SATEC SATEC PM130 PLUS Modbus RTU template

SATEC PM130 PLUS

Three-phase panel power meter for voltage, current, power, energy, demand and harmonics.

The SATEC PM130 PLUS is a three-phase power meter that measures voltage, current, power, energy, demand and harmonics in switchboards and substations. This Modbus RTU template reads all real-time values, energies, harmonics and min/max values and lets you set counters, analog outputs and the register map from ModbusCloud.

Protocol
Modbus RTU
Connection
RS485, 19200 baud
Registers
1043, read and write
Brand
SATEC
Key readings
Phase voltages · Phase currents · Active power · Power factor · Frequency · Imported energy · Voltage and current THD · Maximum demand
Available commands
Pulse counters · Analog outputs · Assignable register map · Voltage and current scale
Compatible models
PM130P PLUS · PM130E PLUS · PM130EH PLUS
Last updated

Registers (1043)

1043 read, 251 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
V1/V12 VoltageVRead
V2/V23 VoltageVRead
V3/V31 VoltageVRead
I1 CurrentARead
I2 CurrentARead
I3 CurrentARead
kW L1kWRead
kW L2kWRead
kW L3kWRead
kvar L1kvarRead
kvar L2kvarRead
kvar L3kvarRead
kVA L1kVARead
kVA L2kVARead
kVA L3kVARead
Power Factor L1Read
Power Factor L2Read
Power Factor L3Read
V1/V12 Voltage THD%Read
V2/V23 Voltage THD%Read
V3/V31 Voltage THD%Read
I1 Current THD%Read
I2 Current THD%Read
I3 Current THD%Read
I1 K-FactorRead
I2 K-FactorRead
I3 K-FactorRead
I1 Current TDD%Read
I2 Current TDD%Read
I3 Current TDD%Read
V12 VoltageVRead
V23 VoltageVRead
V31 VoltageVRead
Total kWkWRead
Total kvarkvarRead
Total kVAkVARead
Total PFRead
Total PF LagRead
Total PF LeadRead
Total kW ImportkWRead
Total kW ExportkWRead
Total kvar ImportkvarRead
Total kvar ExportkvarRead
3-phase Average L-N/L-L VoltageVRead
3-phase Average L-L VoltageVRead
3-phase Average CurrentARead
In (neutral) CurrentARead
FrequencyHzRead
Voltage Unbalance%Read
Current Unbalance%Read
Frequency High ResolutionHzRead
V1/V12 Volt DemandVRead
V2/V23 Volt DemandVRead
V3/V31 Volt DemandVRead
I1 Ampere DemandARead
I2 Ampere DemandARead
I3 Ampere DemandARead
kW Import Block DemandkWRead
kvar Import Block DemandkvarRead
kVA Block DemandkVARead
kW Import Sliding Window DemandkWRead
kvar Import Sliding Window DemandkvarRead
kVA Sliding Window DemandkVARead
kW Import Accumulated DemandkWRead
kvar Import Accumulated DemandkvarRead
kVA Accumulated DemandkVARead
kW Import Predicted Sliding Window DemandkWRead
kvar Import Predicted Sliding Window DemandkvarRead
kVA Predicted Sliding Window DemandkVARead
PF (import) at Max. kVA Sliding Window DemandRead
kW Export Block DemandkWRead
kvar Export Block DemandkvarRead
kW Export Sliding Window DemandkWRead
kvar Export Sliding Window DemandkvarRead
kW Export Accumulated DemandkWRead
kvar Export Accumulated DemandkvarRead
kW Export Predicted Sliding Window DemandkWRead
kvar Export Predicted Sliding Window DemandkvarRead
In Ampere DemandARead
kWh ImportkWhRead
kWh ExportkWhRead
kvarh ImportkvarhRead
kvarh ExportkvarhRead
kVAh TotalkVAhRead
kVAh ImportkVAhRead
kVAh ExportkVAhRead
kvarh Q1kvarhRead
kvarh Q2kvarhRead
kvarh Q3kvarhRead
kvarh Q4kvarhRead
Summary Energy Register #1kWhRead
Summary Energy Register #2kWhRead
Summary Energy Register #3kWhRead
Summary Energy Register #4kWhRead
kWh Import L1kWhRead
kWh Import L2kWhRead
kWh Import L3kWhRead
kvarh Import L1kvarhRead
kvarh Import L2kvarhRead
kvarh Import L3kvarhRead
kVAh Total L1kVAhRead
kVAh Total L2kVAhRead
kVAh Total L3kVAhRead
V1/V12 Voltage 1-CycleVRead
V2/V23 Voltage 1-CycleVRead
V3/V31 Voltage 1-CycleVRead
I1 Current 1-CycleARead
I2 Current 1-CycleARead
I3 Current 1-CycleARead
kW L1 1-CyclekWRead
kW L2 1-CyclekWRead
kW L3 1-CyclekWRead
kvar L1 1-CyclekvarRead
kvar L2 1-CyclekvarRead
kvar L3 1-CyclekvarRead
kVA L1 1-CyclekVARead
kVA L2 1-CyclekVARead
kVA L3 1-CyclekVARead
Power Factor L1 1-CycleRead
Power Factor L2 1-CycleRead
Power Factor L3 1-CycleRead
V1/V12 Voltage THD 1-Cycle%Read
V2/V23 Voltage THD 1-Cycle%Read
V3/V31 Voltage THD 1-Cycle%Read
I1 Current THD 1-Cycle%Read
I2 Current THD 1-Cycle%Read
I3 Current THD 1-Cycle%Read
I1 K-Factor 1-CycleRead
I2 K-Factor 1-CycleRead
I3 K-Factor 1-CycleRead
I1 Current TDD 1-Cycle%Read
I2 Current TDD 1-Cycle%Read
I3 Current TDD 1-Cycle%Read
V12 Voltage 1-CycleVRead
V23 Voltage 1-CycleVRead
V31 Voltage 1-CycleVRead
Total kW 1-CyclekWRead
Total kvar 1-CyclekvarRead
Total kVA 1-CyclekVARead
Total PF 1-CycleRead
Total PF Lag 1-CycleRead
Total PF Lead 1-CycleRead
Total kW Import 1-CyclekWRead
Total kW Export 1-CyclekWRead
Total kvar Import 1-CyclekvarRead
Total kvar Export 1-CyclekvarRead
3-phase Average L-N/L-L Voltage 1-CycleVRead
3-phase Average L-L Voltage 1-CycleVRead
3-phase Average Current 1-CycleARead
In (neutral) Current 1-CycleARead
Frequency 1-CycleHzRead
Voltage Unbalance 1-Cycle%Read
Current Unbalance 1-Cycle%Read
Frequency High Resolution 1-CycleHzRead
V1/V12 Voltage MagnitudeVRead
V2/V23 Voltage MagnitudeVRead
V3/V31 Voltage MagnitudeVRead
I1 Current MagnitudeARead
I2 Current MagnitudeARead
I3 Current MagnitudeARead
V1/V12 Voltage Angle°Read
V2/V23 Voltage Angle°Read
V3/V31 Voltage Angle°Read
I1 Current Angle°Read
I2 Current Angle°Read
I3 Current Angle°Read
Phase Rotation OrderRead
Digital InputsRead
Relay OutputsRead
Counter #1Read and write
Counter #2Read and write
Counter #3Read and write
Counter #4Read and write
V1/V12 H01 Harmonic Distortion%Read
V1/V12 H02 Harmonic Distortion%Read
V1/V12 H03 Harmonic Distortion%Read
V1/V12 H04 Harmonic Distortion%Read
V1/V12 H05 Harmonic Distortion%Read
V1/V12 H06 Harmonic Distortion%Read
V1/V12 H07 Harmonic Distortion%Read
V1/V12 H08 Harmonic Distortion%Read
V1/V12 H09 Harmonic Distortion%Read
V1/V12 H10 Harmonic Distortion%Read
V1/V12 H11 Harmonic Distortion%Read
V1/V12 H12 Harmonic Distortion%Read
V1/V12 H13 Harmonic Distortion%Read
V1/V12 H14 Harmonic Distortion%Read
V1/V12 H15 Harmonic Distortion%Read
V1/V12 H16 Harmonic Distortion%Read
V1/V12 H17 Harmonic Distortion%Read
V1/V12 H18 Harmonic Distortion%Read
V1/V12 H19 Harmonic Distortion%Read
V1/V12 H20 Harmonic Distortion%Read
V1/V12 H21 Harmonic Distortion%Read
V1/V12 H22 Harmonic Distortion%Read
V1/V12 H23 Harmonic Distortion%Read
V1/V12 H24 Harmonic Distortion%Read
V1/V12 H25 Harmonic Distortion%Read
V1/V12 H26 Harmonic Distortion%Read
V1/V12 H27 Harmonic Distortion%Read
V1/V12 H28 Harmonic Distortion%Read
V1/V12 H29 Harmonic Distortion%Read
V1/V12 H30 Harmonic Distortion%Read
V1/V12 H31 Harmonic Distortion%Read
V1/V12 H32 Harmonic Distortion%Read
V1/V12 H33 Harmonic Distortion%Read
V1/V12 H34 Harmonic Distortion%Read
V1/V12 H35 Harmonic Distortion%Read
V1/V12 H36 Harmonic Distortion%Read
V1/V12 H37 Harmonic Distortion%Read
V1/V12 H38 Harmonic Distortion%Read
V1/V12 H39 Harmonic Distortion%Read
V1/V12 H40 Harmonic Distortion%Read
V2/V23 H01 Harmonic Distortion%Read
V2/V23 H02 Harmonic Distortion%Read
V2/V23 H03 Harmonic Distortion%Read
V2/V23 H04 Harmonic Distortion%Read
V2/V23 H05 Harmonic Distortion%Read
V2/V23 H06 Harmonic Distortion%Read
V2/V23 H07 Harmonic Distortion%Read
V2/V23 H08 Harmonic Distortion%Read
V2/V23 H09 Harmonic Distortion%Read
V2/V23 H10 Harmonic Distortion%Read
V2/V23 H11 Harmonic Distortion%Read
V2/V23 H12 Harmonic Distortion%Read
V2/V23 H13 Harmonic Distortion%Read
V2/V23 H14 Harmonic Distortion%Read
V2/V23 H15 Harmonic Distortion%Read
V2/V23 H16 Harmonic Distortion%Read
V2/V23 H17 Harmonic Distortion%Read
V2/V23 H18 Harmonic Distortion%Read
V2/V23 H19 Harmonic Distortion%Read
V2/V23 H20 Harmonic Distortion%Read
V2/V23 H21 Harmonic Distortion%Read
V2/V23 H22 Harmonic Distortion%Read
V2/V23 H23 Harmonic Distortion%Read
V2/V23 H24 Harmonic Distortion%Read
V2/V23 H25 Harmonic Distortion%Read
V2/V23 H26 Harmonic Distortion%Read
V2/V23 H27 Harmonic Distortion%Read
V2/V23 H28 Harmonic Distortion%Read
V2/V23 H29 Harmonic Distortion%Read
V2/V23 H30 Harmonic Distortion%Read
V2/V23 H31 Harmonic Distortion%Read
V2/V23 H32 Harmonic Distortion%Read
V2/V23 H33 Harmonic Distortion%Read
V2/V23 H34 Harmonic Distortion%Read
V2/V23 H35 Harmonic Distortion%Read
V2/V23 H36 Harmonic Distortion%Read
V2/V23 H37 Harmonic Distortion%Read
V2/V23 H38 Harmonic Distortion%Read
V2/V23 H39 Harmonic Distortion%Read
V2/V23 H40 Harmonic Distortion%Read
V3/V31 H01 Harmonic Distortion%Read
V3/V31 H02 Harmonic Distortion%Read
V3/V31 H03 Harmonic Distortion%Read
V3/V31 H04 Harmonic Distortion%Read
V3/V31 H05 Harmonic Distortion%Read
V3/V31 H06 Harmonic Distortion%Read
V3/V31 H07 Harmonic Distortion%Read
V3/V31 H08 Harmonic Distortion%Read
V3/V31 H09 Harmonic Distortion%Read
V3/V31 H10 Harmonic Distortion%Read
V3/V31 H11 Harmonic Distortion%Read
V3/V31 H12 Harmonic Distortion%Read
V3/V31 H13 Harmonic Distortion%Read
V3/V31 H14 Harmonic Distortion%Read
V3/V31 H15 Harmonic Distortion%Read
V3/V31 H16 Harmonic Distortion%Read
V3/V31 H17 Harmonic Distortion%Read
V3/V31 H18 Harmonic Distortion%Read
V3/V31 H19 Harmonic Distortion%Read
V3/V31 H20 Harmonic Distortion%Read
V3/V31 H21 Harmonic Distortion%Read
V3/V31 H22 Harmonic Distortion%Read
V3/V31 H23 Harmonic Distortion%Read
V3/V31 H24 Harmonic Distortion%Read
V3/V31 H25 Harmonic Distortion%Read
V3/V31 H26 Harmonic Distortion%Read
V3/V31 H27 Harmonic Distortion%Read
V3/V31 H28 Harmonic Distortion%Read
V3/V31 H29 Harmonic Distortion%Read
V3/V31 H30 Harmonic Distortion%Read
V3/V31 H31 Harmonic Distortion%Read
V3/V31 H32 Harmonic Distortion%Read
V3/V31 H33 Harmonic Distortion%Read
V3/V31 H34 Harmonic Distortion%Read
V3/V31 H35 Harmonic Distortion%Read
V3/V31 H36 Harmonic Distortion%Read
V3/V31 H37 Harmonic Distortion%Read
V3/V31 H38 Harmonic Distortion%Read
V3/V31 H39 Harmonic Distortion%Read
V3/V31 H40 Harmonic Distortion%Read
I1 H01 Harmonic Distortion%Read
I1 H02 Harmonic Distortion%Read
I1 H03 Harmonic Distortion%Read
I1 H04 Harmonic Distortion%Read
I1 H05 Harmonic Distortion%Read
I1 H06 Harmonic Distortion%Read
I1 H07 Harmonic Distortion%Read
I1 H08 Harmonic Distortion%Read
I1 H09 Harmonic Distortion%Read
I1 H10 Harmonic Distortion%Read
I1 H11 Harmonic Distortion%Read
I1 H12 Harmonic Distortion%Read
I1 H13 Harmonic Distortion%Read
I1 H14 Harmonic Distortion%Read
I1 H15 Harmonic Distortion%Read
I1 H16 Harmonic Distortion%Read
I1 H17 Harmonic Distortion%Read
I1 H18 Harmonic Distortion%Read
I1 H19 Harmonic Distortion%Read
I1 H20 Harmonic Distortion%Read
I1 H21 Harmonic Distortion%Read
I1 H22 Harmonic Distortion%Read
I1 H23 Harmonic Distortion%Read
I1 H24 Harmonic Distortion%Read
I1 H25 Harmonic Distortion%Read
I1 H26 Harmonic Distortion%Read
I1 H27 Harmonic Distortion%Read
I1 H28 Harmonic Distortion%Read
I1 H29 Harmonic Distortion%Read
I1 H30 Harmonic Distortion%Read
I1 H31 Harmonic Distortion%Read
I1 H32 Harmonic Distortion%Read
I1 H33 Harmonic Distortion%Read
I1 H34 Harmonic Distortion%Read
I1 H35 Harmonic Distortion%Read
I1 H36 Harmonic Distortion%Read
I1 H37 Harmonic Distortion%Read
I1 H38 Harmonic Distortion%Read
I1 H39 Harmonic Distortion%Read
I1 H40 Harmonic Distortion%Read
I2 H01 Harmonic Distortion%Read
I2 H02 Harmonic Distortion%Read
I2 H03 Harmonic Distortion%Read
I2 H04 Harmonic Distortion%Read
I2 H05 Harmonic Distortion%Read
I2 H06 Harmonic Distortion%Read
I2 H07 Harmonic Distortion%Read
I2 H08 Harmonic Distortion%Read
I2 H09 Harmonic Distortion%Read
I2 H10 Harmonic Distortion%Read
I2 H11 Harmonic Distortion%Read
I2 H12 Harmonic Distortion%Read
I2 H13 Harmonic Distortion%Read
I2 H14 Harmonic Distortion%Read
I2 H15 Harmonic Distortion%Read
I2 H16 Harmonic Distortion%Read
I2 H17 Harmonic Distortion%Read
I2 H18 Harmonic Distortion%Read
I2 H19 Harmonic Distortion%Read
I2 H20 Harmonic Distortion%Read
I2 H21 Harmonic Distortion%Read
I2 H22 Harmonic Distortion%Read
I2 H23 Harmonic Distortion%Read
I2 H24 Harmonic Distortion%Read
I2 H25 Harmonic Distortion%Read
I2 H26 Harmonic Distortion%Read
I2 H27 Harmonic Distortion%Read
I2 H28 Harmonic Distortion%Read
I2 H29 Harmonic Distortion%Read
I2 H30 Harmonic Distortion%Read
I2 H31 Harmonic Distortion%Read
I2 H32 Harmonic Distortion%Read
I2 H33 Harmonic Distortion%Read
I2 H34 Harmonic Distortion%Read
I2 H35 Harmonic Distortion%Read
I2 H36 Harmonic Distortion%Read
I2 H37 Harmonic Distortion%Read
I2 H38 Harmonic Distortion%Read
I2 H39 Harmonic Distortion%Read
I2 H40 Harmonic Distortion%Read
I3 H01 Harmonic Distortion%Read
I3 H02 Harmonic Distortion%Read
I3 H03 Harmonic Distortion%Read
I3 H04 Harmonic Distortion%Read
I3 H05 Harmonic Distortion%Read
I3 H06 Harmonic Distortion%Read
I3 H07 Harmonic Distortion%Read
I3 H08 Harmonic Distortion%Read
I3 H09 Harmonic Distortion%Read
I3 H10 Harmonic Distortion%Read
I3 H11 Harmonic Distortion%Read
I3 H12 Harmonic Distortion%Read
I3 H13 Harmonic Distortion%Read
I3 H14 Harmonic Distortion%Read
I3 H15 Harmonic Distortion%Read
I3 H16 Harmonic Distortion%Read
I3 H17 Harmonic Distortion%Read
I3 H18 Harmonic Distortion%Read
I3 H19 Harmonic Distortion%Read
I3 H20 Harmonic Distortion%Read
I3 H21 Harmonic Distortion%Read
I3 H22 Harmonic Distortion%Read
I3 H23 Harmonic Distortion%Read
I3 H24 Harmonic Distortion%Read
I3 H25 Harmonic Distortion%Read
I3 H26 Harmonic Distortion%Read
I3 H27 Harmonic Distortion%Read
I3 H28 Harmonic Distortion%Read
I3 H29 Harmonic Distortion%Read
I3 H30 Harmonic Distortion%Read
I3 H31 Harmonic Distortion%Read
I3 H32 Harmonic Distortion%Read
I3 H33 Harmonic Distortion%Read
I3 H34 Harmonic Distortion%Read
I3 H35 Harmonic Distortion%Read
I3 H36 Harmonic Distortion%Read
I3 H37 Harmonic Distortion%Read
I3 H38 Harmonic Distortion%Read
I3 H39 Harmonic Distortion%Read
I3 H40 Harmonic Distortion%Read
Fundamental V1/V12 VoltageVRead
Fundamental V2/V23 VoltageVRead
Fundamental V3/V31 VoltageVRead
Fundamental I1 CurrentARead
Fundamental I2 CurrentARead
Fundamental I3 CurrentARead
Fundamental kW L1kWRead
Fundamental kW L2kWRead
Fundamental kW L3kWRead
Fundamental kvar L1kvarRead
Fundamental kvar L2kvarRead
Fundamental kvar L3kvarRead
Fundamental kVA L1kVARead
Fundamental kVA L2kVARead
Fundamental kVA L3kVARead
Fundamental Power Factor L1Read
Fundamental Power Factor L2Read
Fundamental Power Factor L3Read
Total Fundamental kWkWRead
Total Fundamental kvarkvarRead
Total Fundamental kVAkVARead
Total Fundamental PFRead
Min V1/V12 VoltageVRead
Min V2/V23 VoltageVRead
Min V3/V31 VoltageVRead
Min I1 CurrentARead
Min I2 CurrentARead
Min I3 CurrentARead
Min Total kWkWRead
Min Total kvarkvarRead
Min Total kVAkVARead
Min Total PFRead
Min In CurrentARead
Min FrequencyHzRead
Max V1/V12 VoltageVRead
Max V2/V23 VoltageVRead
Max V3/V31 VoltageVRead
Max I1 CurrentARead
Max I2 CurrentARead
Max I3 CurrentARead
Max Total kWkWRead
Max Total kvarkvarRead
Max Total kVAkVARead
Max Total PFRead
Max In CurrentARead
Max FrequencyHzRead
V1/V12 Maximum Volt DemandVRead
V2/V23 Maximum Volt DemandVRead
V3/V31 Maximum Volt DemandVRead
I1 Maximum Ampere DemandARead
I2 Maximum Ampere DemandARead
I3 Maximum Ampere DemandARead
Maximum kW Import Sliding Window DemandkWRead
Maximum kvar Import Sliding Window DemandkvarRead
Maximum kVA Sliding Window DemandkVARead
Maximum kW Export Sliding Window DemandkWRead
Maximum kvar Export Sliding Window DemandkvarRead
In Maximum Ampere DemandARead
Active TariffRead
Active ProfileRead
Analog Output AO1Read and write
Analog Output AO2Read and write
Analog Output AO3Read and write
Analog Output AO4Read and write
TOU Register 1 Tariff #1 RegisterkWhRead
TOU Register 1 Tariff #2 RegisterkWhRead
TOU Register 1 Tariff #3 RegisterkWhRead
TOU Register 1 Tariff #4 RegisterkWhRead
TOU Register 1 Tariff #5 RegisterkWhRead
TOU Register 1 Tariff #6 RegisterkWhRead
TOU Register 1 Tariff #7 RegisterkWhRead
TOU Register 1 Tariff #8 RegisterkWhRead
TOU Register 2 Tariff #1 RegisterkWhRead
TOU Register 2 Tariff #2 RegisterkWhRead
TOU Register 2 Tariff #3 RegisterkWhRead
TOU Register 2 Tariff #4 RegisterkWhRead
TOU Register 2 Tariff #5 RegisterkWhRead
TOU Register 2 Tariff #6 RegisterkWhRead
TOU Register 2 Tariff #7 RegisterkWhRead
TOU Register 2 Tariff #8 RegisterkWhRead
TOU Register 3 Tariff #1 RegisterkWhRead
TOU Register 3 Tariff #2 RegisterkWhRead
TOU Register 3 Tariff #3 RegisterkWhRead
TOU Register 3 Tariff #4 RegisterkWhRead
TOU Register 3 Tariff #5 RegisterkWhRead
TOU Register 3 Tariff #6 RegisterkWhRead
TOU Register 3 Tariff #7 RegisterkWhRead
TOU Register 3 Tariff #8 RegisterkWhRead
TOU Register 4 Tariff #1 RegisterkWhRead
TOU Register 4 Tariff #2 RegisterkWhRead
TOU Register 4 Tariff #3 RegisterkWhRead
TOU Register 4 Tariff #4 RegisterkWhRead
TOU Register 4 Tariff #5 RegisterkWhRead
TOU Register 4 Tariff #6 RegisterkWhRead
TOU Register 4 Tariff #7 RegisterkWhRead
TOU Register 4 Tariff #8 RegisterkWhRead
Accumulated Summary Register #1 DemandkWRead
Accumulated Summary Register #2 DemandkWRead
Accumulated Summary Register #3 DemandkWRead
Accumulated Summary Register #4 DemandkWRead
Block Summary Register #1 DemandkWRead
Block Summary Register #2 DemandkWRead
Block Summary Register #3 DemandkWRead
Block Summary Register #4 DemandkWRead
Sliding Window Summary Register #1 DemandkWRead
Sliding Window Summary Register #2 DemandkWRead
Sliding Window Summary Register #3 DemandkWRead
Sliding Window Summary Register #4 DemandkWRead
Summary Register #1 Maximum DemandkWRead
Summary Register #2 Maximum DemandkWRead
Summary Register #3 Maximum DemandkWRead
Summary Register #4 Maximum DemandkWRead
TOU Register 1 Tariff #1 Maximum DemandkWRead
TOU Register 1 Tariff #2 Maximum DemandkWRead
TOU Register 1 Tariff #3 Maximum DemandkWRead
TOU Register 1 Tariff #4 Maximum DemandkWRead
TOU Register 1 Tariff #5 Maximum DemandkWRead
TOU Register 1 Tariff #6 Maximum DemandkWRead
TOU Register 1 Tariff #7 Maximum DemandkWRead
TOU Register 1 Tariff #8 Maximum DemandkWRead
TOU Register 4 Tariff #1 Maximum DemandkWRead
TOU Register 4 Tariff #2 Maximum DemandkWRead
TOU Register 4 Tariff #3 Maximum DemandkWRead
TOU Register 4 Tariff #4 Maximum DemandkWRead
TOU Register 4 Tariff #5 Maximum DemandkWRead
TOU Register 4 Tariff #6 Maximum DemandkWRead
TOU Register 4 Tariff #7 Maximum DemandkWRead
TOU Register 4 Tariff #8 Maximum DemandkWRead
TOU Register 2 Tariff #1 Maximum DemandkWRead
TOU Register 2 Tariff #2 Maximum DemandkWRead
TOU Register 2 Tariff #3 Maximum DemandkWRead
TOU Register 2 Tariff #4 Maximum DemandkWRead
TOU Register 2 Tariff #5 Maximum DemandkWRead
TOU Register 2 Tariff #6 Maximum DemandkWRead
TOU Register 2 Tariff #7 Maximum DemandkWRead
TOU Register 2 Tariff #8 Maximum DemandkWRead
TOU Register 3 Tariff #1 Maximum DemandkWRead
TOU Register 3 Tariff #2 Maximum DemandkWRead
TOU Register 3 Tariff #3 Maximum DemandkWRead
TOU Register 3 Tariff #4 Maximum DemandkWRead
TOU Register 3 Tariff #5 Maximum DemandkWRead
TOU Register 3 Tariff #6 Maximum DemandkWRead
TOU Register 3 Tariff #7 Maximum DemandkWRead
TOU Register 3 Tariff #8 Maximum DemandkWRead
V1/V12 H01 Harmonic Angle°Read
V1/V12 H02 Harmonic Angle°Read
V1/V12 H03 Harmonic Angle°Read
V1/V12 H04 Harmonic Angle°Read
V1/V12 H05 Harmonic Angle°Read
V1/V12 H06 Harmonic Angle°Read
V1/V12 H07 Harmonic Angle°Read
V1/V12 H08 Harmonic Angle°Read
V1/V12 H09 Harmonic Angle°Read
V1/V12 H10 Harmonic Angle°Read
V1/V12 H11 Harmonic Angle°Read
V1/V12 H12 Harmonic Angle°Read
V1/V12 H13 Harmonic Angle°Read
V1/V12 H14 Harmonic Angle°Read
V1/V12 H15 Harmonic Angle°Read
V1/V12 H16 Harmonic Angle°Read
V1/V12 H17 Harmonic Angle°Read
V1/V12 H18 Harmonic Angle°Read
V1/V12 H19 Harmonic Angle°Read
V1/V12 H20 Harmonic Angle°Read
V1/V12 H21 Harmonic Angle°Read
V1/V12 H22 Harmonic Angle°Read
V1/V12 H23 Harmonic Angle°Read
V1/V12 H24 Harmonic Angle°Read
V1/V12 H25 Harmonic Angle°Read
V1/V12 H26 Harmonic Angle°Read
V1/V12 H27 Harmonic Angle°Read
V1/V12 H28 Harmonic Angle°Read
V1/V12 H29 Harmonic Angle°Read
V1/V12 H30 Harmonic Angle°Read
V1/V12 H31 Harmonic Angle°Read
V1/V12 H32 Harmonic Angle°Read
V1/V12 H33 Harmonic Angle°Read
V1/V12 H34 Harmonic Angle°Read
V1/V12 H35 Harmonic Angle°Read
V1/V12 H36 Harmonic Angle°Read
V1/V12 H37 Harmonic Angle°Read
V1/V12 H38 Harmonic Angle°Read
V1/V12 H39 Harmonic Angle°Read
V1/V12 H40 Harmonic Angle°Read
V2/V23 H01 Harmonic Angle°Read
V2/V23 H02 Harmonic Angle°Read
V2/V23 H03 Harmonic Angle°Read
V2/V23 H04 Harmonic Angle°Read
V2/V23 H05 Harmonic Angle°Read
V2/V23 H06 Harmonic Angle°Read
V2/V23 H07 Harmonic Angle°Read
V2/V23 H08 Harmonic Angle°Read
V2/V23 H09 Harmonic Angle°Read
V2/V23 H10 Harmonic Angle°Read
V2/V23 H11 Harmonic Angle°Read
V2/V23 H12 Harmonic Angle°Read
V2/V23 H13 Harmonic Angle°Read
V2/V23 H14 Harmonic Angle°Read
V2/V23 H15 Harmonic Angle°Read
V2/V23 H16 Harmonic Angle°Read
V2/V23 H17 Harmonic Angle°Read
V2/V23 H18 Harmonic Angle°Read
V2/V23 H19 Harmonic Angle°Read
V2/V23 H20 Harmonic Angle°Read
V2/V23 H21 Harmonic Angle°Read
V2/V23 H22 Harmonic Angle°Read
V2/V23 H23 Harmonic Angle°Read
V2/V23 H24 Harmonic Angle°Read
V2/V23 H25 Harmonic Angle°Read
V2/V23 H26 Harmonic Angle°Read
V2/V23 H27 Harmonic Angle°Read
V2/V23 H28 Harmonic Angle°Read
V2/V23 H29 Harmonic Angle°Read
V2/V23 H30 Harmonic Angle°Read
V2/V23 H31 Harmonic Angle°Read
V2/V23 H32 Harmonic Angle°Read
V2/V23 H33 Harmonic Angle°Read
V2/V23 H34 Harmonic Angle°Read
V2/V23 H35 Harmonic Angle°Read
V2/V23 H36 Harmonic Angle°Read
V2/V23 H37 Harmonic Angle°Read
V2/V23 H38 Harmonic Angle°Read
V2/V23 H39 Harmonic Angle°Read
V2/V23 H40 Harmonic Angle°Read
V1/V31 H01 Harmonic Angle°Read
V1/V31 H02 Harmonic Angle°Read
V1/V31 H03 Harmonic Angle°Read
V1/V31 H04 Harmonic Angle°Read
V1/V31 H05 Harmonic Angle°Read
V1/V31 H06 Harmonic Angle°Read
V1/V31 H07 Harmonic Angle°Read
V1/V31 H08 Harmonic Angle°Read
V1/V31 H09 Harmonic Angle°Read
V1/V31 H10 Harmonic Angle°Read
V1/V31 H11 Harmonic Angle°Read
V1/V31 H12 Harmonic Angle°Read
V1/V31 H13 Harmonic Angle°Read
V1/V31 H14 Harmonic Angle°Read
V1/V31 H15 Harmonic Angle°Read
V1/V31 H16 Harmonic Angle°Read
V1/V31 H17 Harmonic Angle°Read
V1/V31 H18 Harmonic Angle°Read
V1/V31 H19 Harmonic Angle°Read
V1/V31 H20 Harmonic Angle°Read
V1/V31 H21 Harmonic Angle°Read
V1/V31 H22 Harmonic Angle°Read
V1/V31 H23 Harmonic Angle°Read
V1/V31 H24 Harmonic Angle°Read
V1/V31 H25 Harmonic Angle°Read
V1/V31 H26 Harmonic Angle°Read
V1/V31 H27 Harmonic Angle°Read
V1/V31 H28 Harmonic Angle°Read
V1/V31 H29 Harmonic Angle°Read
V1/V31 H30 Harmonic Angle°Read
V1/V31 H31 Harmonic Angle°Read
V1/V31 H32 Harmonic Angle°Read
V1/V31 H33 Harmonic Angle°Read
V1/V31 H34 Harmonic Angle°Read
V1/V31 H35 Harmonic Angle°Read
V1/V31 H36 Harmonic Angle°Read
V1/V31 H37 Harmonic Angle°Read
V1/V31 H38 Harmonic Angle°Read
V1/V31 H39 Harmonic Angle°Read
V1/V31 H40 Harmonic Angle°Read
I1 H01 Harmonic Angle°Read
I1 H02 Harmonic Angle°Read
I1 H03 Harmonic Angle°Read
I1 H04 Harmonic Angle°Read
I1 H05 Harmonic Angle°Read
I1 H06 Harmonic Angle°Read
I1 H07 Harmonic Angle°Read
I1 H08 Harmonic Angle°Read
I1 H09 Harmonic Angle°Read
I1 H10 Harmonic Angle°Read
I1 H11 Harmonic Angle°Read
I1 H12 Harmonic Angle°Read
I1 H13 Harmonic Angle°Read
I1 H14 Harmonic Angle°Read
I1 H15 Harmonic Angle°Read
I1 H16 Harmonic Angle°Read
I1 H17 Harmonic Angle°Read
I1 H18 Harmonic Angle°Read
I1 H19 Harmonic Angle°Read
I1 H20 Harmonic Angle°Read
I1 H21 Harmonic Angle°Read
I1 H22 Harmonic Angle°Read
I1 H23 Harmonic Angle°Read
I1 H24 Harmonic Angle°Read
I1 H25 Harmonic Angle°Read
I1 H26 Harmonic Angle°Read
I1 H27 Harmonic Angle°Read
I1 H28 Harmonic Angle°Read
I1 H29 Harmonic Angle°Read
I1 H30 Harmonic Angle°Read
I1 H31 Harmonic Angle°Read
I1 H32 Harmonic Angle°Read
I1 H33 Harmonic Angle°Read
I1 H34 Harmonic Angle°Read
I1 H35 Harmonic Angle°Read
I1 H36 Harmonic Angle°Read
I1 H37 Harmonic Angle°Read
I1 H38 Harmonic Angle°Read
I1 H39 Harmonic Angle°Read
I1 H40 Harmonic Angle°Read
I2 H01 Harmonic Angle°Read
I2 H02 Harmonic Angle°Read
I2 H03 Harmonic Angle°Read
I2 H04 Harmonic Angle°Read
I2 H05 Harmonic Angle°Read
I2 H06 Harmonic Angle°Read
I2 H07 Harmonic Angle°Read
I2 H08 Harmonic Angle°Read
I2 H09 Harmonic Angle°Read
I2 H10 Harmonic Angle°Read
I2 H11 Harmonic Angle°Read
I2 H12 Harmonic Angle°Read
I2 H13 Harmonic Angle°Read
I2 H14 Harmonic Angle°Read
I2 H15 Harmonic Angle°Read
I2 H16 Harmonic Angle°Read
I2 H17 Harmonic Angle°Read
I2 H18 Harmonic Angle°Read
I2 H19 Harmonic Angle°Read
I2 H20 Harmonic Angle°Read
I2 H21 Harmonic Angle°Read
I2 H22 Harmonic Angle°Read
I2 H23 Harmonic Angle°Read
I2 H24 Harmonic Angle°Read
I2 H25 Harmonic Angle°Read
I2 H26 Harmonic Angle°Read
I2 H27 Harmonic Angle°Read
I2 H28 Harmonic Angle°Read
I2 H29 Harmonic Angle°Read
I2 H30 Harmonic Angle°Read
I2 H31 Harmonic Angle°Read
I2 H32 Harmonic Angle°Read
I2 H33 Harmonic Angle°Read
I2 H34 Harmonic Angle°Read
I2 H35 Harmonic Angle°Read
I2 H36 Harmonic Angle°Read
I2 H37 Harmonic Angle°Read
I2 H38 Harmonic Angle°Read
I2 H39 Harmonic Angle°Read
I2 H40 Harmonic Angle°Read
I3 H01 Harmonic Angle°Read
I3 H02 Harmonic Angle°Read
I3 H03 Harmonic Angle°Read
I3 H04 Harmonic Angle°Read
I3 H05 Harmonic Angle°Read
I3 H06 Harmonic Angle°Read
I3 H07 Harmonic Angle°Read
I3 H08 Harmonic Angle°Read
I3 H09 Harmonic Angle°Read
I3 H10 Harmonic Angle°Read
I3 H11 Harmonic Angle°Read
I3 H12 Harmonic Angle°Read
I3 H13 Harmonic Angle°Read
I3 H14 Harmonic Angle°Read
I3 H15 Harmonic Angle°Read
I3 H16 Harmonic Angle°Read
I3 H17 Harmonic Angle°Read
I3 H18 Harmonic Angle°Read
I3 H19 Harmonic Angle°Read
I3 H20 Harmonic Angle°Read
I3 H21 Harmonic Angle°Read
I3 H22 Harmonic Angle°Read
I3 H23 Harmonic Angle°Read
I3 H24 Harmonic Angle°Read
I3 H25 Harmonic Angle°Read
I3 H26 Harmonic Angle°Read
I3 H27 Harmonic Angle°Read
I3 H28 Harmonic Angle°Read
I3 H29 Harmonic Angle°Read
I3 H30 Harmonic Angle°Read
I3 H31 Harmonic Angle°Read
I3 H32 Harmonic Angle°Read
I3 H33 Harmonic Angle°Read
I3 H34 Harmonic Angle°Read
I3 H35 Harmonic Angle°Read
I3 H36 Harmonic Angle°Read
I3 H37 Harmonic Angle°Read
I3 H38 Harmonic Angle°Read
I3 H39 Harmonic Angle°Read
I3 H40 Harmonic Angle°Read
Setpoint StatusRead
Assignable Register 0Read and write
Assignable Register 1Read and write
Assignable Register 2Read and write
Assignable Register 3Read and write
Assignable Register 4Read and write
Assignable Register 5Read and write
Assignable Register 6Read and write
Assignable Register 7Read and write
Assignable Register 8Read and write
Assignable Register 9Read and write
Assignable Register 10Read and write
Assignable Register 11Read and write
Assignable Register 12Read and write
Assignable Register 13Read and write
Assignable Register 14Read and write
Assignable Register 15Read and write
Assignable Register 16Read and write
Assignable Register 17Read and write
Assignable Register 18Read and write
Assignable Register 19Read and write
Assignable Register 20Read and write
Assignable Register 21Read and write
Assignable Register 22Read and write
Assignable Register 23Read and write
Assignable Register 24Read and write
Assignable Register 25Read and write
Assignable Register 26Read and write
Assignable Register 27Read and write
Assignable Register 28Read and write
Assignable Register 29Read and write
Assignable Register 30Read and write
Assignable Register 31Read and write
Assignable Register 32Read and write
Assignable Register 33Read and write
Assignable Register 34Read and write
Assignable Register 35Read and write
Assignable Register 36Read and write
Assignable Register 37Read and write
Assignable Register 38Read and write
Assignable Register 39Read and write
Assignable Register 40Read and write
Assignable Register 41Read and write
Assignable Register 42Read and write
Assignable Register 43Read and write
Assignable Register 44Read and write
Assignable Register 45Read and write
Assignable Register 46Read and write
Assignable Register 47Read and write
Assignable Register 48Read and write
Assignable Register 49Read and write
Assignable Register 50Read and write
Assignable Register 51Read and write
Assignable Register 52Read and write
Assignable Register 53Read and write
Assignable Register 54Read and write
Assignable Register 55Read and write
Assignable Register 56Read and write
Assignable Register 57Read and write
Assignable Register 58Read and write
Assignable Register 59Read and write
Assignable Register 60Read and write
Assignable Register 61Read and write
Assignable Register 62Read and write
Assignable Register 63Read and write
Assignable Register 64Read and write
Assignable Register 65Read and write
Assignable Register 66Read and write
Assignable Register 67Read and write
Assignable Register 68Read and write
Assignable Register 69Read and write
Assignable Register 70Read and write
Assignable Register 71Read and write
Assignable Register 72Read and write
Assignable Register 73Read and write
Assignable Register 74Read and write
Assignable Register 75Read and write
Assignable Register 76Read and write
Assignable Register 77Read and write
Assignable Register 78Read and write
Assignable Register 79Read and write
Assignable Register 80Read and write
Assignable Register 81Read and write
Assignable Register 82Read and write
Assignable Register 83Read and write
Assignable Register 84Read and write
Assignable Register 85Read and write
Assignable Register 86Read and write
Assignable Register 87Read and write
Assignable Register 88Read and write
Assignable Register 89Read and write
Assignable Register 90Read and write
Assignable Register 91Read and write
Assignable Register 92Read and write
Assignable Register 93Read and write
Assignable Register 94Read and write
Assignable Register 95Read and write
Assignable Register 96Read and write
Assignable Register 97Read and write
Assignable Register 98Read and write
Assignable Register 99Read and write
Assignable Register 100Read and write
Assignable Register 101Read and write
Assignable Register 102Read and write
Assignable Register 103Read and write
Assignable Register 104Read and write
Assignable Register 105Read and write
Assignable Register 106Read and write
Assignable Register 107Read and write
Assignable Register 108Read and write
Assignable Register 109Read and write
Assignable Register 110Read and write
Assignable Register 111Read and write
Assignable Register 112Read and write
Assignable Register 113Read and write
Assignable Register 114Read and write
Assignable Register 115Read and write
Assignable Register 116Read and write
Assignable Register 117Read and write
Assignable Register 118Read and write
Assignable Register 119Read and write
Assignable Map Address 0Read and write
Assignable Map Address 1Read and write
Assignable Map Address 2Read and write
Assignable Map Address 3Read and write
Assignable Map Address 4Read and write
Assignable Map Address 5Read and write
Assignable Map Address 6Read and write
Assignable Map Address 7Read and write
Assignable Map Address 8Read and write
Assignable Map Address 9Read and write
Assignable Map Address 10Read and write
Assignable Map Address 11Read and write
Assignable Map Address 12Read and write
Assignable Map Address 13Read and write
Assignable Map Address 14Read and write
Assignable Map Address 15Read and write
Assignable Map Address 16Read and write
Assignable Map Address 17Read and write
Assignable Map Address 18Read and write
Assignable Map Address 19Read and write
Assignable Map Address 20Read and write
Assignable Map Address 21Read and write
Assignable Map Address 22Read and write
Assignable Map Address 23Read and write
Assignable Map Address 24Read and write
Assignable Map Address 25Read and write
Assignable Map Address 26Read and write
Assignable Map Address 27Read and write
Assignable Map Address 28Read and write
Assignable Map Address 29Read and write
Assignable Map Address 30Read and write
Assignable Map Address 31Read and write
Assignable Map Address 32Read and write
Assignable Map Address 33Read and write
Assignable Map Address 34Read and write
Assignable Map Address 35Read and write
Assignable Map Address 36Read and write
Assignable Map Address 37Read and write
Assignable Map Address 38Read and write
Assignable Map Address 39Read and write
Assignable Map Address 40Read and write
Assignable Map Address 41Read and write
Assignable Map Address 42Read and write
Assignable Map Address 43Read and write
Assignable Map Address 44Read and write
Assignable Map Address 45Read and write
Assignable Map Address 46Read and write
Assignable Map Address 47Read and write
Assignable Map Address 48Read and write
Assignable Map Address 49Read and write
Assignable Map Address 50Read and write
Assignable Map Address 51Read and write
Assignable Map Address 52Read and write
Assignable Map Address 53Read and write
Assignable Map Address 54Read and write
Assignable Map Address 55Read and write
Assignable Map Address 56Read and write
Assignable Map Address 57Read and write
Assignable Map Address 58Read and write
Assignable Map Address 59Read and write
Assignable Map Address 60Read and write
Assignable Map Address 61Read and write
Assignable Map Address 62Read and write
Assignable Map Address 63Read and write
Assignable Map Address 64Read and write
Assignable Map Address 65Read and write
Assignable Map Address 66Read and write
Assignable Map Address 67Read and write
Assignable Map Address 68Read and write
Assignable Map Address 69Read and write
Assignable Map Address 70Read and write
Assignable Map Address 71Read and write
Assignable Map Address 72Read and write
Assignable Map Address 73Read and write
Assignable Map Address 74Read and write
Assignable Map Address 75Read and write
Assignable Map Address 76Read and write
Assignable Map Address 77Read and write
Assignable Map Address 78Read and write
Assignable Map Address 79Read and write
Assignable Map Address 80Read and write
Assignable Map Address 81Read and write
Assignable Map Address 82Read and write
Assignable Map Address 83Read and write
Assignable Map Address 84Read and write
Assignable Map Address 85Read and write
Assignable Map Address 86Read and write
Assignable Map Address 87Read and write
Assignable Map Address 88Read and write
Assignable Map Address 89Read and write
Assignable Map Address 90Read and write
Assignable Map Address 91Read and write
Assignable Map Address 92Read and write
Assignable Map Address 93Read and write
Assignable Map Address 94Read and write
Assignable Map Address 95Read and write
Assignable Map Address 96Read and write
Assignable Map Address 97Read and write
Assignable Map Address 98Read and write
Assignable Map Address 99Read and write
Assignable Map Address 100Read and write
Assignable Map Address 101Read and write
Assignable Map Address 102Read and write
Assignable Map Address 103Read and write
Assignable Map Address 104Read and write
Assignable Map Address 105Read and write
Assignable Map Address 106Read and write
Assignable Map Address 107Read and write
Assignable Map Address 108Read and write
Assignable Map Address 109Read and write
Assignable Map Address 110Read and write
Assignable Map Address 111Read and write
Assignable Map Address 112Read and write
Assignable Map Address 113Read and write
Assignable Map Address 114Read and write
Assignable Map Address 115Read and write
Assignable Map Address 116Read and write
Assignable Map Address 117Read and write
Assignable Map Address 118Read and write
Assignable Map Address 119Read and write
Low Raw ScaleRead
High Raw ScaleRead
Voltage ScaleVRead and write
Current ScaleARead and write
Type of 32-bit RegistersRead and write

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Use cases

  • Show voltage, current, power and power factor per phase on a dashboard for each feeder.
  • Log imported energy per phase and per tariff to report consumption month by month.
  • Get an alert when voltage THD or current unbalance passes a limit you choose.
  • Watch the maximum kW and kVA demand to see when a connection nears its contracted capacity.
  • Check the digital inputs and relay outputs of the meter in ModbusCloud next to the readings.

Installation

  1. Connect the RS485 terminals of COM1 to the RS485 port of the ModbusCloud Gateway, A to A and B to B, with a terminator at both ends of the bus.

  2. On the meter, open the communication setup for COM1 and set Modbus RTU, an address, the baud rate and the data format.

  3. In ModbusCloud, add a Modbus device with the same address, speed and parity and import this template.

  4. Check that frequency reads about 50 Hz and that the voltages match the display of the meter.

  5. If you need finer resolution, switch the meter to high resolution and adjust the scale of the affected values.

Things to watch for

The meter does not answer on the bus. What should I check?

Check that COM1 is set to Modbus RTU and not to SATEC ASCII or DNP3, and that address, baud rate and data format match ModbusCloud. Then swap A and B and check the terminator at both ends of the line.

Why do voltages and power show only whole numbers?

The meter ships in low resolution: whole volts, amps and kW. In high resolution volts get one decimal and power is in W when the PT ratio is 1. If you change it, adjust the scale of those values in ModbusCloud.

Energy and harmonics stay at zero. Is that a fault?

No. Energy, demand and tariff values only exist in the PM130E and PM130EH, harmonics only in the PM130EH. The PM130P returns zero for those registers.

Can I write registers from ModbusCloud?

Yes, the pulse counters, analog outputs, voltage and current scale and the assignable register map are writable. Changing the scale or the 32-bit register type changes how all readings are interpreted, so leave them at the default unless you know why. Writing must be enabled for the gateway first.

Want to see how it works?