FoxESS FoxESS H3 Modbus RTU template

FoxESS H3

Three-phase hybrid inverter with PV, battery and grid values per phase, work mode and remote power control.

The FoxESS H3 is a three-phase hybrid inverter that combines two PV inputs, a battery and the grid, with a backup output for homes and small businesses. This Modbus RTU template reads PV, grid, load and battery values, energy counters and fault codes, and lets you set the work mode, SOC limits and remote active power from ModbusCloud.

Protocol
Modbus RTU
Connection
RS485, 9600 baud
Registers
76, read and write
Brand
FoxESS
Key readings
PV power · Grid power per phase · Load power · Battery SOC · Battery power · Solar generation · Feed-in and grid consumption · Fault codes
Available commands
Work mode · Minimum and maximum SOC · Battery charge current · Remote active power
Compatible models
H3 · FoxESS H3-6.0-E · FoxESS H3-8.0-E · FoxESS H3-10.0-E · FoxESS H3-12.0-E
Last updated

Registers (76)

76 read, 9 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Master Firmware VersionRead
Slave Firmware VersionRead
Manager Firmware VersionRead
PV1 VoltageVRead
PV1 CurrentARead
PV1 PowerkWRead
PV2 VoltageVRead
PV2 CurrentARead
PV2 PowerkWRead
Grid Voltage RVRead
Grid Voltage SVRead
Grid Voltage TVRead
Inverter Current RARead
Inverter Current SARead
Inverter Current TARead
Inverter Power RkWRead
Inverter Power SkWRead
Inverter Power TkWRead
EPS Power RkWRead
EPS Power SkWRead
EPS Power TkWRead
Grid CT Power RkWRead
Grid CT Power SkWRead
Grid CT Power TkWRead
Load Power RkWRead
Load Power SkWRead
Load Power TkWRead
Inverter Battery PowerkWRead
Grid FrequencyHzRead
EPS FrequencyHzRead
Inverter Temp°CRead
Ambient Temp°CRead
Inverter Fault Code 1Read
Inverter Fault Code 2Read
Inverter Fault Code 4Read
Inverter Fault Code 5Read
Inverter Fault Code 6Read
Inverter Fault Code 7Read
Inverter Fault Code 8Read
Inverter State CodeRead
Solar Generation TotalkWhRead
Solar Generation TodaykWhRead
Battery Charge TotalkWhRead
Battery Charge TodaykWhRead
Battery Discharge TotalkWhRead
Battery Discharge TodaykWhRead
Feed-in TotalkWhRead
Feed-in TodaykWhRead
Grid Consumption TotalkWhRead
Grid Consumption TodaykWhRead
Yield TotalkWhRead
Yield TodaykWhRead
Input Energy TotalkWhRead
Input Energy TodaykWhRead
Load Energy TotalkWhRead
Load Energy TodaykWhRead
Battery VoltageVRead
Battery CurrentARead
Battery SoC%Read
Battery SoH%Read
Battery Temp°CRead
BMS Cell Temp High°CRead
BMS Cell Temp Low°CRead
BMS Cell mV HighmVRead
BMS Cell mV LowmVRead
BMS kWh RemainingkWhRead
Work ModeRead and write
Max Charge CurrentARead and write
Max Discharge CurrentARead and write
Min SoC%Read and write
Max SoC%Read and write
Min SoC (On Grid)%Read and write
Inverter ModelRead
Remote Control EnableRead and write
Remote Control TimeoutsRead and write
Remote Active PowerWRead and write

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Show PV power, battery SOC and grid power per phase of a FoxESS H3 on a dashboard.
  • Get an alert when a fault code register is no longer 0 or the battery SOC drops below a threshold.
  • Compare solar generation, feed-in, grid consumption and battery throughput per day in the history.
  • Raise the minimum SOC remotely before an expected grid outage so the EPS output has reserve.
  • Switch the work mode between Self Use, Feed-in First and Back-up from ModbusCloud.

Installation

  1. Connect the RS485 pair from the communication port of the inverter to the RS485 port of the ModbusCloud Gateway, A to A and B to B, with 120 ohm at the end of the bus.

  2. Check the Modbus address in the inverter settings; the default is 247.

  3. In ModbusCloud, add a Modbus device with protocol RTU, address 247, 9600 baud and 8N1, and import this template.

  4. Check that Inverter Model shows H3 and Battery SoC matches the display.

Things to watch for

The inverter does not answer. What should I check?

Check that ModbusCloud uses address 247 and 9600 baud, swap A and B if nothing comes back and terminate the line with 120 ohm. A data logger on the same RS485 port can block the bus.

The BMS cell values and SoH stay empty. Why?

These registers are only filled from master firmware 1.80. Read Master Firmware Version; below 180 the inverter does not provide them.

How do I read feed-in and grid consumption per phase?

Grid CT Power per phase is one signed value: positive is feed-in, negative is power taken from the grid. Use a threshold on the sign for alerts.

Can I change the work mode and SOC limits from ModbusCloud?

Yes, work mode, SOC limits, charge and discharge current and the remote control registers are writable. Writing is off per gateway by default; request it for the gateway in the portal. Remote control needs Remote Control Enable and a timeout, after which the inverter returns to its work mode.