Circuitor Circontrol eHome RS Modbus RTU template

Circontrol eHome RS

Controls a Circontrol eHome RS electric vehicle charger via Modbus RTU.

Template for the Circontrol eHome RS electric vehicle charger over Modbus RTU. It reads vehicle state, charging intensity, error codes, and load counters. It also allows control of charge intensity, station disabling, and stopping a charge session.

Protocol
Modbus RTU
Connection
RS485, 9600 baud
Registers
14, read and write
Key readings
State of Vehicle · Vehicle cable intensity · Intensity max. station · Last load counter (Min) · Current load counter (Min) · Error codes 1 to 3
Available commands
Intensity Charge · Intensity max. load · Disable Charge Station · Vehicle load stop
Compatible models
eHome RS
Last updated

Registers (14)

14 read, 6 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Intensity max. stationARead
Vehicle cable intensityARead
Intensity max. loadARead and write
Disable Charge StationRead and write
Gear Load of VehicleRead and write
Vehicle load stopRead and write
Temporary stop loading vehicleRead and write
State of VehicleRead
Intensity ChargeARead and write
Last load counter (Min)minRead
Current load counter (Min)minRead
Error code 1Read
Error code 2Read
Error code 3Read

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Monitor vehicle connection state and charging intensity on a live cloud dashboard for residential customers.
  • Create an alert when an error code appears on the eHome RS so you can respond before the customer calls.
  • Remotely stop or disable a charge session during peak grid demand to avoid capacity tariff penalties.
  • Log historical load counter data to generate monthly charging reports for fleet or household billing.
  • Adjust maximum charge intensity remotely to match available solar surplus on a PV-equipped home.
  • Combine EV charger data with energy meter readings in one dashboard for a complete site energy overview.

Installation

  1. Connect the ModbusCloud gateway RS-485 port (A and B terminals) to the Modbus RTU port on the Circontrol eHome RS, observing correct polarity.

  2. Set the eHome RS Modbus slave address to match the address configured in the ModbusCloud template, and confirm the baud rate is set to 9600.

  3. Power on both the gateway and the charger, then verify communication by checking for valid register readings in the gateway diagnostics.

  4. Import the Circontrol eHome RS template in the ModbusCloud platform and assign it to the corresponding gateway and slave address.

  5. Verify that key readings such as State of Vehicle and Intensity max. station appear correctly on the cloud dashboard.

  6. Test a write command, for example adjusting Intensity Charge, to confirm bidirectional communication is working.

Things to watch for

The gateway cannot read any registers from the eHome RS. What should I check?

Verify that the RS-485 wiring polarity (A to A, B to B) is correct and that a 120 ohm termination resistor is placed at the end of the bus if the cable run is long. Also confirm the slave address and baud rate (9600) match on both devices.

Can I use Modbus TCP instead of Modbus RTU with this charger?

The eHome RS supports Modbus RTU only. You need a gateway with an RS-485 serial port. Modbus TCP is not available on this model.

What data type do the registers use?

All registers are uint16 (unsigned 16-bit integer). No special byte order or scaling factors are documented beyond the default settings.

Is it safe to write to control registers while a vehicle is actively charging?

Yes, you can adjust charge intensity or stop a session while charging is in progress. The charger will apply the new setting immediately. Use caution with the Disable Charge Station register as it will prevent any new sessions until re-enabled.