Alpha Innotec Modbus templates
All 3 available Alpha Innotec templates for ModbusCloud.
Monitor Alpha Innotec Luxtronic heat pumps, heating, cooling, DHW, via Modbus TCP.
- Templates
- 3
- Connection
- Modbus TCP
- Registers
- 13 to 15 per template
- Compatible models
- SWP · LWD · LWDRX · LW · LW-A · Hybrox · LWAV · LWA · LWP · Paros · LWCV · LWV · SWCV · WZSV · SW · SWC
- Last updated
Alpha Innotec templates
3 via Modbus TCP
Alpha Innotec Heating & Cooling LUX 2.0Control Alpha Innotec heatpumps via Modbus TCP for heating, cooling, and hot water management.Modbus TCP14 read, 6 write
Alpha Innotec Heating & Cooling SplitMonitors and controls Alpha Innotec split heat pumps via Modbus TCP.Modbus TCP8 read, 5 write
Alpha Innotec Heating & Cooling LUX 2.1 SHI Control Alpha Innotec heat pumps via Smart Home Interface over Modbus TCP.Modbus TCP4 read, 10 write
The scan recognises these devices
Connect them to RS485 or the network and start a scan in the portal.
Gateway
Portal
Incl. 4G data up to 30 MB per month
Excl. VAT. White label customer portal included. All prices
Order your first gateway100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

Alpha Innotec is a German manufacturer of brine-water, air-water and water-water heat pumps for residential and small-commercial heating. The 3 Alpha Innotec Modbus TCP templates in our library cover the LUX 2.0 Heating & Cooling system, the LUX 2.1 SHI heating/cooling pump with Smart-Home Interface, and the Alpha Innotec Heating & Cooling Split platform.
With ModbusCloud and these Alpha Innotec Modbus TCP templates you read supply, return, outdoor, brine, hot-water and room temperatures, operating hours, alarm status, setpoints, and power consumption (on Luxtronik 2.1). Writable registers control heating, cooling and hot water modes, holiday mode, alarm reset, and power-limit modes. The LUX 2.1 SHI variant adds DHW status and remote setpoint management through its Smart-Home Interface.
All 3 Alpha Innotec templates are free to browse. Import one into your ModbusCloud portal to supervise Alpha Innotec heat-pump installations from residential single-dwelling to multi-unit housing with centralised DHW management.
What you can read out
- Supply, return and outdoor temperatures
- Brine and hot-water temperatures
- Operating hours and alarm status
- Power consumption (LUX 2.1)
- Heating, cooling and hot-water mode
Typical installations
- Residential brine-water and air-water heat pumps
- Small-commercial heating with centralised DHW
- Smart-home installations via Luxtronik SHI interface
Want to see how it works?