Rotronic Rotronic HygroFlex HF5A Modbus RTU template

Rotronic HygroFlex HF5A

Humidity and temperature transmitter with exchangeable probes, dew point and other calculated humidity values.

The Rotronic HygroFlex HF5A is a wall-mounted transmitter that measures relative humidity and temperature with an exchangeable probe in HVAC, food, pharmaceutical and other applications. This Modbus RTU template reads humidity, temperature, dew point and the other calculated humidity values, plus CO2 or differential pressure from a matching probe, and lets you set the Modbus address and byte order from ModbusCloud.

Protocol
Modbus RTU
Connection
RS485, 19200 baud
Registers
43, read and write
Key readings
Relative humidity · Temperature · Dew point · Frost point · Wet-bulb temperature · Enthalpy · CO2 concentration · Differential pressure
Available commands
Modbus address · Byte order
Compatible models
HF5A-D1D · HF5A-D1X
Last updated

Registers (43)

43 read, 2 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
Relative Humidity%RHRead
Temperature°CRead
Dew Point Temperature°CRead
Frost Point Temperature°CRead
Wet-Bulb Temperature°CRead
EnthalpyRead
Psychrometric DifferenceRead
Vapour ConcentrationRead
Saturation Vapour ConcentrationRead
Specific HumidityRead
Mixing RatioRead
Vapour Partial PressureRead
Vapour Saturation PressureRead
Volume Mixing RatioRead
CO2 ConcentrationppmRead
Differential PressureRead
Relative Humidity (Imperial)%RHRead
Temperature (Imperial)°FRead
Dew Point Temperature (Imperial)°FRead
Frost Point Temperature (Imperial)°FRead
Wet-Bulb Temperature (Imperial)°FRead
Enthalpy (Imperial)Read
Psychrometric Difference (Imperial)Read
Vapour Concentration (Imperial)Read
Saturation Vapour Concentration (Imperial)Read
Specific Humidity (Imperial)Read
Mixing Ratio (Imperial)Read
Vapour Partial Pressure (Imperial)Read
Vapour Saturation Pressure (Imperial)Read
Volume Mixing Ratio (Imperial)Read
CO2 Concentration (Imperial)ppmRead
Differential Pressure (Imperial)Read
Device FlagsRead
Measurement Flags Value 1Read
Measurement Flags Value 2Read
Next Calibration DateRead
Probe TypeRead
Probe Serial NumberRead
Device AddressRead and write
Byte OrderRead and write
Serial NumberRead
Vendor NameRead
Product TypeRead

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Show humidity, temperature and dew point per greenhouse compartment or production room on a dashboard with 365 days of history.
  • Get an email, in-app or webhook alert when relative humidity rises above or falls below the level your crop or process needs.
  • Plot the dew point next to the temperature to see when the air comes close to condensation.
  • With a CO2 or differential pressure probe fitted, alert on the CO2 level or the room pressure as well.
  • Export enthalpy, mixing ratio and vapour pressure as CSV or in a PDF report for climate and energy analysis.
  • Change the Modbus address from the portal before you add a second transmitter to the same bus.

Installation

  1. Use the digital version HF5A-D1 and supply it with 18 to 36 V DC on terminals K1-1 (V-) and K1-2 (V+).

  2. Connect RXTX+ (K2-1) and RXTX- (K2-2) to the RS485 data lines of the ModbusCloud Gateway and S-GND (K2-3) to signal ground. Terminate both ends of the bus with 120 ohm.

  3. Keep the defaults, address 247, 19200 baud, no parity, 8 data bits and 1 stop bit, or give each transmitter on a shared bus its own address.

  4. In ModbusCloud, add a Modbus device on the gateway with these settings and import the Rotronic HygroFlex HF5A template.

  5. Check that Vendor Name reads Rotronic and that Relative Humidity and Temperature show plausible values.

Things to watch for

The transmitter does not answer on the RS485 bus. What should I check?

Only the HF5A-D1 has RS485; the HF5A-21 and HF5A-31 have analog outputs only. Check address 247, 19200 baud, no parity, 8 data bits and 1 stop bit. Connect S-GND as well as RXTX+ and RXTX-. If nothing answers, swap RXTX+ and RXTX-, because manufacturers label A and B differently. Terminate both ends of the bus.

Humidity and temperature show huge or tiny numbers. Why?

The transmitter can send its 32-bit values in four byte orders, set in Byte Order. The template expects 0, big endian, which is the factory setting. If Byte Order shows 1, 2 or 3, the readings turn into very large or very small numbers. Set Byte Order back to 0 to fix it.

CO2 or Differential Pressure shows no sensible value. Is something wrong?

No. The HF5A only reports what the connected probe measures. A HygroClip2 humidity probe gives humidity and temperature, and the calculated values follow from those. CO2 and differential pressure need a matching Rotronic probe on a 3- or 4-wire transmitter, and a temperature probe gives no humidity values.

Can I change the Modbus address from ModbusCloud?

Yes, Device Address and Byte Order are writable. After a new address is written, the transmitter replies once on its old address and then switches, so update the address of the Modbus device in ModbusCloud right after. Writing registers in ModbusCloud is off by default and is enabled per gateway on request. The baud rate and other settings are changed with HygroSoft over NFC.

How do I connect several HF5A transmitters to one bus?

Every HF5A ships with address 247. Connect them one at a time, give each a new address in Device Address and only then wire the next one. Keep the same baud rate and parity on every device on the bus, and terminate only the two ends.