Acrel Acrel ADL400 Modbus RTU template

Acrel ADL400

Three-phase energy meter that measures power, energy per tariff, demand and harmonics over Modbus RTU.

The Acrel ADL400 is a three-phase multifunction energy meter that measures power, energy per tariff, demand and harmonics on a DIN rail in distribution boards. This Modbus RTU template reads voltages, currents, power, energy, demand and harmonics, and lets you set the CT and PT ratio, clock and communication settings from ModbusCloud.

Protocol
Modbus RTU
Connection
RS485, 9600 baud
Registers
578, read and write
Brand
Acrel
Key readings
Voltage per phase · Current per phase · Active power · Power factor · Frequency · Active energy · Reactive energy · Harmonic distortion
Available commands
CT ratio · PT ratio · Modbus address and baud rate · Clock
Compatible models
ADL400
Last updated

Registers (578)

578 read, 18 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Voltage L1VRead97FC03uint16
Voltage L2VRead98FC03uint16
Voltage L3VRead99FC03uint16
Voltage L1-L2VRead120FC03uint16
Voltage L3-L2VRead121FC03uint16
Voltage L1-L3VRead
Current L1ARead
Current L2ARead
Current L3ARead
Zero Sequence CurrentRead
Active Power L1kWRead
Active Power L2kWRead
Active Power L3kWRead
Total Active PowerkWRead
Reactive Power L1kvarRead
Reactive Power L2kvarRead
Reactive Power L3kvarRead
Total Reactive PowerkvarRead
Apparent Power L1kVARead
Apparent Power L2kVARead
Apparent Power L3kVARead
Total Apparent PowerkVARead
Power Factor L1Read
Power Factor L2Read
Power Factor L3Read
Total Power FactorRead
FrequencyHzRead
Voltage ImbalanceRead
Current ImbalanceRead
Total Active EnergykWhRead
Spike Active EnergykWhRead
Peak Active EnergykWhRead
Flat Active EnergykWhRead
Valley Active EnergykWhRead
Forward Active EnergykWhRead
Forward Active Energy SpikekWhRead
Forward Active Energy PeakkWhRead
Forward Active Energy FlatkWhRead
Forward Active Energy ValleykWhRead
Reverse Active EnergykWhRead
Reverse Active Energy SpikekWhRead
Reverse Active Energy PeakkWhRead
Reverse Active Energy FlatkWhRead
Reverse Active Energy ValleykWhRead
Total Reactive EnergykvarhRead
Spike Reactive EnergykvarhRead
Peak Reactive EnergykvarhRead
Flat Reactive EnergykvarhRead
Valley Reactive EnergykvarhRead
Forward Reactive EnergykvarhRead
Forward Reactive Energy SpikekvarhRead
Forward Reactive Energy PeakkvarhRead
Forward Reactive Energy FlatkvarhRead
Forward Reactive Energy ValleykvarhRead
Reverse Reactive EnergykvarhRead
Reverse Reactive Energy SpikekvarhRead
Reverse Reactive Energy PeakkvarhRead
Reverse Reactive Energy FlatkvarhRead
Reverse Reactive Energy ValleykvarhRead
Forward Active Energy L1Read
Forward Active Energy L2Read
Forward Active Energy L3Read
Forward Active Max DemandkWRead
Forward Active Max Demand Time Minute HourRead
Forward Active Max Demand Time Day MonthRead
Reverse Active Max DemandkWRead
Reverse Active Max Demand Time Minute HourRead
Reverse Active Max Demand Time Day MonthRead
Forward Reactive Max DemandkvarRead
Forward Reactive Max Demand Time Minute HourRead
Forward Reactive Max Demand Time Day MonthRead
Reverse Reactive Max DemandkvarRead
Reverse Reactive Max Demand Time Minute HourRead
Reverse Reactive Max Demand Time Day MonthRead
Forward Active DemandkWRead
Reverse Active DemandkWRead
Forward Reactive DemandkvarRead
Reverse Reactive DemandkvarRead
Active Power L1 High ResolutionkWRead
Active Power L2 High ResolutionkWRead
Active Power L3 High ResolutionkWRead
Total Active Power High ResolutionkWRead
Reactive Power L1 High ResolutionkvarRead
Reactive Power L2 High ResolutionkvarRead
Reactive Power L3 High ResolutionkvarRead
Total Reactive Power High ResolutionkvarRead
Apparent Power L1 High ResolutionkVARead
Apparent Power L2 High ResolutionkVARead
Apparent Power L3 High ResolutionkVARead
Total Apparent Power High ResolutionkVARead
PT RatioRead and write
CT RatioRead and write
Running StateRead and write
Address and Baud RateRead and write
Parity and Stop BitsRead and write
Pulse ConstantRead
CodeRead and write
Backlight TimeminRead and write
Clock Second MinuteRead and write
Clock Hour DayRead and write
Clock Month YearRead and write
Daily Freeze HourRead and write
Monthly Freeze Day HourRead and write
Time Zone Setting 1Read and write
Time Zone Setting 2Read and write
Time Zone Setting 3Read and write
Time Zone Setting 4Read and write
Time Zone Setting 5Read and write
Time Zone Setting 6Read and write
Time List 1 Parameter 1Read
Time List 1 Parameter 2Read
Time List 1 Parameter 3Read
Time List 1 Parameter 4Read
Time List 1 Parameter 5Read
Time List 1 Parameter 6Read
Time List 1 Parameter 7Read
Time List 1 Parameter 8Read
Time List 1 Parameter 9Read
Time List 2 Parameter 1Read
Time List 2 Parameter 2Read
Time List 2 Parameter 3Read
Time List 2 Parameter 4Read
Time List 2 Parameter 5Read
Time List 2 Parameter 6Read
Time List 2 Parameter 7Read
Time List 2 Parameter 8Read
Time List 2 Parameter 9Read
Max Voltage L1Read
Max Voltage L1 DateRead
Max Voltage L1 TimeRead
Max Voltage L2Read
Max Voltage L2 DateRead
Max Voltage L2 TimeRead
Max Voltage L3Read
Max Voltage L3 DateRead
Max Voltage L3 TimeRead
Max Current L1Read
Max Current L1 DateRead
Max Current L1 TimeRead
Max Current L2Read
Max Current L2 DateRead
Max Current L2 TimeRead
Max Current L3Read
Max Current L3 DateRead
Max Current L3 TimeRead
Max Active Power L1Read
Max Active Power L1 DateRead
Max Active Power L1 TimeRead
Max Active Power L2Read
Max Active Power L2 DateRead
Max Active Power L2 TimeRead
Max Active Power L3Read
Max Active Power L3 DateRead
Max Active Power L3 TimeRead
Max Active Power TotalRead
Max Active Power Total DateRead
Max Active Power Total TimeRead
Max Reactive Power L1Read
Max Reactive Power L1 DateRead
Max Reactive Power L1 TimeRead
Max Reactive Power L2Read
Max Reactive Power L2 DateRead
Max Reactive Power L2 TimeRead
Max Reactive Power L3Read
Max Reactive Power L3 DateRead
Max Reactive Power L3 TimeRead
Max Reactive Power TotalRead
Max Reactive Power Total DateRead
Max Reactive Power Total TimeRead
Max Apparent Power L1Read
Max Apparent Power L1 DateRead
Max Apparent Power L1 TimeRead
Max Apparent Power L2Read
Max Apparent Power L2 DateRead
Max Apparent Power L2 TimeRead
Max Apparent Power L3Read
Max Apparent Power L3 DateRead
Max Apparent Power L3 TimeRead
Max Apparent Power TotalRead
Max Apparent Power Total DateRead
Max Apparent Power Total TimeRead
Min Voltage L1Read
Min Voltage L1 DateRead
Min Voltage L1 TimeRead
Min Voltage L2Read
Min Voltage L2 DateRead
Min Voltage L2 TimeRead
Min Voltage L3Read
Min Voltage L3 DateRead
Min Voltage L3 TimeRead
Min Current L1Read
Min Current L1 DateRead
Min Current L1 TimeRead
Min Current L2Read
Min Current L2 DateRead
Min Current L2 TimeRead
Min Current L3Read
Min Current L3 DateRead
Min Current L3 TimeRead
Min Active Power L1Read
Min Active Power L1 DateRead
Min Active Power L1 TimeRead
Min Active Power L2Read
Min Active Power L2 DateRead
Min Active Power L2 TimeRead
Min Active Power L3Read
Min Active Power L3 DateRead
Min Active Power L3 TimeRead
Min Active Power TotalRead
Min Active Power Total DateRead
Min Active Power Total TimeRead
Min Reactive Power L1Read
Min Reactive Power L1 DateRead
Min Reactive Power L1 TimeRead
Min Reactive Power L2Read
Min Reactive Power L2 DateRead
Min Reactive Power L2 TimeRead
Min Reactive Power L3Read
Min Reactive Power L3 DateRead
Min Reactive Power L3 TimeRead
Min Reactive Power TotalRead
Min Reactive Power Total DateRead
Min Reactive Power Total TimeRead
Min Apparent Power L1Read
Min Apparent Power L1 DateRead
Min Apparent Power L1 TimeRead
Min Apparent Power L2Read
Min Apparent Power L2 DateRead
Min Apparent Power L2 TimeRead
Min Apparent Power TotalRead
Min Apparent Power Total DateRead
Min Apparent Power Total TimeRead
Voltage L1 Float SecondaryVRead
Voltage L2 Float SecondaryVRead
Voltage L3 Float SecondaryVRead
Voltage L1-L2 Float SecondaryVRead
Voltage L3-L2 Float SecondaryVRead
Voltage L1-L3 Float SecondaryVRead
Current L1 Float SecondaryARead
Current L2 Float SecondaryARead
Current L3 Float SecondaryARead
Active Power L1 Float SecondaryRead
Active Power L2 Float SecondaryRead
Active Power L3 Float SecondaryRead
Total Active Power Float SecondaryRead
Reactive Power L1 Float SecondaryRead
Reactive Power L2 Float SecondaryRead
Reactive Power L3 Float SecondaryRead
Total Reactive Power Float SecondaryRead
Apparent Power L1 Float SecondaryRead
Apparent Power L2 Float SecondaryRead
Apparent Power L3 Float SecondaryRead
Total Apparent Power Float SecondaryRead
Power Factor L1 Float SecondaryRead
Power Factor L2 Float SecondaryRead
Power Factor L3 Float SecondaryRead
Total Power Factor Float SecondaryRead
Frequency Float SecondaryHzRead
Neutral Current Float SecondaryARead
Voltage L1 Float PrimaryVRead
Voltage L2 Float PrimaryVRead
Voltage L3 Float PrimaryVRead
Voltage L1-L2 Float PrimaryVRead
Voltage L3-L2 Float PrimaryVRead
Voltage L1-L3 Float PrimaryVRead
Current L1 Float PrimaryARead
Current L2 Float PrimaryARead
Current L3 Float PrimaryARead
Neutral Current Float PrimaryARead
Active Power L1 Float PrimaryRead
Active Power L2 Float PrimaryRead
Active Power L3 Float PrimaryRead
Total Active Power Float PrimaryRead
Reactive Power L1 Float PrimaryRead
Reactive Power L2 Float PrimaryRead
Reactive Power L3 Float PrimaryRead
Total Reactive Power Float PrimaryRead
Apparent Power L1 Float PrimaryRead
Apparent Power L2 Float PrimaryRead
Apparent Power L3 Float PrimaryRead
Total Apparent Power Float PrimaryRead
Power Factor L1 Float PrimaryRead
Power Factor L2 Float PrimaryRead
Power Factor L3 Float PrimaryRead
Total Power Factor Float PrimaryRead
Frequency Float PrimaryHzRead
Voltage Imbalance Float PrimaryRead
Current Imbalance Float PrimaryRead
Forward Active Demand Float PrimaryRead
Reverse Active Demand Float PrimaryRead
Forward Reactive Demand Float PrimaryRead
Reverse Reactive Demand Float PrimaryRead
Total Active Energy PrimarykWhRead
Spike Active Energy PrimarykWhRead
Peak Active Energy PrimarykWhRead
Flat Active Energy PrimarykWhRead
Valley Active Energy PrimarykWhRead
Forward Active Energy PrimarykWhRead
Forward Active Energy Spike PrimarykWhRead
Forward Active Energy Peak PrimarykWhRead
Forward Active Energy Flat PrimarykWhRead
Forward Active Energy Valley PrimarykWhRead
Reverse Active Energy PrimarykWhRead
Reverse Active Energy Spike PrimarykWhRead
Reverse Active Energy Peak PrimarykWhRead
Reverse Active Energy Flat PrimarykWhRead
Reverse Active Energy Valley PrimarykWhRead
Total Reactive Energy PrimarykvarhRead
Spike Reactive Energy PrimarykvarhRead
Peak Reactive Energy PrimarykvarhRead
Flat Reactive Energy PrimarykvarhRead
Valley Reactive Energy PrimarykvarhRead
Forward Reactive Energy PrimarykvarhRead
Forward Reactive Energy Spike PrimarykvarhRead
Forward Reactive Energy Peak PrimarykvarhRead
Forward Reactive Energy Flat PrimarykvarhRead
Forward Reactive Energy Valley PrimarykvarhRead
Reverse Reactive Energy PrimarykvarhRead
Reverse Reactive Energy Spike PrimarykvarhRead
Reverse Reactive Energy Peak PrimarykvarhRead
Reverse Reactive Energy Flat PrimarykvarhRead
Reverse Reactive Energy Valley PrimarykvarhRead
THD Voltage L1Read
THD Voltage L2Read
THD Voltage L3Read
THD Current L1Read
THD Current L2Read
THD Current L3Read
Harmonic 2 Voltage L1Read
Harmonic 3 Voltage L1Read
Harmonic 4 Voltage L1Read
Harmonic 5 Voltage L1Read
Harmonic 6 Voltage L1Read
Harmonic 7 Voltage L1Read
Harmonic 8 Voltage L1Read
Harmonic 9 Voltage L1Read
Harmonic 10 Voltage L1Read
Harmonic 11 Voltage L1Read
Harmonic 12 Voltage L1Read
Harmonic 13 Voltage L1Read
Harmonic 14 Voltage L1Read
Harmonic 15 Voltage L1Read
Harmonic 16 Voltage L1Read
Harmonic 17 Voltage L1Read
Harmonic 18 Voltage L1Read
Harmonic 19 Voltage L1Read
Harmonic 20 Voltage L1Read
Harmonic 21 Voltage L1Read
Harmonic 22 Voltage L1Read
Harmonic 23 Voltage L1Read
Harmonic 24 Voltage L1Read
Harmonic 25 Voltage L1Read
Harmonic 26 Voltage L1Read
Harmonic 27 Voltage L1Read
Harmonic 28 Voltage L1Read
Harmonic 29 Voltage L1Read
Harmonic 30 Voltage L1Read
Harmonic 31 Voltage L1Read
Harmonic 2 Voltage L2Read
Harmonic 3 Voltage L2Read
Harmonic 4 Voltage L2Read
Harmonic 5 Voltage L2Read
Harmonic 6 Voltage L2Read
Harmonic 7 Voltage L2Read
Harmonic 8 Voltage L2Read
Harmonic 9 Voltage L2Read
Harmonic 10 Voltage L2Read
Harmonic 11 Voltage L2Read
Harmonic 12 Voltage L2Read
Harmonic 13 Voltage L2Read
Harmonic 14 Voltage L2Read
Harmonic 15 Voltage L2Read
Harmonic 16 Voltage L2Read
Harmonic 17 Voltage L2Read
Harmonic 18 Voltage L2Read
Harmonic 19 Voltage L2Read
Harmonic 20 Voltage L2Read
Harmonic 21 Voltage L2Read
Harmonic 22 Voltage L2Read
Harmonic 23 Voltage L2Read
Harmonic 24 Voltage L2Read
Harmonic 25 Voltage L2Read
Harmonic 26 Voltage L2Read
Harmonic 27 Voltage L2Read
Harmonic 28 Voltage L2Read
Harmonic 29 Voltage L2Read
Harmonic 30 Voltage L2Read
Harmonic 31 Voltage L2Read
Harmonic 2 Voltage L3Read
Harmonic 3 Voltage L3Read
Harmonic 4 Voltage L3Read
Harmonic 5 Voltage L3Read
Harmonic 6 Voltage L3Read
Harmonic 7 Voltage L3Read
Harmonic 8 Voltage L3Read
Harmonic 9 Voltage L3Read
Harmonic 10 Voltage L3Read
Harmonic 11 Voltage L3Read
Harmonic 12 Voltage L3Read
Harmonic 13 Voltage L3Read
Harmonic 14 Voltage L3Read
Harmonic 15 Voltage L3Read
Harmonic 16 Voltage L3Read
Harmonic 17 Voltage L3Read
Harmonic 18 Voltage L3Read
Harmonic 19 Voltage L3Read
Harmonic 20 Voltage L3Read
Harmonic 21 Voltage L3Read
Harmonic 22 Voltage L3Read
Harmonic 23 Voltage L3Read
Harmonic 24 Voltage L3Read
Harmonic 25 Voltage L3Read
Harmonic 26 Voltage L3Read
Harmonic 27 Voltage L3Read
Harmonic 28 Voltage L3Read
Harmonic 29 Voltage L3Read
Harmonic 30 Voltage L3Read
Harmonic 31 Voltage L3Read
Harmonic 2 Current L1Read
Harmonic 3 Current L1Read
Harmonic 4 Current L1Read
Harmonic 5 Current L1Read
Harmonic 6 Current L1Read
Harmonic 7 Current L1Read
Harmonic 8 Current L1Read
Harmonic 9 Current L1Read
Harmonic 10 Current L1Read
Harmonic 11 Current L1Read
Harmonic 12 Current L1Read
Harmonic 13 Current L1Read
Harmonic 14 Current L1Read
Harmonic 15 Current L1Read
Harmonic 16 Current L1Read
Harmonic 17 Current L1Read
Harmonic 18 Current L1Read
Harmonic 19 Current L1Read
Harmonic 20 Current L1Read
Harmonic 21 Current L1Read
Harmonic 22 Current L1Read
Harmonic 23 Current L1Read
Harmonic 24 Current L1Read
Harmonic 25 Current L1Read
Harmonic 26 Current L1Read
Harmonic 27 Current L1Read
Harmonic 28 Current L1Read
Harmonic 29 Current L1Read
Harmonic 30 Current L1Read
Harmonic 31 Current L1Read
Harmonic 2 Current L2Read
Harmonic 3 Current L2Read
Harmonic 4 Current L2Read
Harmonic 5 Current L2Read
Harmonic 6 Current L2Read
Harmonic 7 Current L2Read
Harmonic 8 Current L2Read
Harmonic 9 Current L2Read
Harmonic 10 Current L2Read
Harmonic 11 Current L2Read
Harmonic 12 Current L2Read
Harmonic 13 Current L2Read
Harmonic 14 Current L2Read
Harmonic 15 Current L2Read
Harmonic 16 Current L2Read
Harmonic 17 Current L2Read
Harmonic 18 Current L2Read
Harmonic 19 Current L2Read
Harmonic 20 Current L2Read
Harmonic 21 Current L2Read
Harmonic 22 Current L2Read
Harmonic 23 Current L2Read
Harmonic 24 Current L2Read
Harmonic 25 Current L2Read
Harmonic 26 Current L2Read
Harmonic 27 Current L2Read
Harmonic 28 Current L2Read
Harmonic 29 Current L2Read
Harmonic 30 Current L2Read
Harmonic 31 Current L2Read
Harmonic 2 Current L3Read
Harmonic 3 Current L3Read
Harmonic 4 Current L3Read
Harmonic 5 Current L3Read
Harmonic 6 Current L3Read
Harmonic 7 Current L3Read
Harmonic 8 Current L3Read
Harmonic 9 Current L3Read
Harmonic 10 Current L3Read
Harmonic 11 Current L3Read
Harmonic 12 Current L3Read
Harmonic 13 Current L3Read
Harmonic 14 Current L3Read
Harmonic 15 Current L3Read
Harmonic 16 Current L3Read
Harmonic 17 Current L3Read
Harmonic 18 Current L3Read
Harmonic 19 Current L3Read
Harmonic 20 Current L3Read
Harmonic 21 Current L3Read
Harmonic 22 Current L3Read
Harmonic 23 Current L3Read
Harmonic 24 Current L3Read
Harmonic 25 Current L3Read
Harmonic 26 Current L3Read
Harmonic 27 Current L3Read
Harmonic 28 Current L3Read
Harmonic 29 Current L3Read
Harmonic 30 Current L3Read
Harmonic 31 Current L3Read
Fundamental Voltage L1VRead
Fundamental Voltage L2VRead
Fundamental Voltage L3VRead
Harmonic Voltage L1VRead
Harmonic Voltage L2VRead
Harmonic Voltage L3VRead
Fundamental Current L1ARead
Fundamental Current L2ARead
Fundamental Current L3ARead
Harmonic Current L1ARead
Harmonic Current L2ARead
Harmonic Current L3ARead
Fundamental Active Power L1Read
Fundamental Active Power L2Read
Fundamental Active Power L3Read
Total Fundamental Active PowerRead
Fundamental Reactive Power L1Read
Fundamental Reactive Power L2Read
Fundamental Reactive Power L3Read
Total Fundamental Reactive PowerRead
Harmonic Active Power L1Read
Harmonic Active Power L2Read
Harmonic Active Power L3Read
Total Harmonic Active PowerRead
Harmonic Reactive Power L1Read
Harmonic Reactive Power L2Read
Harmonic Reactive Power L3Read
Total Harmonic Reactive PowerRead
Last Month Freeze Time Year MonthRead
Last Month Freeze Time Day HourRead
Last Month Total Active EnergyRead
Last Month Spike Active EnergyRead
Last Month Peak Active EnergyRead
Last Month Flat Active EnergyRead
Last Month Valley Active EnergyRead
Last Month Total Reactive EnergyRead
Last Month Spike Reactive EnergyRead
Last Month Peak Reactive EnergyRead
Last Month Flat Reactive EnergyRead
Last Month Valley Reactive EnergyRead
Last Month Forward Active Energy L1Read
Last Month Forward Active Energy L2Read
Last Month Forward Active Energy L3Read
Last Month Max Active DemandRead
Last Month Max Active Demand Time Minute HourRead
Last Month Max Active Demand Time Day MonthRead
Last Month Max Reactive DemandRead
Last Month Max Reactive Demand Time Minute HourRead
Last Month Max Reactive Demand Time Day MonthRead
Last Day Freeze Time Year MonthRead
Last Day Freeze Time Day HourRead
Last Day Total Active EnergyRead
Last Day Spike Active EnergyRead
Last Day Peak Active EnergyRead
Last Day Flat Active EnergyRead
Last Day Valley Active EnergyRead
Last Day Total Reactive EnergyRead
Last Day Spike Reactive EnergyRead
Last Day Peak Reactive EnergyRead
Last Day Flat Reactive EnergyRead
Last Day Valley Reactive EnergyRead
Last Day Forward Active Energy L1Read
Last Day Forward Active Energy L2Read
Last Day Forward Active Energy L3Read
Last Day Max Active DemandRead
Last Day Max Active Demand Time Minute HourRead
Last Day Max Active Demand Time Day MonthRead
Last Day Max Reactive DemandRead
Last Day Max Reactive Demand Time Minute HourRead
Last Day Max Reactive Demand Time Day MonthRead

Loading registers…

The ModbusCloud Gateway, front at an angle, with the RS485 terminal and the antenna connectors

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Use cases

  • Show voltage, current and power per phase of a distribution board in one dashboard.
  • Set an alarm when the total power factor drops below a threshold you choose.
  • Compare daily and monthly energy per tariff from the 365 days of history.
  • Watch the voltage and current harmonic distortion of a group with many drives or inverters.
  • Track forward and reverse energy separately on a PV installation.
  • Correct the CT ratio remotely after a transformer change.

Installation

  1. Connect terminals A and B of the meter to the RS485 port of the ModbusCloud Gateway with a shielded twisted pair, and terminate both ends of the bus.

  2. In the meter menu set a unique address, the baud rate and the parity, for example 9600 baud and no parity.

  3. Set the CT and PT ratio in the meter when it measures through transformers.

  4. In ModbusCloud, add a Modbus device with the same address and settings and import this template.

  5. Check that the phase voltages and the total active energy come in.

Things to watch for

The meter does not respond. What should I check?

Check that address, baud rate and parity in ModbusCloud match the meter menu. The default parity is none. Swap A and B if nothing answers, and check the termination at both ends of the bus.

Why is the energy value far too low?

The energy counters at the start of the map give the secondary value. With current or voltage transformers, multiply by the CT and PT ratio, or read the primary side energy registers, which already include them.

Some history or event values return errors.

The meter keeps its history in blocks that it expects to be read as a whole. If single history values return errors, read only the live values and use the ModbusCloud history instead.

What should I watch out for when writing settings?

A new address, baud rate or parity takes effect at once, so change the settings in ModbusCloud right after. A wrong CT or PT ratio changes every energy and power value. Read the register first and only write values within the range the meter allows.

Want to see how it works?

Electrician working in an open distribution board