Pichler PKOM4
Heat pump combination unit for ventilation, heating, cooling and hot water in low energy homes.
The Pichler PKOM4 is a heat pump combination unit that ventilates, heats, cools and produces hot water in low energy and passive houses. This Modbus RTU template reads all temperatures, air flows, power, energy and errors and lets you write the operating mode, room and hot water setpoints and ventilation level from ModbusCloud.
- Protocol
- Modbus RTU
- Connection
- RS485, 19200 baud
- Registers
- 93, read and write
- Brand
- Pichler
- Key readings
- Room temperature · Supply and extract air temperature · Outdoor air temperature · Hot water tank temperature · Air flow · Electrical power · COP · CO2 and humidity
- Available commands
- Operating mode · Room setpoints · Hot water setpoint · Ventilation level
- Compatible models
- PKOM4
- Last updated
Registers (93)
93 read, 50 write
| Name | Unit | Access | Address (Hidden until you enter your email) | Function (hidden) | Type (hidden) |
|---|---|---|---|---|---|
| Operating Mode | Read and write | ||||
| Room Temperature Measurement | Read and write | ||||
| Auto Summer/winter Changeover | °C | Read and write | |||
| Active Cooling | Read and write | ||||
| Setpoint Room Normal | °C | Read and write | |||
| Setpoint Room Lowered | °C | Read and write | |||
| Setpoint Room Vacation | °C | Read and write | |||
| Room Sensor | Read and write | ||||
| Setpoint Room Active Cooling | °C | Read and write | |||
| Min. ODA Temp. To Enable Cooling | °C | Read and write | |||
| Automatic Room Temperature | Read and write | ||||
| SUP Setting Ventilation Level 1 | m³/h | Read and write | |||
| SUP Setting Ventilation Level 2 | m³/h | Read and write | |||
| SUP Setting Ventilation Level 3 | m³/h | Read and write | |||
| SUP Setting Ventilation Level 4 | m³/h | Read and write | |||
| ETA Balance | Read and write | ||||
| Selected Ventilation Level | Read and write | ||||
| Min. SUP Temperature Cooling | °C | Read and write | |||
| Max. SUP Temperature Heating | °C | Read and write | |||
| CO2 Concentration To High | ppm | Read and write | |||
| Relative Humidity To High | %RH | Read and write | |||
| Relative Humidity To Low | %RH | Read and write | |||
| Max. Control Voltage Duct Heater | V | Read and write | |||
| Setpoint DHW | °C | Read and write | |||
| Setpoint DHW - Ecotarif | °C | Read and write | |||
| E-heater DHW | Read and write | ||||
| Eco Tarif | Read and write | ||||
| Legionella Protection Function | Read and write | ||||
| Legionella Protection Interval | Read and write | ||||
| Setpoint Room Temp. Heating Circuit | °C | Read and write | |||
| Max. ODA Temperature To Enable Heating | °C | Read and write | |||
| Reset Errors | Read and write | ||||
| Operating Hours DHW_compressor | h | Read and write | |||
| Operating Hours HC_compressor | h | Read and write | |||
| Operating Hours ETA Fan | h | Read and write | |||
| Operating Hours ODA Fan | h | Read and write | |||
| Operating Hours K5 | h | Read and write | |||
| Operating Hours E-heater | h | Read and write | |||
| Operating Hours 4-way Valve | h | Read and write | |||
| Operating Hours Filter AUL & ABL | h | Read and write | |||
| DHW Release | Read and write | ||||
| DHW Timer Start Hour | Read and write | ||||
| DHW Timer Start Minute | Read and write | ||||
| DHW Timer Stop Hour | Read and write | ||||
| DHW Timer Stop Minute | Read and write | ||||
| Heating Circuit Release | Read and write | ||||
| Heating Circuit Timer Start Hour | Read and write | ||||
| Heating Circuit Timer Start Minute | Read and write | ||||
| Heating Circuit Timer Stop Hour | Read and write | ||||
| Heating Circuit Timer Stop Minute | Read and write | ||||
| Act. Fan Speed ETA | rpm | Read | |||
| Act. Fan Speed ODA | rpm | Read | |||
| Act. Room Temperature | °C | Read | |||
| Air Flow SUP | m³/h | Read | |||
| Air Flow ETA | m³/h | Read | |||
| Electr. Power DHW Comp. | W | Read | |||
| Electr. Power HC Comp. | W | Read | |||
| Electr. Power PCB+Fans | W | Read | |||
| Cooling Energy 12 Months | kWh | Read | |||
| T2 Display | °C | Read | |||
| Ventilation Energy 12 Months | kWh | Read | |||
| Booster E-heater Remaining Time | min | Read | |||
| Error Bits 0 To 15 | Read | ||||
| Error Bits 16 To 31 | Read | ||||
| Error Bits 32 To 47 | Read | ||||
| Error Bits 48 To 63 | Read | ||||
| Heating Capacity | W | Read | |||
| DHW Energy 12 Months | kWh | Read | |||
| SCOP Heat Pump 12 Months | Read | ||||
| COP Actual | Read | ||||
| PV Input | Read | ||||
| Heating Energy 12 Months | kWh | Read | |||
| Energy Consumption 12 Months | kWh | Read | |||
| T1 Supply Air | °C | Read | |||
| T3 Outdoor Air | °C | Read | |||
| T4 Exhaust Air | °C | Read | |||
| T7 Extract Air | °C | Read | |||
| T9 Duct Heater/solar Collector | °C | Read | |||
| T20 DHW Tank Temperature | °C | Read | |||
| T21 DHW Tank Temperature | °C | Read | |||
| Status Relais | Read | ||||
| Act. Capacity Compressor HC | % | Read | |||
| Status System | Read | ||||
| Status Fan ODA | Read | ||||
| Act. Ventilation Level SUP | Read | ||||
| Active Setpoint Room Temperature | °C | Read | |||
| Status Fan ETA | Read | ||||
| Active Setpoint DHW | °C | Read | |||
| Status Bypass | Read | ||||
| T40 Sensor External | °C | Read | |||
| CO2 Concentration | ppm | Read | |||
| Relative Humidity | %RH | Read | |||
| External Pump | % | Read |
Loading registers…
Send your device list
If a device is not in the library yet, we build the template for free as soon as we have the register data.
Use cases
- Show room, supply air and tank temperatures with the air flows of a PKOM4 on one dashboard.
- Send an email alert when one of the error words changes from zero.
- Keep 365 days of history of COP and energy for heating and hot water to check the heat pump.
- Change the operating mode or room setpoint remotely when residents are away on vacation.
- Raise the ventilation level when the CO2 value stays above the threshold you set.
Installation
Connect RS485 A and B of the PKOM4 to the RS485 port of the ModbusCloud Gateway and terminate both ends of the bus.
Check address, baud rate and parity in parameters 208 to 210 on the unit; from the factory it uses address 41, 19200 baud and even parity.
In ModbusCloud, add a Modbus device on the Gateway with the same address and serial settings, then import this template.
Check that the room temperature, outdoor air temperature and air flows arrive with plausible values.
Things to watch for
The PKOM4 does not answer on the RS485 bus. What should I check?
From the factory the unit answers on address 41, not 1, at 19200 baud with even parity. Match these settings, swap A and B if nothing comes back, and terminate only the two ends of the bus.
Why do temperatures look a hundred times too large?
Temperatures and temperature setpoints are sent with two decimals, so 2150 means 21.50 °C. The template applies that scale. If a value still looks wrong, check that the register uses the scale from the template and was not changed by hand.
Which registers can I write from ModbusCloud?
All setpoints in the holding registers: operating mode, room and hot water setpoints, ventilation levels and air volumes, thresholds, timers and the error reset. Stay inside the range given in each register comment and read the value back after writing.
How do I see which error is active?
Four registers hold 64 error bits, 16 per register. A value of zero means no error. The meaning of each bit is shown on the unit display; set an alert on any value above zero so you know when to look.
Can several units share one RS485 line?
Yes. Give every unit its own address with parameter 208 and use the same baud rate and parity on all devices. Run the bus as one line and terminate both ends.
Want to see how it works?