MENNEKES AMTRON® 4You 400/500 & 4Business 700
Monitors and controls MENNEKES AMTRON EV charging stations with dynamic phase switching
This template connects MENNEKES AMTRON 4You 400, 4You 500, and 4Business 700 EV charging stations via Modbus TCP. It reads vehicle state, energy data, and per-phase electrical values while offering current and power limiting plus dynamic phase switching for 11kW models.
- Protocol
- Modbus TCP
- Connection
- Ethernet, Modbus TCP
- Registers
- 42, read and write
- Brand
- MENNEKES
- Key readings
- Vehicle State · Total Power / Total Energy · Voltage L1 to L3 · Current L1 to L3 · Phase Switch Status · HEMS Communication Status
- Available commands
- Current Limit (0.1A steps) · Power Limit · Charging Network EMS Current Limit L1-L3
- Compatible models
- AMTRON 4You 400 · AMTRON 4You 500 · AMTRON 4Business 700
- Last updated
Registers (42)
37 read, 5 write
| Name | Unit | Access | Address (Hidden until you enter your email) | Function (hidden) | Type (hidden) |
|---|---|---|---|---|---|
| Vehicle State | Read | ||||
| Operator Current Limit | A | Read | |||
| Total Energy | kWh | Read | |||
| Total Power | kW | Read | |||
| Signaled Current | A | Read | |||
| Charged Energy | Wh | Read | |||
| Charge Duration | s | Read | |||
| Current L1 | A | Read | |||
| Current L2 | A | Read | |||
| Current L3 | A | Read | |||
| Power L1 | W | Read | |||
| Power L2 | W | Read | |||
| Power L3 | W | Read | |||
| Voltage L1 | V | Read | |||
| Voltage L2 | V | Read | |||
| Voltage L3 | V | Read | |||
| Max Charging Current Limit | A | Read | |||
| Charging Point Network Mode | Read | ||||
| Charging Point Network Connected Charging Stations | count | Read | |||
| Charging Point Network Current Limit | A | Read | |||
| Charging Point Network Source of Limitation | Read | ||||
| Charging Point Network Overall Current Applied | A | Read | |||
| Charging Point Network Overall Current Available | A | Read | |||
| Modbus TCP / HEMS Configuration | Read | ||||
| HEMS Power Limit (Maximum) | W | Read | |||
| HEMS Communication Status | Read | ||||
| HEMS Power Limit (Minimum) | W | Read | |||
| Phase Switch Mode | Read | ||||
| Phase Switch Pause | Read | ||||
| Phase Switch Status | Read | ||||
| Assigned Phases | Read | ||||
| Charging Point Network Satellite Fallback Current | A | Read | |||
| Authorization Status | Read | ||||
| Charging Point Network Satellites in Fallback | count | Read | |||
| Charging Point Network Overall Current Consumption L1 | A | Read | |||
| Charging Point Network Overall Current Consumption L2 | A | Read | |||
| Charging Point Network Overall Current Consumption L3 | A | Read | |||
| Current Limit 0,1A steps | A | Write | |||
| Power Limit | W | Write | |||
| Charging Point Network EMS Current Limit L1 | A | Write | |||
| Charging Point Network EMS Current Limit L2 | A | Write | |||
| Charging Point Network EMS Current Limit L3 | A | Write |
Loading registers…
Send your device list
If a device is not in the library yet, we build the template for free as soon as we have the register data.
Use cases
- Monitor vehicle state and per-phase power draw on a live dashboard for each AMTRON wallbox on site.
- Set dynamic current limits based on available PV surplus to maximize solar self-consumption during charging.
- Create an alert when HEMS communication status indicates a lost connection between the wallbox and the gateway.
- Control automatic 1- to 3-phase switching on 11kW devices to optimize charging speed relative to available power.
- Track total energy delivered per wallbox to generate usage reports for tenants or fleet managers.
- Balance charging load across a local network of multiple AMTRON stations using per-phase EMS current limits.
Installation
Connect the ModbusCloud Gateway to the same IP network as the MENNEKES AMTRON wallbox.
Open the AMTRON web interface and activate Modbus TCP as well as the energy management system (HEMS).
For 11kW devices, enable Phase switching mode under Settings, Product and Installation, General in the wallbox web interface.
Verify the wallbox firmware is at least version 1.5.21 to access all HEMS registers, and at least 1.1.33 for power-limit-based phase switching.
In the ModbusCloud portal, import the MENNEKES AMTRON 4You/4Business template and assign the correct IP address and Modbus TCP port of the wallbox.
Confirm live data appears on the dashboard by checking vehicle state and voltage readings, then configure any desired current or power limits.
Things to watch for
Which firmware version do I need for full functionality?
Automatic phase change via the power limit register requires firmware 1.1.33 or later. For the full set of HEMS status registers and charging network support, update to firmware 1.5.21 or later. Enable automatic online updates in the wallbox web interface to stay current.
Dynamic phase switching is not working on my 11kW wallbox. What should I check?
Open the wallbox web interface and navigate to Settings, Product and Installation, General. Make sure Phase switching mode is activated. Also confirm the firmware is at least version 1.1.33.
What Modbus TCP port does the AMTRON wallbox use?
By default the AMTRON uses the standard Modbus TCP port 502. Verify this in the wallbox web interface after enabling Modbus, and enter the same port in the ModbusCloud gateway configuration.
Can I manage multiple AMTRON wallboxes from one gateway?
Yes. The template supports a local charging network of multiple 4You 400/500 and 4Business 700 units. Add each wallbox as a separate device in ModbusCloud using its own IP address, then use the per-phase EMS current limit registers for load balancing.