SATEC PM130 PLUS Min/Max Log
Panel meter log of minimum and maximum voltage, current, power and demand values with time stamps.
The SATEC PM130 PLUS is a three-phase panel meter that keeps a log of minimum and maximum values in switchboards and substations. This Modbus RTU template reads the logged extremes of voltage, current, power, power factor and frequency, and the maximum demands per tariff, each with its time stamp, into ModbusCloud.
- Protocol
- Modbus RTU
- Connection
- RS485, 19200 baud
- Registers
- 144, read only
- Brand
- SATEC
- Key readings
- Minimum and maximum voltage · Minimum and maximum current · Minimum and maximum power · Maximum demand · Maximum demand per tariff · Time of each extreme
- Compatible models
- PM130P PLUS · PM130E PLUS · PM130EH PLUS
- Last updated
Registers (144)
144 read, 0 write
| Name | Unit | Access | Address (Hidden until you enter your email) | Function (hidden) | Type (hidden) |
|---|---|---|---|---|---|
| Minimum V1/V12 Voltage | V | Read | 35840 | FC03 | uint32 |
| Minimum V1/V12 Voltage Time | s | Read | 35842 | FC03 | uint32 |
| Minimum V2/V23 Voltage | V | Read | 35844 | FC03 | uint32 |
| Minimum V2/V23 Voltage Time | s | Read | 35846 | FC03 | uint32 |
| Minimum V3/V31 Voltage | V | Read | 35848 | FC03 | uint32 |
| Minimum V3/V31 Voltage Time | s | Read | |||
| Minimum I1 Current | A | Read | |||
| Minimum I1 Current Time | s | Read | |||
| Minimum I2 Current | A | Read | |||
| Minimum I2 Current Time | s | Read | |||
| Minimum I3 Current | A | Read | |||
| Minimum I3 Current Time | s | Read | |||
| Maximum V1/V12 Voltage | V | Read | |||
| Maximum V1/V12 Voltage Time | s | Read | |||
| Maximum V2/V23 Voltage | V | Read | |||
| Maximum V2/V23 Voltage Time | s | Read | |||
| Maximum V3/V31 Voltage | V | Read | |||
| Maximum V3/V31 Voltage Time | s | Read | |||
| Maximum I1 Current | A | Read | |||
| Maximum I1 Current Time | s | Read | |||
| Maximum I2 Current | A | Read | |||
| Maximum I2 Current Time | s | Read | |||
| Maximum I3 Current | A | Read | |||
| Maximum I3 Current Time | s | Read | |||
| Minimum Total kW | kW | Read | |||
| Minimum Total kW Time | s | Read | |||
| Minimum Total kvar | kvar | Read | |||
| Minimum Total kvar Time | s | Read | |||
| Minimum Total kVA | kVA | Read | |||
| Minimum Total kVA Time | s | Read | |||
| Minimum Total Power Factor | Read | ||||
| Minimum Total Power Factor Time | s | Read | |||
| Maximum Total kW | kW | Read | |||
| Maximum Total kW Time | s | Read | |||
| Maximum Total kvar | kvar | Read | |||
| Maximum Total kvar Time | s | Read | |||
| Maximum Total kVA | kVA | Read | |||
| Maximum Total kVA Time | s | Read | |||
| Maximum Total Power Factor | Read | ||||
| Maximum Total Power Factor Time | s | Read | |||
| Minimum Neutral Current | A | Read | |||
| Minimum Neutral Current Time | s | Read | |||
| Minimum Frequency | Hz | Read | |||
| Minimum Frequency Time | s | Read | |||
| Maximum Neutral Current | A | Read | |||
| Maximum Neutral Current Time | s | Read | |||
| Maximum Frequency | Hz | Read | |||
| Maximum Frequency Time | s | Read | |||
| Summary Register 1 Maximum Demand | Read | ||||
| Summary Register 1 Maximum Demand Time | s | Read | |||
| Summary Register 2 Maximum Demand | Read | ||||
| Summary Register 2 Maximum Demand Time | s | Read | |||
| Summary Register 3 Maximum Demand | Read | ||||
| Summary Register 3 Maximum Demand Time | s | Read | |||
| Summary Register 4 Maximum Demand | Read | ||||
| Summary Register 4 Maximum Demand Time | s | Read | |||
| V1/V12 Maximum Volt Demand | V | Read | |||
| V1/V12 Maximum Volt Demand Time | s | Read | |||
| V2/V23 Maximum Volt Demand | V | Read | |||
| V2/V23 Maximum Volt Demand Time | s | Read | |||
| V3/V31 Maximum Volt Demand | V | Read | |||
| V3/V31 Maximum Volt Demand Time | s | Read | |||
| I1 Maximum Ampere Demand | A | Read | |||
| I1 Maximum Ampere Demand Time | s | Read | |||
| I2 Maximum Ampere Demand | A | Read | |||
| I2 Maximum Ampere Demand Time | s | Read | |||
| I3 Maximum Ampere Demand | A | Read | |||
| I3 Maximum Ampere Demand Time | s | Read | |||
| Maximum kW Import Sliding Window Demand | kW | Read | |||
| Maximum kW Import Sliding Window Demand Time | s | Read | |||
| Maximum kvar Import Sliding Window Demand | kvar | Read | |||
| Maximum kvar Import Sliding Window Demand Time | s | Read | |||
| Maximum kVA Sliding Window Demand | kVA | Read | |||
| Maximum kVA Sliding Window Demand Time | s | Read | |||
| Maximum kW Export Sliding Window Demand | kW | Read | |||
| Maximum kW Export Sliding Window Demand Time | s | Read | |||
| Maximum kvar Export Sliding Window Demand | kvar | Read | |||
| Maximum kvar Export Sliding Window Demand Time | s | Read | |||
| In Maximum Ampere Demand | A | Read | |||
| In Maximum Ampere Demand Time | s | Read | |||
| TOU Register 1 Tariff 1 Maximum Demand | Read | ||||
| TOU Register 1 Tariff 1 Maximum Demand Time | s | Read | |||
| TOU Register 1 Tariff 2 Maximum Demand | Read | ||||
| TOU Register 1 Tariff 2 Maximum Demand Time | s | Read | |||
| TOU Register 1 Tariff 3 Maximum Demand | Read | ||||
| TOU Register 1 Tariff 3 Maximum Demand Time | s | Read | |||
| TOU Register 1 Tariff 4 Maximum Demand | Read | ||||
| TOU Register 1 Tariff 4 Maximum Demand Time | s | Read | |||
| TOU Register 1 Tariff 5 Maximum Demand | Read | ||||
| TOU Register 1 Tariff 5 Maximum Demand Time | s | Read | |||
| TOU Register 1 Tariff 6 Maximum Demand | Read | ||||
| TOU Register 1 Tariff 6 Maximum Demand Time | s | Read | |||
| TOU Register 1 Tariff 7 Maximum Demand | Read | ||||
| TOU Register 1 Tariff 7 Maximum Demand Time | s | Read | |||
| TOU Register 1 Tariff 8 Maximum Demand | Read | ||||
| TOU Register 1 Tariff 8 Maximum Demand Time | s | Read | |||
| TOU Register 2 Tariff 1 Maximum Demand | Read | ||||
| TOU Register 2 Tariff 1 Maximum Demand Time | s | Read | |||
| TOU Register 2 Tariff 2 Maximum Demand | Read | ||||
| TOU Register 2 Tariff 2 Maximum Demand Time | s | Read | |||
| TOU Register 2 Tariff 3 Maximum Demand | Read | ||||
| TOU Register 2 Tariff 3 Maximum Demand Time | s | Read | |||
| TOU Register 2 Tariff 4 Maximum Demand | Read | ||||
| TOU Register 2 Tariff 4 Maximum Demand Time | s | Read | |||
| TOU Register 2 Tariff 5 Maximum Demand | Read | ||||
| TOU Register 2 Tariff 5 Maximum Demand Time | s | Read | |||
| TOU Register 2 Tariff 6 Maximum Demand | Read | ||||
| TOU Register 2 Tariff 6 Maximum Demand Time | s | Read | |||
| TOU Register 2 Tariff 7 Maximum Demand | Read | ||||
| TOU Register 2 Tariff 7 Maximum Demand Time | s | Read | |||
| TOU Register 2 Tariff 8 Maximum Demand | Read | ||||
| TOU Register 2 Tariff 8 Maximum Demand Time | s | Read | |||
| TOU Register 3 Tariff 1 Maximum Demand | Read | ||||
| TOU Register 3 Tariff 1 Maximum Demand Time | s | Read | |||
| TOU Register 3 Tariff 2 Maximum Demand | Read | ||||
| TOU Register 3 Tariff 2 Maximum Demand Time | s | Read | |||
| TOU Register 3 Tariff 3 Maximum Demand | Read | ||||
| TOU Register 3 Tariff 3 Maximum Demand Time | s | Read | |||
| TOU Register 3 Tariff 4 Maximum Demand | Read | ||||
| TOU Register 3 Tariff 4 Maximum Demand Time | s | Read | |||
| TOU Register 3 Tariff 5 Maximum Demand | Read | ||||
| TOU Register 3 Tariff 5 Maximum Demand Time | s | Read | |||
| TOU Register 3 Tariff 6 Maximum Demand | Read | ||||
| TOU Register 3 Tariff 6 Maximum Demand Time | s | Read | |||
| TOU Register 3 Tariff 7 Maximum Demand | Read | ||||
| TOU Register 3 Tariff 7 Maximum Demand Time | s | Read | |||
| TOU Register 3 Tariff 8 Maximum Demand | Read | ||||
| TOU Register 3 Tariff 8 Maximum Demand Time | s | Read | |||
| TOU Register 4 Tariff 1 Maximum Demand | Read | ||||
| TOU Register 4 Tariff 1 Maximum Demand Time | s | Read | |||
| TOU Register 4 Tariff 2 Maximum Demand | Read | ||||
| TOU Register 4 Tariff 2 Maximum Demand Time | s | Read | |||
| TOU Register 4 Tariff 3 Maximum Demand | Read | ||||
| TOU Register 4 Tariff 3 Maximum Demand Time | s | Read | |||
| TOU Register 4 Tariff 4 Maximum Demand | Read | ||||
| TOU Register 4 Tariff 4 Maximum Demand Time | s | Read | |||
| TOU Register 4 Tariff 5 Maximum Demand | Read | ||||
| TOU Register 4 Tariff 5 Maximum Demand Time | s | Read | |||
| TOU Register 4 Tariff 6 Maximum Demand | Read | ||||
| TOU Register 4 Tariff 6 Maximum Demand Time | s | Read | |||
| TOU Register 4 Tariff 7 Maximum Demand | Read | ||||
| TOU Register 4 Tariff 7 Maximum Demand Time | s | Read | |||
| TOU Register 4 Tariff 8 Maximum Demand | Read | ||||
| TOU Register 4 Tariff 8 Maximum Demand Time | s | Read |
Loading registers…
Send your device list
If a device is not in the library yet, we build the template for free as soon as we have the register data.
Use cases
- Show the highest current per phase and when it occurred on a ModbusCloud dashboard.
- Send an alarm when the maximum kW demand of the month passes the contracted capacity.
- Keep the minimum voltage per phase in history to find dips on a feeder.
- Compare maximum demand per tariff between months for an energy report.
- Check the time of the last maximum demand before you discuss a peak with the customer.
Installation
Wire the RS485 port of the PM130 PLUS to the ModbusCloud Gateway, A to A and B to B, with termination at the end of the bus.
Check the Modbus address, baud rate and parity of the meter in its communication setup.
In ModbusCloud add a Modbus device on the Gateway with the same address as the main PM130 PLUS template, and import this template.
Check that the maximum values and time stamps arrive; a time of 0 means the value has not been logged yet.
Things to watch for
Why are the maximum demand values zero?
Power and tariff demands are only measured by PM130E and PM130EH meters. On a PM130P these registers stay at zero. On E models check that the demand period has passed at least once since the log was cleared.
How do I read the time stamps?
Each time stamp is the number of seconds since 1 January 1970 as kept by the meter clock. Set the meter clock correctly, otherwise the moments in the log are shifted.
The values are a factor 10 or 100 off. What is wrong?
The meter has a low and a high resolution option. This template assumes the default low resolution: 1 V, 1 A and 1 kW. With high resolution and PT ratio 1 the meter returns 0.1 V, 0.01 A and 1 W, so change the scale of those registers.
Can I clear the min/max log from ModbusCloud?
Not with this template, which only reads. The clear command is in the PM130 PLUS control and status template.