Windhager Best Heating Technology Log Wood Boiler
Monitors and controls Windhager log wood boilers via Modbus TCP
This template connects Windhager LogWIN2 log wood boilers to ModbusCloud via Modbus TCP. It reads boiler temperatures, buffer tank levels, heating circuit data, hot water status, and maintenance timers. It also allows control of heating modes, comfort setpoints, party timers, and ignition commands.
- Protocol
- Modbus TCP
- Connection
- Ethernet, Modbus TCP
- Registers
- 33, read and write
- Brand
- Windhager
- Key readings
- Boiler temperature and power · Buffer tank temperatures (top, mid, bottom) · Flow temperatures HK1 and HK2 · Hot water temperature actual/setpoint · Maintenance and cleaning remaining hours · Operating hours and pellet consumption
- Available commands
- Operating mode HK1/HK2/hot water · Comfort setpoint HK1/HK2 · Party timer HK1/HK2 and Eco/Party setpoints · Ignition command
- Compatible models
- LogWIN2 DELUXE · LogWIN2 EDEL
- Last updated
Registers (33)
32 read, 11 write
| Name | Unit | Access | Address (Hidden until you enter your email) | Function (hidden) | Type (hidden) |
|---|---|---|---|---|---|
| Kesseltemperatur ist | °C | Read | |||
| Kesseltemperatur soll | °C | Read | |||
| Kesselleistung | % | Read | |||
| Restlaufzeit bis Reinigung | h | Read | |||
| Temperatur Puffer oben | °C | Read | |||
| Temperatur Puffer mitte | °C | Read | |||
| Temperatur Puffer unten | °C | Read | |||
| Restlaufzeit bis Hauptreinigung | h | Read | |||
| Restlaufzeit bis Wartung | h | Read | |||
| Lagerraum Befüllgrad | % | Read | |||
| AT | °C | Read | |||
| Vorlauftemperatur HK1 | °C | Read | |||
| Vorlauftemperatur HK1 soll | °C | Read | |||
| Betriebswahl HK1 | Read and write | ||||
| Behaglichkeit HK1 | K | Read and write | |||
| Warmwasser ist | °C | Read | |||
| Warmwasser soll | °C | Read | |||
| Vorlauftemperatur HK2 | °C | Read | |||
| Vorlauftemperatur HK2 soll | °C | Read | |||
| Raumtemperatur HK1 | °C | Read | |||
| Betriebswahl HK2 | Read and write | ||||
| Betriebswahl WW | Read and write | ||||
| WW Einmalladung ist | Read and write | ||||
| Behaglichkeit HK2 | K | Read and write | |||
| Restlaufzeit bis Ascheentleerung | h | Read | |||
| Betriebsstunden | h | Read | |||
| Pelletsverbrauch | t | Read | |||
| Alarmcode Wärmeerzeuger | Read | ||||
| Party Timer HK1 | min | Read and write | |||
| Sollwert Eco/Party HK1 | °C | Read and write | |||
| Sollwert Eco/Party HK2 | °C | Read and write | |||
| Party Timer HK2 | min | Read and write | |||
| Zundkommando | Write |
Loading registers…
Send your device list
If a device is not in the library yet, we build the template for free as soon as we have the register data.
Use cases
- Monitor boiler temperature and buffer tank levels on a live cloud dashboard for residential heating customers.
- Create an alert when remaining maintenance hours drop below a threshold to schedule proactive service visits.
- Adjust comfort setpoints for HK1 and HK2 remotely without traveling to the installation site.
- Track pellet consumption and operating hours over time to optimize fuel purchasing and boiler efficiency.
- Activate the party timer remotely when a customer needs temporary heating outside the normal schedule.
- Log hot water temperature deviations from setpoint to diagnose domestic hot water performance issues.
Installation
Connect the ModbusCloud Gateway to the same local network as the Windhager LogWIN2 boiler via Ethernet.
Ensure the InfoWIN Touch display is updated to Modbus TCP software version V3.1.0 or higher by contacting Windhager Customer Service if needed.
Verify that the LogWIN2 boiler runs Software V1.00 or higher (available from April 2025).
Configure the Modbus TCP IP address and port on the InfoWIN Touch display so the gateway can reach the boiler.
Import the Windhager LogWIN2 log wood boiler template in the ModbusCloud platform and assign it to the connected gateway.
Confirm that sensor readings such as boiler temperature and buffer tank temperatures appear correctly on the ModbusCloud dashboard.
Things to watch for
Which Windhager models are supported by this template?
Only the LogWIN2 DELUXE and LogWIN2 EDEL are supported. The boiler must run Software V1.00 or higher. MES+, MES Infinity, and Infinity-TA systems are not compatible.
Do I need to update the InfoWIN Touch display before using Modbus TCP?
Yes. The InfoWIN Touch display must be updated to software version V3.1.0 or higher. Contact Windhager Customer Service to order the free update.
What data types and scaling are used for temperature registers?
Temperature values use int16 or uint16 data types with 1-degree Celsius resolution. No decimal scaling is applied. Time registers are expressed in hours or minutes.
Can I connect the gateway over Modbus RTU instead of TCP?
No. This template uses Modbus TCP only. The LogWIN2 boiler must be connected via Ethernet on a local network accessible by the ModbusCloud gateway.
Want to see how it works?