference OffsetRead and write
Speed FiltersRead and write
Speed Diff. GainRead and write
Current Prop. GainRead and write
Current Integral GainRead and write
Max. + Torque Curr.%Read and write
Max. - Torque Curr.%Read and write
Min. Torque Curr.%Read and write
Flux Proport. GainRead and write
Flux Integral GainRead and write
Minimum Flux%Read and write
Rated Flux%Read and write
Iq* After I/f%Read and write
Magnetization ModeRead and write
Speed for I/F Activ.rpmRead and write
Current in I/F ModeRead and write
DC Link Regul. ModeRead and write
DC Link Regul. LevelVRead and write
DC Link Prop. GainRead and write
DC Link Integral GainRead and write
Voltage Proport. GainRead and write
Voltage Integral GainRead and write
Max. Output Voltage P0190VRead and write
Encoder Zero SearchRead and write
Status Encoder Zero SearchRead
Day of the WeekRead and write
DayRead and write
MonthRead and write
YearRead and write
HourRead and write
MinutesRead and write
SecondsRead and write
PasswordRead and write
LanguageRead and write
Type of ControlRead and write
Special Function Sel.Read and write
Load/Save ParametersRead and write
Read Parameter Sel. 1Read and write
Read Parameter Sel. 2Read and write
Read Parameter Sel. 3Read and write
Ref. Scale FactorRead and write
Ref. Eng. Unit 1Read and write
Ref. Eng. Unit 2Read and write
Ref. Eng. Unit 3Read and write
Ref. Decimal PointRead and write
Full Scale Read 1%Read and write
Full Scale Read 2%Read and write
Full Scale Read 3%Read and write
HMI Display ContrastRead and write
Zero Speed DisableRead and write
Zero Speed Dis. OutRead and write
Zero Speed TimesRead and write
LOC/REM Selection SrcRead and write
LOC Reference Sel.Read and write
REM Reference Sel.Read and write
LOC FWD/REV SelectionRead and write
LOC Run/Stop Sel.Read and write
LOC JOG SelectionRead and write
REM FWD/REV Sel.Read and write
REM Run/Stop Sel.Read and write
REM JOG SelectionRead and write
Stop Mode SelectionRead and write
Dead Zone (AIs)Read and write
AI1 Signal FunctionRead and write
AI1 GainRead and write
AI1 Signal TypeRead and write
AI1 Offset%Read and write
AI1 FiltersRead and write
AI2 Signal FunctionRead and write
AI2 GainRead and write
AI2 Signal TypeRead and write
AI2 Offset%Read and write
AI2 FiltersRead and write
AI3 Signal FunctionRead and write
AI3 GainRead and write
AI3 Signal TypeRead and write
AI3 Offset%Read and write
AI3 FiltersRead and write
AI4 Signal FunctionRead and write
AI4 GainRead and write
AI4 Signal TypeRead and write
AI4 Offset%Read and write
AI4 FiltersRead and write
AO1 FunctionRead and write
AO1 GainRead and write
AO1 Signal TypeRead and write
AO2 FunctionRead and write
AO2 GainRead and write
AO2 Signal TypeRead and write
AO3 FunctionRead and write
AO3 GainRead and write
AO3 Signal TypeRead and write
AO4 FunctionRead and write
AO4 GainRead and write
AO4 Signal TypeRead and write
DI1 FunctionRead and write
DI2 FunctionRead and write
DI3 FunctionRead and write
DI4 FunctionRead and write
DI5 FunctionRead and write
DI6 FunctionRead and write
DI7 FunctionRead and write
DI8 FunctionRead and write
Filter for Torque Current - IqsRead and write
Hysteresis for Torque Current Iq%Read and write
DO1 Function (RL1)Read and write
DO2 Function (RL2)Read and write
DO3 Function (RL3)Read and write
DO4 FunctionRead and write
DO5 FunctionRead and write
Fx FrequencyHzRead and write
Fx HysteresisHzRead and write
DO2 ON TimesRead and write
DO2 OFF TimesRead and write
DO3 ON TimesRead and write
DO3 OFF TimesRead and write
Nx/Ny HysteresisrpmRead and write
Nx SpeedrpmRead and write
Ny SpeedrpmRead and write
Ix CurrentARead and write
Zero Speed ZonerpmRead and write
N = N* BandrpmRead and write
Tx Torque%Read and write
Hx TimehRead and write
ND/HD VFD Rated Curr.Read
Line Rated VoltageRead and write
Switching FrequencyRead and write
ApplicationRead and write
DC-Braking Start TimesRead and write
DC-Braking Stop TimesRead and write
DC-Braking SpeedrpmRead and write
DC-Braking Voltage%Read and write
Skip Speed 1rpmRead and write
Skip Speed 2rpmRead and write
Skip Speed 3rpmRead and write
Skip BandrpmRead and write
Serial AddressRead and write
Serial Baud RateRead and write
Serial Bytes Config.Read and write
Serial ProtocolRead and write
Comm. Error ActionRead and write
Serial WatchdogsRead and write
Serial Interf. StatusRead
Oriented Start-upRead and write
Copy Function MemCardRead and write
Copy Function HMIRead and write
FlyStart/Ride-ThroughRead and write
DC Link Power LossVRead and write
DC Link Ride-ThroughVRead and write
DC Link Power BackVRead and write
Ride-Through P GainRead and write
Ride-Through I GainRead and write
F.S. Current Ramp I/fsRead and write
Flying Start FiltersRead and write
Frequency Ramp F.S.Read and write
Voltage RampsRead and write
Dead TimesRead and write
Auto-Reset TimesRead and write
V/f Outp. Volt. Comp.Read and write
Motor Unbal.Curr.ConfRead and write
Ground Fault Config.Read and write
Current Lim. Conf.Read and write
Motor Overload Conf.Read and write
Ixt Alarm Level%Read and write
IGBTs Overload Conf.Read and write
Motor Overtemp. Conf.Read and write
Fan Control Config.Read and write
IGBTs/Air Overtmp.CfgRead and write
Fan Speed Fault Config.Read and write
F185 Fault ConfigurationRead and write
Dead Time Compens.Read and write
Line Phase Loss TimesRead and write
Encoder Fault Config.Read and write
Motor Current Stabil.Read and write
Temp. Imb. Conf.Read and write
Stop Engine Fail TimesRead and write
DC-Braking Curr Sless%Read and write
PTC1 Type SensorRead and write
Sensor 1 F/A Conf.Read and write
Temper. F/A Sensor 1°CRead and write
PTC2 Type SensorRead and write
Sensor 2 F/A Conf.Read and write
Temper. F/A Sensor 2°CRead and write
PTC3 Type SensorRead and write
Sensor 3 F/A Conf.Read and write
Temper. F/A Sensor 3°CRead and write
PTC4 Type SensorRead and write
Sensor 4 F/A Conf.Read and write
Temper. F/A Sensor 4°CRead and write
PTC5 Type SensorRead and write
Sensor 5 F/A Conf.Read and write
Temper. F/A Sensor 5°CRead and write
Temperature Sensor 1°CRead
Temperature Sensor 2°CRead
Temperature Sensor 3°CRead
Temperature Sensor 4°CRead
Temperature Sensor 5°CRead
Highest Temp. Sens.°CRead
Cable Alarm Temper.°CRead and write
Slip Compensation P0397Read and write
Motor Service FactorRead and write
Motor Rated Eff.%Read and write
Motor Rated VoltageVRead and write
Motor Rated CurrentARead and write
Motor Rated SpeedrpmRead and write
Motor Rated FrequencyHzRead and write
Motor Rated PowerRead and write
Encoder Pulses NumberRead and write
Motor VentilationRead and write
Motor Rated Power FacRead and write
Run Self-TuningRead and write
Stator ResistanceΩRead and write
Magnetization CurrentARead and write
Leakage InductanceRead and write
Tr Time ConstantsRead and write
Tm Time ConstantsRead and write
Motor Magnetization TimesRead and write
Type PMRead and write
Pole NumberRead and write
Lq InductanceRead and write
Ld InductanceRead and write
Ke ConstantRead and write
Iq Prop. GainRead and write
Iq Integral GainRead and write
Id Prop. GainRead and write
Id Integral GainRead and write
Inductance Lq CTRead and write
Inductance Ld CTRead and write
Constant Ke CTRead and write
PID Proportional GainRead and write
PID Integral GainRead and write
PID Differential GainRead and write
PID Ramp TimesRead and write
PID Feedback Sel.Read and write
Keypad PID Setpoint%Read and write
PID Action TypeRead and write
Proc. V. Scale FactorRead and write
Proc.V. Decimal PointRead and write
Proc. V. Eng. Unit 1Read and write
Proc. V. Eng. Unit 2Read and write
Proc. V. Eng. Unit 3Read and write
PVx Value%Read and write
PVy Value%Read and write
Wake Up Band%Read and write
P0525 Autom. SettingRead and write
Hysteresis VPx/VPy%Read and write
Trigger Signal SourceRead and write
Trigger Level%Read and write
Trigger ConditionRead and write
Trace Sampling PeriodRead and write
Trace Pre-Trigger%Read and write
Trace Max. Memory%Read and write
Trace Avail. Memory%Read
Trace Channel 1 (CH1)Read and write
Trace Channel 2 (CH2)Read and write
Trace Channel 3 (CH3)Read and write
Trace Channel 4 (CH4)Read and write
Start Trace FunctionRead and write
Trace Trig. Day/MonthRead
Trace Trig. YearRead
Trace Trig. TimeRead
Trace Trig. SecondsRead
Trace Function StatusRead
Energy Saving Config.Read and write
Cos Phi ReferenceRead and write
Energy Sav. Max. Torq%Read and write
Energy Sav. Min. Volt/Flux%Read and write
Energy Sav. Min. Sp.rpmRead and write
Energy Sav. Hysteresis%Read and write
Firmware UpdateRead and write
Firmware RevisionRead
Revision of the PLDRead
CO/DN/DP ControlRead
CO/DN/DP Speed RefRead
Anybus-CC ControlRead
Anybus-CC Speed Ref.Read
Operating Mode StatesRead
DOx ValueRead and write
AOx Value 1Read and write
AOx Value 2Read and write
AOx Value 3Read and write
AOx Value 4Read and write
CAN ProtocolRead and write
CAN AddressRead and write
CAN Baud RateRead and write
Bus Off ResetRead and write
CAN Controller StatusRead
RX CAN TelegramsRead
TX CAN TelegramsRead
Bus Off CounterRead
CAN Lost MessagesRead
DNet I/O instancesRead and write
DNet Read Word #3Read and write
DNet Read Word #4Read and write
DNet Read Word #5Read and write
DNet Read Word #6Read and write
DNet Write Word #3Read and write
DNet Write Word #4Read and write
DNet Write Word #5Read and write
DNet Write Word #6Read and write
DNet Network StatusRead
DNet Master StatusRead
CANopen Comm. StatusRead
CANopen Node StateRead
Anybus IdentificationRead
Anybus Comm. StatusRead
Anybus AddressRead and write
Anybus Baud RateRead and write
Anybus I/O WordsRead and write
Anybus Read Word #3Read and write
Anybus Read Word #4Read and write
Anybus Read Word #5Read and write
Anybus Read Word #6Read and write
Anybus Read Word #7Read and write
Anybus Read Word #8Read and write
Anybus Write Word #3Read and write
Anybus Write Word #4Read and write
Anybus Write Word #5Read and write
Anybus Write Word #6Read and write
Anybus Write Word #7Read and write
Anybus Write Word #8Read and write
Profibus Comm. StatusRead
Profibus Data ProfileRead and write
Profibus Reading Word #3Read and write
Profibus Reading Word #4Read and write
Profibus Reading Word #5Read and write
Profibus Reading Word #6Read and write
Profibus Reading Word #7Read and write
Profibus Reading Word #8Read and write
Profibus Reading Word #9Read and write
Profibus Reading Word#10Read and write
Profibus Writing Word#3Read and write
Profibus Writing Word#4Read and write
Profibus Writing Word#5Read and write
Profibus Writing Word#6Read and write
Profibus Writing Word#7Read and write
Profibus Writing Word#8Read and write
Profibus Writing Word#9Read and write
Profibus Writing Word#10Read and write
PROFIdrive Output IRead and write
PROFIdrive Active PRead and write
PROFIdrive Torque ValRead and write
PROFIdrive SW NAMURRead and write
Delay Update I/ORead and write
Phase U Book 1 Temperature°CRead
Phase V Book 1 Temperature°CRead
Phase W Book 1 Temperature°CRead
Phase U Book 2 Temperature°CRead
Phase V Book 2 Temperature°CRead
Phase W Book 2 Temperature°CRead
Phase U Book 3 Temperature°CRead
Phase V Book 3 Temperature°CRead
Phase W Book 3 Temperature°CRead
Phase U Book 4 Temperature°CRead
Phase V Book 4 Temperature°CRead
Phase W Book 4 Temperature°CRead
Phase U Book 5 Temperature°CRead
Phase V Book 5 Temperature°CRead
Phase W Book 5 Temperature°CRead
Current U-B1/IGBT U1ARead
Current V-B1/IGBT V1ARead
Current W-B1/IGBT W1ARead
Current U-B2/IGBT U2ARead
Current V-B2/IGBT V2ARead
Current W-B2/IGBT W2ARead
Current U-B3/IGBT U3ARead
Current V-B3/IGBT V3ARead
Current W-B3/IGBT W3ARead
Current U-B4/IGBT U4ARead
Current V-B4/IGBT V4ARead
Current W-B4/IGBT W4ARead
Current U-B5/IGBT U5ARead
Current V-B5/IGBT V5ARead
Current W-B5/IGBT W5ARead
DIM1 FunctionRead and write
DIM2 FunctionRead and write
DIM1 DIM2 StatusRead
Ret. Temp. Phase R°CRead
Ret. Temp. Phase S°CRead
Ret. Temp. Phase T°CRead
Anybus StatusRead and write
Eth:Baud rateRead and write
Eth:ModbusTCP timeoutRead and write
Eth:IP Address ConfigRead and write
Eth:IP Address 1Read and write
Eth:IP Address 2Read and write
Eth:IP Address 3Read and write
Eth:IP Address 4Read and write
CIDRRead and write
Gateway 1Read and write
Gateway 2Read and write
Gateway 3Read and write
Gateway 4Read and write
Station NameRead and write
Compatible modeRead and write
Profibus AddressRead and write
Profibus Teleg. Sel.Read and write
Fault Message CounterRead
Fault NumberRead
Profibus Baud RateRead
Drive Unit Ident.Read
Profile Ident. NumberRead
Control Word PROFIdriveRead
Status Word PROFIdriveRead
SoftPLC StatusRead
SoftPLC CommandRead and write
Scan Cycle TimemsRead
SoftPLC SupervisionRead and write
SoftPLC Parameter 1Read and write
SoftPLC Parameter 2Read and write
SoftPLC Parameter 3Read and write
SoftPLC Parameter 4Read and write
SoftPLC Parameter 5Read and write
SoftPLC Parameter 6Read and write
SoftPLC Parameter 7Read and write
SoftPLC Parameter 8Read and write
SoftPLC Parameter 9Read and write
SoftPLC Parameter 10Read and write
SoftPLC Parameter 11Read and write
SoftPLC Parameter 12Read and write
SoftPLC Parameter 13Read and write
SoftPLC Parameter 14Read and write
SoftPLC Parameter 15Read and write
SoftPLC Parameter 16Read and write
SoftPLC Parameter 17Read and write
SoftPLC Parameter 18Read and write
SoftPLC Parameter 19Read and write
SoftPLC Parameter 20Read and write
SoftPLC Parameter 21Read and write
SoftPLC Parameter 22Read and write
SoftPLC Parameter 23Read and write
SoftPLC Parameter 24Read and write
SoftPLC Parameter 25Read and write
SoftPLC Parameter 26Read and write
SoftPLC Parameter 27Read and write
SoftPLC Parameter 28Read and write
SoftPLC Parameter 29Read and write
SoftPLC Parameter 30Read and write
SoftPLC Parameter 31Read and write
SoftPLC Parameter 32Read and write
SoftPLC Parameter 33Read and write
SoftPLC Parameter 34Read and write
SoftPLC Parameter 35Read and write
SoftPLC Parameter 36Read and write
SoftPLC Parameter 37Read and write
SoftPLC Parameter 38Read and write
SoftPLC Parameter 39Read and write
SoftPLC Parameter 40Read and write
SoftPLC Parameter 41Read and write
SoftPLC Parameter 42Read and write
SoftPLC Parameter 43Read and write
SoftPLC Parameter 44Read and write
SoftPLC Parameter 45Read and write
SoftPLC Parameter 46Read and write
SoftPLC Parameter 47Read and write
SoftPLC Parameter 48Read and write
SoftPLC Parameter 49Read and write
SoftPLC Parameter 50Read and write

Loading registers…

The ModbusCloud Gateway, front at an angle, with the RS485 terminal and the antenna connectors

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Use cases

  • Show motor speed, current, output power and DC link voltage of every drive on one dashboard.
  • Send an alarm when the present fault code is not zero, or when the heatsink temperature passes a threshold.
  • Keep a year of current and power history to see when a pump or fan runs heavier than normal.
  • Change the speed reference or the PID setpoint of a pump from ModbusCloud without going to site.
  • Compare operating hours, enabled time and output energy across drives to plan maintenance.

Installation

  1. Fit the RS485-01 module in the drive and connect terminal 1 (A) and terminal 2 (B) to RS485 A and B of the ModbusCloud Gateway. Switch on termination (S1) on the last device.

  2. On the drive keypad set P0308 to the Modbus address, P0310 to the baud rate, P0311 to the byte format and P0312 to 2 (Modbus RTU).

  3. If ModbusCloud should control the drive, set the command and reference sources in P0220 to P0228 to Serial/USB.

  4. In ModbusCloud add a Modbus device on the Gateway with the same address and serial settings and import this template.

  5. Check that Motor Speed, Motor Current and DC Link Voltage show plausible values with the drive powered.

Things to watch for

The drive does not answer on the bus. What should I check?

Check that the RS485 module is fitted and P0316 shows 1 (active). Address, baud rate and byte format in P0308, P0310 and P0311 must match the settings in ModbusCloud; firmware V6.0X ships with 8 data bits, no parity and 2 stop bits. If it still stays silent, swap A and B and check the termination switch.

Why does Motor Current show ten times the real value?

The drive sends values as whole numbers without the decimal point, so 3.5 A arrives as 35. The template applies the scale from the parameter list. Parameters whose range is a multiple of the rated current, such as the overload currents, are read with scale 1 because their resolution is not stated.

How do I start the motor and set the speed?

Set the command and reference sources (P0220 to P0228) to Serial/USB. Then write the speed reference, where 8192 equals the synchronous motor speed, and write the serial control word with bit 0 (ramp enable), bit 1 (general enable) and bit 4 (remote) set. Test with the motor uncoupled first.

Some parameters refuse a write. Why?

Parameters marked as configuration parameters can only be changed with the motor stopped, and read only parameters never accept a write. Values outside the range in the comment are rejected as well. Change one setting at a time and read it back to confirm it took effect.

Can I connect several CFW11 drives to one Gateway?

Yes. Give each drive its own address in P0308 and use the same baud rate and byte format on all of them. Wire the bus as one line from drive to drive and enable termination only on the two ends.