Sigenergy Modbus templates
All 11 available Sigenergy templates for ModbusCloud.
Monitor Sigenergy SigenStor and Sigen hybrid energy storage systems over Modbus TCP.
- Templates
- 11
- Connection
- Modbus TCP
- Registers
- 1 to 6 per template
- Compatible models
- Sigen Hybrid · Sigen PV Max · SigenStore EC · SigenStor 5-25KW
- Last updated
Sigenergy templates
11 via Modbus TCP
Sigenergy SigenStore EC (grid)Modbus TCP5 read, 0 write
Sigenergy SigenStor PlantMonitors SigenStor energy storage system via Modbus TCPModbus TCP4 read, 0 write
Sigenergy SigenStor SlaveMonitors energy flow and battery data from SigenStor inverters via Modbus TCP.Modbus TCP6 read, 0 write
Sigenergy Sigen Hybrid (battery)Modbus TCP3 read, 1 write
Sigenergy Sigen Hybrid (grid)Modbus TCP5 read, 0 write
Sigenergy Sigen Hybrid (pv)Modbus TCP1 read, 0 write
Sigenergy Sigen PV Max (battery)Modbus TCP3 read, 1 write
Sigenergy Sigen PV Max (grid)Modbus TCP5 read, 0 write
Sigenergy Sigen PV Max (pv)Modbus TCP1 read, 0 write
Sigenergy SigenStore EC (battery)Modbus TCP3 read, 1 write
Sigenergy SigenStore EC (pv)Modbus TCP1 read, 0 write
The scan recognises these devices
Connect them to RS485 or the network and start a scan in the portal.
Gateway
Portal
Incl. 4G data up to 30 MB per month
Excl. VAT. White label customer portal included. All prices
Order your first gateway100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

Sigenergy builds integrated energy storage and hybrid inverter systems for residential and commercial solar. The templates here cover the SigenStor Plant (the site-level controller) and SigenStor Slave (stacked battery modules), plus the Sigen Hybrid, Sigen PV Max, and SigenStore EC product lines, each split into PV, grid, and battery register groups. In the field, Sigenergy is deployed as a modular stack where a Plant controller coordinates battery modules and an inverter section handles PV plus grid interaction.
ModbusCloud reads your Sigenergy system over Modbus TCP and brings energy flow and battery data into one view: PV generation, grid import and export, SigenStor battery state of charge, charge and discharge power, and inverter status. Because the Plant-Slave split is represented in the templates, you see the stacked battery modules individually rather than collapsed into one value, which matters when diagnosing a single slave that lags on charge acceptance. Alert rules fire on grid export loss, low SOC, and inverter fault codes.
All 11 Sigenergy templates are free to browse. Import the one that matches your installation into your ModbusCloud portal and read live data within minutes — no register mapping, no manufacturer PDFs.
What you can read out
- PV generation
- Grid import and export power
- SigenStor battery state of charge
- Battery charge and discharge power
- Inverter status and fault codes
Typical installations
- Residential PV homes with a Sigenergy SigenStor stacked battery system
- Commercial PV sites running Sigen Hybrid inverters with grid feed-in
- PV Max installations paired with SigenStor for higher self-consumption