WOLF WRS-K
Controls and monitors WOLF ventilation units via WRS-K Modbus interface.
This template connects to WOLF ventilation units via the WRS-K Modbus RTU interface. It reads temperatures, humidity, fan speeds, airflow volumes, heat recovery status, and fault indicators. It also allows control of operating mode, fan speeds, temperature setpoint, and on/off switching.
- Protocol
- Modbus RTU
- Connection
- RS485, 9600 baud
- Registers
- 22, read and write
- Brand
- Wolf
- Key readings
- Supply/Exhaust/Outside air temperature · Supply/Exhaust/Outside air humidity · Speed supply/exhaust air · Volume flow supply/exhaust air · Heat recovery · Collective fault
- Available commands
- Operating mode · Speed supply/exhaust air · Setpoint temperature · On-Off
- Compatible models
- WRS-K
- Last updated
Registers (22)
17 read, 5 write
| Name | Unit | Access | Address (Hidden until you enter your email) | Function (hidden) | Type (hidden) |
|---|---|---|---|---|---|
| Collective fault | Read | ||||
| Operational status | Read | ||||
| Supply air temperature | °C | Read | |||
| Exhaust air temperature | °C | Read | |||
| Status setpoint | Read | ||||
| Speed supply air | % | Read | |||
| Speed exhaust air | % | Read | |||
| Setpoint temperature | °C | Read | |||
| Supply air setpoint | °C | Read | |||
| Heat recovery | % | Read | |||
| Electric heater | % | Read | |||
| Outside air temperature | °C | Read | |||
| Exhaust air humidity | % | Read | |||
| Supply air humidity | % | Read | |||
| Outside air humidity | % | Read | |||
| Volume flow of supply air | m³/h | Read | |||
| Volume flow of exhaust air | m³/h | Read | |||
| Operating mode | Write | ||||
| Speed supply air | Write | ||||
| Speed exhaust air | Write | ||||
| Setpoint temperature | °C | Write | |||
| On-Off | Write |
Loading registers…
Send your device list
If a device is not in the library yet, we build the template for free as soon as we have the register data.
Use cases
- Monitor supply, exhaust, and outside air temperatures on a live dashboard to verify ventilation performance.
- Create an alert when a collective fault is reported by the WOLF ventilation unit so you can respond quickly.
- Adjust the supply air temperature setpoint remotely when a customer reports comfort issues.
- Track heat recovery status over time to detect degradation and schedule filter or exchanger maintenance.
- Switch the ventilation unit on or off remotely based on building occupancy or seasonal schedules.
- Log supply and exhaust airflow volumes to document compliance with ventilation regulations.
Installation
Wire the WRS-K interface to the ModbusCloud Gateway using a shielded RS-485 cable, connecting A, B, and GND terminals.
Set the Modbus slave address on the WRS-K module according to the WOLF documentation and ensure it does not conflict with other devices on the bus.
Confirm the baud rate is set to 9600 on both the WRS-K interface and the ModbusCloud gateway.
Import the WOLF WRS-K template in the ModbusCloud platform and assign it to the correct gateway and slave address.
Verify that live readings such as supply air temperature and fan speed appear on the dashboard before finalizing the installation.
Things to watch for
Why do I see incorrect values for certain registers even though communication is working?
The WRS-K register map reuses the same address for different data depending on the function code or offset. Make sure the template is using the correct function codes. Do not modify register mappings without consulting the WOLF WRS-K manual.
What baud rate and serial settings should I use?
The default is 9600 baud, 8 data bits, no parity, 1 stop bit (9600 8N1). These settings must match on both the WRS-K module and the Modbus gateway.
Can I connect multiple WOLF ventilation units on the same RS-485 bus?
Yes, as long as each WRS-K module has a unique Modbus slave address. Use proper bus topology with termination resistors at both ends of the cable.
Do I need a specific firmware version on the WOLF ventilation unit?
The WRS-K interface should work with any WOLF ventilation unit that supports this module. Check the WOLF compatibility list or manual at wolf-heiztechnik.at to confirm your specific model is supported.
More Wolf templates
Want to see how it works?