Windhager Windhager Best Heating Technology Log Wood Boiler Modbus TCP template

Windhager Best Heating Technology Log Wood Boiler

Monitors and controls Windhager log wood boilers via Modbus TCP

This template connects Windhager LogWIN2 log wood boilers to ModbusCloud via Modbus TCP. It reads boiler temperatures, buffer tank levels, heating circuit data, hot water status, and maintenance timers. It also allows control of heating modes, comfort setpoints, party timers, and ignition commands.

Protocol
Modbus TCP
Connection
Ethernet, Modbus TCP
Registers
33, read and write
Key readings
Boiler temperature and power · Buffer tank temperatures (top, mid, bottom) · Flow temperatures HK1 and HK2 · Hot water temperature actual/setpoint · Maintenance and cleaning remaining hours · Operating hours and pellet consumption
Available commands
Operating mode HK1/HK2/hot water · Comfort setpoint HK1/HK2 · Party timer HK1/HK2 and Eco/Party setpoints · Ignition command
Compatible models
LogWIN2 DELUXE · LogWIN2 EDEL
Last updated

Registers (33)

32 read, 11 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Kesseltemperatur ist°CRead
Kesseltemperatur soll°CRead
Kesselleistung%Read
Restlaufzeit bis ReinigunghRead
Temperatur Puffer oben°CRead
Temperatur Puffer mitte°CRead
Temperatur Puffer unten°CRead
Restlaufzeit bis HauptreinigunghRead
Restlaufzeit bis WartunghRead
Lagerraum Befüllgrad%Read
AT°CRead
Vorlauftemperatur HK1°CRead
Vorlauftemperatur HK1 soll°CRead
Betriebswahl HK1Read and write
Behaglichkeit HK1KRead and write
Warmwasser ist°CRead
Warmwasser soll°CRead
Vorlauftemperatur HK2°CRead
Vorlauftemperatur HK2 soll°CRead
Raumtemperatur HK1°CRead
Betriebswahl HK2Read and write
Betriebswahl WWRead and write
WW Einmalladung istRead and write
Behaglichkeit HK2KRead and write
Restlaufzeit bis AscheentleerunghRead
BetriebsstundenhRead
PelletsverbrauchtRead
Alarmcode WärmeerzeugerRead
Party Timer HK1minRead and write
Sollwert Eco/Party HK1°CRead and write
Sollwert Eco/Party HK2°CRead and write
Party Timer HK2minRead and write
ZundkommandoWrite

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Monitor boiler temperature and buffer tank levels on a live cloud dashboard for residential heating customers.
  • Create an alert when remaining maintenance hours drop below a threshold to schedule proactive service visits.
  • Adjust comfort setpoints for HK1 and HK2 remotely without traveling to the installation site.
  • Track pellet consumption and operating hours over time to optimize fuel purchasing and boiler efficiency.
  • Activate the party timer remotely when a customer needs temporary heating outside the normal schedule.
  • Log hot water temperature deviations from setpoint to diagnose domestic hot water performance issues.

Installation

  1. Connect the ModbusCloud Gateway to the same local network as the Windhager LogWIN2 boiler via Ethernet.

  2. Ensure the InfoWIN Touch display is updated to Modbus TCP software version V3.1.0 or higher by contacting Windhager Customer Service if needed.

  3. Verify that the LogWIN2 boiler runs Software V1.00 or higher (available from April 2025).

  4. Configure the Modbus TCP IP address and port on the InfoWIN Touch display so the gateway can reach the boiler.

  5. Import the Windhager LogWIN2 log wood boiler template in the ModbusCloud platform and assign it to the connected gateway.

  6. Confirm that sensor readings such as boiler temperature and buffer tank temperatures appear correctly on the ModbusCloud dashboard.

Things to watch for

Which Windhager models are supported by this template?

Only the LogWIN2 DELUXE and LogWIN2 EDEL are supported. The boiler must run Software V1.00 or higher. MES+, MES Infinity, and Infinity-TA systems are not compatible.

Do I need to update the InfoWIN Touch display before using Modbus TCP?

Yes. The InfoWIN Touch display must be updated to software version V3.1.0 or higher. Contact Windhager Customer Service to order the free update.

What data types and scaling are used for temperature registers?

Temperature values use int16 or uint16 data types with 1-degree Celsius resolution. No decimal scaling is applied. Time registers are expressed in hours or minutes.

Can I connect the gateway over Modbus RTU instead of TCP?

No. This template uses Modbus TCP only. The LogWIN2 boiler must be connected via Ethernet on a local network accessible by the ModbusCloud gateway.