Novelan Modbus templates
All 3 available Novelan templates for ModbusCloud.
Monitor Novelan heat pumps, heating, cooling and hot water, via Modbus RTU and Modbus TCP.
- Templates
- 3
- Connection
- Modbus RTU and TCP
- Registers
- 13 to 15 per template
- Compatible models
- Helox · LAD · LADV · LAV · LA · LAP · SICV · SIC · SI · SIP · Polaris · LICV · LIV · LI/HV · LI · WSV · LI 16.1 · SIV · WS
- Last updated
Novelan templates
1 via Modbus RTU, 2 via Modbus TCP
Novelan Heating & CoolingControls Novelan heat pumps for heating and cooling via Modbus TCP.Modbus TCP14 read, 6 write
Novelan Heating & Cooling Split Monitors and controls Novelan split heat pump heating and cooling systems via ModbusModbus RTU8 read, 5 write
Novelan Heating & Cooling WPRnet 2.1 SHIControls Novelan heat pumps via Modbus TCP Smart Home InterfaceModbus TCP4 read, 10 write
The scan recognises these devices
Connect them to RS485 or the network and start a scan in the portal.
Gateway
Portal
Incl. 4G data up to 30 MB per month
Excl. VAT. White label customer portal included. All prices
Order your first gateway100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

Novelan is a German heat-pump brand (part of the ai_Thermotec group, closely related to Alpha Innotec) producing residential and small-commercial brine-water, air-water and water-water heat pumps. The 3 Novelan Modbus templates in our library cover the Novelan Heating & Cooling main platform, the Heating & Cooling Split variant, and the WPRnet 2.1 SHI system with Smart-Home Interface.
With ModbusCloud and these Novelan Modbus RTU/TCP templates you read supply, return, outdoor, brine, hot-water and room temperatures, operating hours, setpoints, power consumption, alarm status, DHW status, and system states. Writable registers control heating, cooling, hot water and pool-blocking modes, holiday mode, setpoints, power-limitation modes, and alarm reset. The WPRnet 2.1 SHI adds level control and DHW management through its Smart-Home Interface.
All 3 Novelan templates are free to browse. Import one into your ModbusCloud portal to supervise Novelan heat-pump installations alongside Alpha Innotec or other heating equipment under one dashboard.
What you can read out
- Supply, return and outdoor temperatures
- Brine, hot-water and room temperatures
- Operating hours and alarm status
- Power consumption and DHW status
- Heating, cooling, hot water and pool modes
Typical installations
- Residential Novelan heat-pump installations
- Combined heat pump, cooling and pool heating
- Smart-home installations with Luxtronik SHI interface