Windhager Windhager Best Heating Technology Heatpump Modbus TCP template

Windhager Best Heating Technology Heatpump

Monitors and controls Windhager heat pump systems via Modbus TCP

This template connects Windhager heat pump and heating systems via Modbus TCP. It reads temperatures, operating hours, energy data, and alarm codes. It also allows control of heating circuit modes, DHW modes, setpoints, SG Ready status, and party timers.

Protocol
Modbus TCP
Connection
Ethernet, Modbus TCP
Registers
45, read and write
Key readings
Flow and accumulator tank temperatures · Outside and room temperatures · DHW temperature and setpoint · Current heat pump output · Operating hours and energy quantities · Alarm code heat generator
Available commands
Select mode (heating circuits, DHW, buffer) · Eco/Party setpoints and timers · SG Ready status · External heat demand
Compatible models
LOGWIN2 · DOUWIN2 · AEROWIN DELUXE · LogWIN2 DELUXE · LogWIN2 EDEL
Last updated

Registers (45)

44 read, 13 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Flow temperature AW°CRead
Flow temperature setpoint AW°CRead
Current heat pump output%Read
Accumulator tank temperature TPO°CRead
Accumulator tank temperature TPM°CRead
Accumulator tank temperature TPU°CRead
Outside temperature°CRead
Flow temperature heating circuit 1°CRead
Flow temperature setpoint heating circuit 1°CRead
Select mode heating circuit 1Read and write
Optimisation heating circuit 1KRead and write
DHW temperature°CRead
DHW temperature setpoint°CRead
Flow temperature heating circuit 2°CRead
Flow temperature setpoint heating circuit 2°CRead
Room temperature heating circuit 1°CRead
Room temperature heating circuit 2°CRead
Select mode heating circuit 2Read and write
Select mode DHWRead and write
DHW single chargeRead and write
Optimisation heating circuit 2KRead and write
Operating hours coolinghRead
Alarm code Heat generatorRead
Party Timer heating circuit 1minRead and write
Setpoint Eco/Party heating circuit 1°CRead and write
Setpoint Eco/Party heating circuit 2°CRead and write
Party Timer heating circuit 2minRead and write
Operating phase AWRead
Operating modes heating circuit 1Read
Operating modes heating circuit 2Read
Operating modes DHWRead
Select mode BufferRead and write
Select mode AWRead
Charge Status%Read
Upper cold buffer temperature°CRead
Lower cold buffer temperature°CRead
SG Ready StatusRead and write
Operating hours for heatinghRead
Number of heating startscountRead
Heat quantity for heatingMWhRead
Number of cooling startscountRead
Amount of energy for coolingMWhRead
E-Heater operating hourshRead
Number of E-Heater startscountRead
External heat demand°CWrite

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Monitor flow temperatures, DHW temperature, and heat pump output on a live cloud dashboard for your customer.
  • Create an alert when an alarm code is reported by the Windhager heat generator to enable fast troubleshooting.
  • Track operating hours and energy quantities over time to verify system efficiency and plan maintenance intervals.
  • Control SG Ready status remotely to shift heat pump operation in response to dynamic electricity tariffs or PV surplus.
  • Adjust eco and party setpoints and timers from the cloud without requiring on-site access to the InfoWIN Touch display.
  • Log outside and room temperatures alongside heating circuit modes to optimize comfort and energy consumption.

Installation

  1. Contact Windhager Customer Service to update your Infinity Plus controller and InfoWIN Touch display to the required Modbus TCP firmware (V3.2.0 for InfoWIN Touch, V1.00+ for LOGWIN2/DOUWIN2, V1.33+ for AEROWIN DELUXE).

  2. Connect the ModbusCloud Gateway to the same local network as the Windhager system using an Ethernet cable.

  3. Configure the Modbus TCP connection parameters on the Windhager system via the InfoWIN Touch software, noting the IP address and TCP port.

  4. In the ModbusCloud portal, add a new device and import the Windhager heat pump template from the template library.

  5. Enter the IP address and port of the Windhager system in the gateway configuration and verify that data points appear on the dashboard.

  6. Test a control command, such as switching the heating circuit mode, to confirm bidirectional communication is working.

Things to watch for

My Windhager system does not respond to Modbus TCP requests. What should I check?

Verify that the InfoWIN Touch firmware has been updated to V3.2.0 and that the system software meets the minimum version (V1.00 for LOGWIN2/DOUWIN2, V1.33 for AEROWIN DELUXE). Confirm that the gateway and Windhager device are on the same subnet and that no firewall is blocking the Modbus TCP port.

Is my older Windhager system compatible with this template?

Systems based on MES+, MES Infinity, or Infinity-TA are not compatible. Only devices with the Infinity Plus controller and LAN capability can be updated to support Modbus TCP.

How do I obtain the firmware update for Modbus TCP?

The update can be ordered free of charge through Windhager Customer Service. They will provide the necessary firmware files and instructions for the InfoWIN Touch display and the heating system controller.

Which registers are used for SG Ready control?

The template includes a dedicated write register for SG Ready status. Consult the Windhager Modbus documentation for the exact register address and accepted values, and verify correct operation after setup.

Want to see how it works?