Hoval TopTronic E Measuring Module

Hoval module for up to 16 M-Bus meters with energy, power, flow, volume and temperatures over Modbus TCP.

The Hoval TopTronic E Measuring Module is a controller module that reads up to 16 meters over M-Bus in Hoval TopTronic E systems, for example in boiler plants and greenhouses. This Modbus TCP template reads energy, power, flow, volume and temperatures of every meter through the Hoval Modbus gateway into ModbusCloud.

Protocol
Modbus TCP
Connection
Ethernet, Modbus TCP
Registers
221, read only
Brand
Hoval
Key readings
Energy · Power · Flow rate · Volume · Flow and return temperature · Temperature difference · Current, voltage and cos phi · Meter serial number
Compatible models
TopTronic E measuring module (MWA)
Last updated

Registers (221)

221 read, 0 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
M-Bus Meter 1 EnergyMWhRead
M-Bus Meter 1 PowerkWRead
M-Bus Meter 1 Flow Ratel/hRead
M-Bus Meter 1 Volumem³Read
M-Bus Meter 1 Flow Temperature°CRead
M-Bus Meter 1 Return Temperature°CRead
M-Bus Meter 1 Temperature DifferenceKRead
M-Bus Meter 1 CurrentARead
M-Bus Meter 1 VoltageVRead
M-Bus Meter 1 Cos PhiRead
M-Bus Meter 1 Serial NumberRead
M-Bus Meter 2 EnergyMWhRead
M-Bus Meter 2 PowerkWRead
M-Bus Meter 2 Flow Ratel/hRead
M-Bus Meter 2 Volumem³Read
M-Bus Meter 2 Flow Temperature°CRead
M-Bus Meter 2 Return Temperature°CRead
M-Bus Meter 2 Temperature DifferenceKRead
M-Bus Meter 2 CurrentARead
M-Bus Meter 2 VoltageVRead
M-Bus Meter 2 Cos PhiRead
M-Bus Meter 2 Serial NumberRead
M-Bus Meter 3 EnergyMWhRead
M-Bus Meter 3 PowerkWRead
M-Bus Meter 3 Flow Ratel/hRead
M-Bus Meter 3 Volumem³Read
M-Bus Meter 3 Flow Temperature°CRead
M-Bus Meter 3 Return Temperature°CRead
M-Bus Meter 3 Temperature DifferenceKRead
M-Bus Meter 3 CurrentARead
M-Bus Meter 3 VoltageVRead
M-Bus Meter 3 Cos PhiRead
M-Bus Meter 3 Serial NumberRead
M-Bus Meter 4 EnergyMWhRead
M-Bus Meter 4 PowerkWRead
M-Bus Meter 4 Flow Ratel/hRead
M-Bus Meter 4 Volumem³Read
M-Bus Meter 4 Flow Temperature°CRead
M-Bus Meter 4 Return Temperature°CRead
M-Bus Meter 4 Temperature DifferenceKRead
M-Bus Meter 4 CurrentARead
M-Bus Meter 4 VoltageVRead
M-Bus Meter 4 Cos PhiRead
M-Bus Meter 4 Serial NumberRead
M-Bus Meter 5 EnergyMWhRead
M-Bus Meter 5 PowerkWRead
M-Bus Meter 5 Flow Ratel/hRead
M-Bus Meter 5 Volumem³Read
M-Bus Meter 5 Flow Temperature°CRead
M-Bus Meter 5 Return Temperature°CRead
M-Bus Meter 5 Temperature DifferenceKRead
M-Bus Meter 5 CurrentARead
M-Bus Meter 5 VoltageVRead
M-Bus Meter 5 Cos PhiRead
M-Bus Meter 5 Serial NumberRead
M-Bus Meter 6 EnergyMWhRead
M-Bus Meter 6 PowerkWRead
M-Bus Meter 6 Flow Ratel/hRead
M-Bus Meter 6 Volumem³Read
M-Bus Meter 6 Flow Temperature°CRead
M-Bus Meter 6 Return Temperature°CRead
M-Bus Meter 6 Temperature DifferenceKRead
M-Bus Meter 6 CurrentARead
M-Bus Meter 6 VoltageVRead
M-Bus Meter 6 Cos PhiRead
M-Bus Meter 6 Serial NumberRead
M-Bus Meter 7 EnergyMWhRead
M-Bus Meter 7 PowerkWRead
M-Bus Meter 7 Flow Ratel/hRead
M-Bus Meter 7 Volumem³Read
M-Bus Meter 7 Flow Temperature°CRead
M-Bus Meter 7 Return Temperature°CRead
M-Bus Meter 7 Temperature DifferenceKRead
M-Bus Meter 7 CurrentARead
M-Bus Meter 7 VoltageVRead
M-Bus Meter 7 Cos PhiRead
M-Bus Meter 7 Serial NumberRead
M-Bus Meter 8 EnergyMWhRead
M-Bus Meter 8 PowerkWRead
M-Bus Meter 8 Flow Ratel/hRead
M-Bus Meter 8 Volumem³Read
M-Bus Meter 8 Flow Temperature°CRead
M-Bus Meter 8 Return Temperature°CRead
M-Bus Meter 8 Temperature DifferenceKRead
M-Bus Meter 8 CurrentARead
M-Bus Meter 8 VoltageVRead
M-Bus Meter 8 Cos PhiRead
M-Bus Meter 8 Serial NumberRead
M-Bus Meter 9 EnergyMWhRead
M-Bus Meter 9 PowerkWRead
M-Bus Meter 9 Flow Ratel/hRead
M-Bus Meter 9 Volumem³Read
M-Bus Meter 9 Flow Temperature°CRead
M-Bus Meter 9 Return Temperature°CRead
M-Bus Meter 9 Temperature DifferenceKRead
M-Bus Meter 9 CurrentARead
M-Bus Meter 9 VoltageVRead
M-Bus Meter 9 Cos PhiRead
M-Bus Meter 9 Serial NumberRead
M-Bus Meter 10 EnergyMWhRead
M-Bus Meter 10 PowerkWRead
M-Bus Meter 10 Flow Ratel/hRead
M-Bus Meter 10 Volumem³Read
M-Bus Meter 10 Flow Temperature°CRead
M-Bus Meter 10 Return Temperature°CRead
M-Bus Meter 10 Temperature DifferenceKRead
M-Bus Meter 10 CurrentARead
M-Bus Meter 10 VoltageVRead
M-Bus Meter 10 Cos PhiRead
M-Bus Meter 10 Serial NumberRead
M-Bus Meter 11 EnergyMWhRead
M-Bus Meter 11 PowerkWRead
M-Bus Meter 11 Flow Ratel/hRead
M-Bus Meter 11 Volumem³Read
M-Bus Meter 11 Flow Temperature°CRead
M-Bus Meter 11 Return Temperature°CRead
M-Bus Meter 11 Temperature DifferenceKRead
M-Bus Meter 11 CurrentARead
M-Bus Meter 11 VoltageVRead
M-Bus Meter 11 Cos PhiRead
M-Bus Meter 11 Serial NumberRead
M-Bus Meter 12 EnergyMWhRead
M-Bus Meter 12 PowerkWRead
M-Bus Meter 12 Flow Ratel/hRead
M-Bus Meter 12 Volumem³Read
M-Bus Meter 12 Flow Temperature°CRead
M-Bus Meter 12 Return Temperature°CRead
M-Bus Meter 12 Temperature DifferenceKRead
M-Bus Meter 12 CurrentARead
M-Bus Meter 12 VoltageVRead
M-Bus Meter 12 Cos PhiRead
M-Bus Meter 12 Serial NumberRead
M-Bus Meter 13 EnergyMWhRead
M-Bus Meter 13 PowerkWRead
M-Bus Meter 13 Flow Ratel/hRead
M-Bus Meter 13 Volumem³Read
M-Bus Meter 13 Flow Temperature°CRead
M-Bus Meter 13 Return Temperature°CRead
M-Bus Meter 13 Temperature DifferenceKRead
M-Bus Meter 13 CurrentARead
M-Bus Meter 13 VoltageVRead
M-Bus Meter 13 Cos PhiRead
M-Bus Meter 13 Serial NumberRead
M-Bus Meter 14 EnergyMWhRead
M-Bus Meter 14 PowerkWRead
M-Bus Meter 14 Flow Ratel/hRead
M-Bus Meter 14 Volumem³Read
M-Bus Meter 14 Flow Temperature°CRead
M-Bus Meter 14 Return Temperature°CRead
M-Bus Meter 14 Temperature DifferenceKRead
M-Bus Meter 14 CurrentARead
M-Bus Meter 14 VoltageVRead
M-Bus Meter 14 Cos PhiRead
M-Bus Meter 14 Serial NumberRead
M-Bus Meter 15 EnergyMWhRead
M-Bus Meter 15 PowerkWRead
M-Bus Meter 15 Flow Ratel/hRead
M-Bus Meter 15 Volumem³Read
M-Bus Meter 15 Flow Temperature°CRead
M-Bus Meter 15 Return Temperature°CRead
M-Bus Meter 15 Temperature DifferenceKRead
M-Bus Meter 15 CurrentARead
M-Bus Meter 15 VoltageVRead
M-Bus Meter 15 Cos PhiRead
M-Bus Meter 15 Serial NumberRead
M-Bus Meter 16 EnergyMWhRead
M-Bus Meter 16 PowerkWRead
M-Bus Meter 16 Flow Ratel/hRead
M-Bus Meter 16 Volumem³Read
M-Bus Meter 16 Flow Temperature°CRead
M-Bus Meter 16 Return Temperature°CRead
M-Bus Meter 16 Temperature DifferenceKRead
M-Bus Meter 16 CurrentARead
M-Bus Meter 16 VoltageVRead
M-Bus Meter 16 Cos PhiRead
M-Bus Meter 16 Serial NumberRead
Active Error 1 Appearance TimeRead
Active Error 1 Appearance DateRead
Active Error 1 Disappear TimeRead
Active Error 1 Disappear DateRead
Active Error 1 SourceRead
Active Error 1 Function GroupRead
Active Error 1 Function NumberRead
Active Error 1 Error TypeRead
Active Error 1 Error CodeRead
Active Error 2 Appearance TimeRead
Active Error 2 Appearance DateRead
Active Error 2 Disappear TimeRead
Active Error 2 Disappear DateRead
Active Error 2 SourceRead
Active Error 2 Function GroupRead
Active Error 2 Function NumberRead
Active Error 2 Error TypeRead
Active Error 2 Error CodeRead
Active Error 3 Appearance TimeRead
Active Error 3 Appearance DateRead
Active Error 3 Disappear TimeRead
Active Error 3 Disappear DateRead
Active Error 3 SourceRead
Active Error 3 Function GroupRead
Active Error 3 Function NumberRead
Active Error 3 Error TypeRead
Active Error 3 Error CodeRead
Active Error 4 Appearance TimeRead
Active Error 4 Appearance DateRead
Active Error 4 Disappear TimeRead
Active Error 4 Disappear DateRead
Active Error 4 SourceRead
Active Error 4 Function GroupRead
Active Error 4 Function NumberRead
Active Error 4 Error TypeRead
Active Error 4 Error CodeRead
Active Error 5 Appearance TimeRead
Active Error 5 Appearance DateRead
Active Error 5 Disappear TimeRead
Active Error 5 Disappear DateRead
Active Error 5 SourceRead
Active Error 5 Function GroupRead
Active Error 5 Function NumberRead
Active Error 5 Error TypeRead
Active Error 5 Error CodeRead

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Collect the meter readings of a boiler house or of greenhouse sections in one dashboard and compare energy per meter.
  • Track energy and volume over 365 days and download them as CSV for an energy report or an invoice check.
  • Get an alert when the power or the temperature difference of a meter crosses a threshold.
  • Share a PDF report with the energy readings of each meter with the building owner.

Installation

  1. Connect the Hoval Modbus gateway of the TopTronic E system to the same network as the ModbusCloud Gateway and give it a fixed IP address.

  2. Check the address of the measuring module on its DIP switch or on the TopTronic E operating module. This template is for module address 1.

  3. In ModbusCloud, add a Modbus device with Modbus TCP, the IP address of the Hoval gateway, port 502 and unit ID 1, then import this template.

  4. Check that M-Bus Meter 1 Energy and M-Bus Meter 1 Serial Number match the display and type plate of the first meter.

Things to watch for

The Hoval gateway does not answer. What should I check?

Check that the ModbusCloud Gateway reaches the IP address of the Hoval Modbus gateway, and use port 502 and unit ID 1. The Hoval gateway has to be registered in the HovalConnect app. Meter positions without a meter can time out.

Which meter is M-Bus Meter 1?

M-Bus Meter 1 to 16 are the meter positions of the measuring module. Compare the Serial Number register of each position with the serial number on the type plate of the meter to see which meter sits where.

How do I read a second measuring module?

Every module has its own address on the TopTronic E bus. In the Hoval Modbus data point list the module with address n is MWA UnitId 384 plus n, with its own register addresses. This template is for UnitId 385. Make your own template in ModbusCloud with the addresses Hoval lists for your UnitId.

In which units do the meter values arrive?

Energy comes in MWh with three decimals, a resolution of 1 kWh. Power comes in kW and volume in m³, each with one decimal, and the flow rate in l/h. Compare one reading with the meter display before you use the values for billing.

Want to see how it works?