Senmatic Senmatic AMI Penta System Modbus TCP template

Senmatic AMI Penta System

Fertigation mixer for greenhouses: EC, pH, flow, pumps, alarms and mixer settings.

The Senmatic AMI Penta is a fertilizer mixer and irrigation controller that doses fertilizer and acid into the irrigation water of greenhouses and nurseries. This Modbus TCP template reads EC, pH, flow, pressure, mixer state and alarms from unit ID 0 and lets you write standby commands, alarm limits and controller settings from ModbusCloud.

Protocol
Modbus TCP
Connection
Ethernet, Modbus TCP
Registers
1329, read and write
Key readings
EC1 and EC2 · pH1 and pH2 · Irrigation water flow · Irrigation volume · Water pressure · Mixer state · Alarm status
Available commands
Standby and cancel irrigation · EC and pH alarm limits · EC and pH controller settings · Sensor calibration · Pump settings
Compatible models
AMI Penta
Last updated

Registers (1329)

1329 read, 520 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
EC1 ValueRead288FC03float32
EC2 ValueRead290FC03float32
pH1 ValueRead318FC03float32
pH2 ValueRead320FC03float32
EC1 Value AvgRead282FC03float32
EC2 Value AvgRead
pH1 Value AvgRead
pH2 Value AvgRead
Flow 1Read
Fresh Water FlowRead
Flow 3Read
Flow VolumeRead
Basin FlowRead
Actual PressureRead
Actual Pressure 2Read
Temperature Analog AdjustedRead
Humidity Analog AdjustedRead
System StateRead
Mixer Active RecipeRead
Mixer Active Group NoRead
Mixer EC Final DemandRead
Mixer pH Final DemandRead
Mixer Flow DemandRead
Time Last RunRead
Volume Last RunRead
Stop AlarmRead
Final Alarm StatusRead
EC Alarm BitmaskRead
pH Alarm BitmaskRead
Other Alarm BitmaskRead
Alarms Sensor Failure BitmaskRead
Alarm Relay ActiveRead
Temperature Analog DirectRead
Humidity Analog DirectRead
Sensor 7 Analog AdjustedRead
Sensor 7 Analog DirectRead
Sensor 7 Direct InRead
EC1 Direct InRead
EC2 Direct InRead
EC1 Sensor FailureRead
EC2 Sensor FailureRead
pH1 Direct InRead
pH2 Direct InRead
pH1 Sensor FailureRead
pH2 Sensor FailureRead
Nominal FlowRead
Flow 1 FreqRead
Flow Sensor 2 FreqRead
Flow 3 FreqRead
Flow Sensor 1 ActualRead
Flow Sensor 2 ActualRead
UV Prestart ElapsedRead
Analog Start 0 ValueRead
Analog Start 1 ValueRead
Analog Start 2 ValueRead
Geo Time Day Change PulseRead
Geo Time SunsetsRead
Geo Time SunrisesRead
Geo Time Sunset HourshRead
Geo Time Sunrise HourshRead
Geo Time Sun AzimuthRead
Geo Time Sun AltitudeRead
Start Filter CleanRead
Mixer Supply Water RequestRead
Mixer Startup Alarm EnabledRead
Mixer Final Irrigation RequestRead
All Enable Mixer 1Read
Mixer EC ErrorRead
Mixer NOT Tank EmptyingRead
Mixer Active BasinRead
Mixer Enable Fertilizer DosingRead
Mixer Fresh Water Dosing AllowedRead
Pump 2 EnableRead
Mixer Irrigation Water ReadyRead
Pressure Pump 1 ActiveRead
Pressure Pump 2 ActiveRead
Supply Pump ActiveRead
Tank EmptyingRead
Mixer EC Dosing EnableRead
Mixer pH Dosing EnableRead
Mixer Water AcknowledgeRead
Mixer Delayed Tank Level Top Is HighRead
Mixer NOT Boom Post RinseRead
Mixer Supply Valve EnableRead
UV Active TimesRead
Switch Time UV StartsRead
Switch Time UV StopsRead
Mixer pH ErrorRead
Mixer Fresh Water Pct Demand%Read
Basin Level 1 LowRead
Filter Clean StateRead
Filter Clean Active Pump TimesRead
Old Filter Clean ActiveRead
Filter Clean Old Clean TimerRead
Filter Clean Old Pause TimerRead
Filter Clean Timer Switch TimesRead
Filter Clean Pause Timer Switch TimesRead
Filter Clean TimerRead
Filter Clean Pause TimerRead
Filter Clean Next FlagRead
Mixer EC Basic DemandRead
Mixer EC Sun Correction FactorRead
Mixer EC Final Demand Pre Sun CorrectionRead
Mixer EC Return CompensationRead
Mixer pH Return CompensationRead
Mixer pH Basic DemandRead
Mixer pH Normalized Error AvgRead
Mixer Initial Duty Cycle ECRead
Mixer P Duty Cycle ContribRead
Mixer I Duty Cycle ContribRead
Mixer D Duty Cycle ContribRead
Mixer pH Duty CycleRead
Mixer pH Final P FactorRead
Mixer pH Calc Init Duty CycleRead
Mixer P Contrib Duty Cycle pHRead
Mixer I Contrib Duty Cycle pHRead
Mixer D Contrib Duty Cycle pHRead
Mixer EC Duty CycleRead
Mixer Dosing Time Fert AsRead
Mixer Dosing Time Fert BsRead
Mixer Dosing Time Fert CsRead
Mixer Dosing Time Fert DsRead
Mixer Dosing Time Fert EsRead
Mixer Dosing Time Fert FsRead
Mixer Dosing Time Fert GsRead
Mixer Dosing Time Fert HsRead
Mixer Active Recipe 2Read
Mixer pH Stop DosingRead
Pumps Pressure DemandRead
Pumps Pressure ErrorRead
Pump 2 ActiveRead
Pump 2 SpeedRead
Pumps IdemandRead
Pump 2 Speed DemRead
Pump 1 Speed DemRead
Elapsed Valve Delay TimesRead
Elapsed Post Rinse TimesRead
Mixer Active pH TypeRead
Geo Time Week Changed PulseRead
EC1 VoltVRead
EC2 VoltVRead
pH1 VoltVRead
pH2 VoltVRead
EC1 Volt ErrorVRead
EC2 Volt ErrorVRead
pH1 Volt ErrorVRead
pH2 Volt ErrorVRead
EC1 Short Avg ValueRead
EC2 Short Avg ValueRead
pH1 Short Avg ValueRead
pH2 Short Avg ValueRead
UV Light ActiveRead
Supply Pump Remaining Stop DelaysRead
Main Pump Remaining Stop DelaysRead
UV Pre Start Time LeftsRead
UV Stop Delay Time LeftsRead
Stopped By Low Basin LevelRead
Mixer Suppress RegulatorRead
Water Supply Mixing Valve On TimesRead
Water Supply Mixing Valve Off TimesRead
Water Supply Mixing Valve ModeRead
Water Supply Fresh Water Flow ErrorRead
Hose Irrigation WaitingRead
Hose Irrigation Time LeftsRead
Basin Flow Demand AutoRead
Flow Fresh Water Demand AutoRead
Pressure Direct InRead
Basin Level 0Read
Basin Level 1Read
Basin Level 2Read
Basin Level 3Read
Basin Level 4Read
Basin Level 5Read
Basin Level 6Read
Basin Level 7Read
Mixer Pre Start Delay ElapsedRead
Mixer Pre Start Delay LeftsRead
Mixer Active Basin Level 1Read
Pumps PcontribRead
Basins 0 Water HeightRead
Basins 1 Water HeightRead
Basins 2 Water HeightRead
Basins 3 Water HeightRead
Basins 4 Water HeightRead
Basins 5 Water HeightRead
Basins 6 Water HeightRead
Basins 7 Water HeightRead
Mixer Drain Pulse Counter 0Read
Mixer Drain Pulse Counter 1Read
Mixer Drain Pulse Counter 2Read
Mixer Drain Pulse Counter 3Read
Mixer Drain Pulse Counter 4Read
Mixer Drain Pulse Counter 5Read
Mixer Drain Pulse Counter 6Read
Mixer Drain Pulse Counter 7Read
Analog 0 Direct InRead
Analog 1 Direct InRead
Analog 2 Direct InRead
Analog 3 Direct InRead
Analog 4 Direct InRead
Analog 5 Direct InRead
Analog 6 Direct InRead
Analog 7 Direct InRead
Analog 0 CurrentRead
Analog 1 CurrentRead
Analog 2 CurrentRead
Analog 3 CurrentRead
Analog 4 CurrentRead
Analog 5 CurrentRead
Analog 6 CurrentRead
Analog 7 CurrentRead
Analog 0 VoltageVRead
Analog 1 VoltageVRead
Analog 2 VoltageVRead
Analog 3 VoltageVRead
Analog 4 VoltageVRead
Analog 5 VoltageVRead
Analog 6 VoltageVRead
Analog 7 VoltageVRead
Analog 0 ValueRead
Analog 1 ValueRead
Analog 2 ValueRead
Analog 3 ValueRead
Analog 4 ValueRead
Analog 5 ValueRead
Analog 6 ValueRead
Analog 7 ValueRead
Sensors StructureRead
Elapsed S Pump Pre Start TimesRead
Pre Start ActiveRead
Mixer Group Start SignalRead
Hose Irrigation Hose Period ActiveRead
Filter Clean Time At Last RunRead
Pump 1 Output RpmrpmRead
Pump 2 Output RpmrpmRead
Mixer Active Valves In ParallelRead
Mixer Acc Dosing Time Fert AsRead
Mixer Acc Dosing Time Fert BsRead
Mixer Acc Dosing Time Fert CsRead
Mixer Acc Dosing Time Fert DsRead
Mixer Acc Dosing Time Fert EsRead
Mixer Acc Dosing Time Fert FsRead
Mixer Acc Dosing Time Fert GsRead
Mixer Acc Dosing Time Fert HsRead
Mixer Final Dosing Time Fert AsRead
Mixer Final Dosing Time Fert BsRead
Mixer Final Dosing Time Fert CsRead
Mixer Final Dosing Time Fert DsRead
Mixer Final Dosing Time Fert EsRead
Mixer Final Dosing Time Fert FsRead
Mixer Final Dosing Time Fert GsRead
Mixer Final Dosing Time Fert HsRead
Mixer PID Duty CycleRead
Mixer pH Initiator ActiveRead
Water Supply Double Mixing InstalledRead
Local WT Bar Pressure Direct InRead
Local WT Bar Pressure DirectRead
Local WT Bar Pressure Direct AvgRead
Local WT Bar Pressure FailureRead
Local WT Bar Pressure VoltageVRead
Local WT Light Intensity Direct InRead
Local WT Light Intensity DirectRead
Local WT Light Intensity Direct AvgRead
Local WT Light Intensity Sensor FailureRead
Local WT Light Intensity VoltageVRead
Local WT Outdoor Humidity Direct InRead
Local WT Outdoor Humidity DirectRead
Local WT Outdoor Humidity Direct AvgRead
Local WT Outdoor Humidity Sensor FailureRead
Local WT Outdoor Humidity VoltageVRead
Local WT Rain Direct Analog InRead
Local WT Rain Direct Digital InRead
Local WT RainRead
Local WT Snow Direct InRead
Local WT SnowRead
Local WT Sun Radiation Direct InRead
Local WT Sun Radiation DirectRead
Local WT Sun Radiation Direct AvgRead
Local WT Sun Radiation Sensor FailureRead
Local WT Sun Radiation VoltageVRead
Local WT Temperature Direct InRead
Local WT Temperature DirectRead
Local WT Temperature Direct AvgRead
Local WT Temperature Sensor FailureRead
Local WT Wind Direction Direct InRead
Local WT Wind Direction DirectRead
Local WT Wind Direction Direct AvgRead
Local WT Wind Direction Sensor FailureRead
Local WT Wind Direction VoltageVRead
Local WT Wind Speed DigitalRead
Local WT Wind Speed Direct Analog InRead
Local WT Wind Speed Direct Digital InRead
Local WT Wind Speed DirectRead
Local WT Wind Speed Direct AvgRead
Local WT Wind Speed Sensor FailureRead
Local WT Wind Speed VoltageVRead
Local WT Temperature VoltageVRead
Rain Gauge PulseRead
Rain Gauge Yesterday PulsesRead
Rain Gauge Daily PulsesRead
Rain Gauge Weekly PulsesRead
Rain Gauge Last HourRead
Rain Gauge TodayRead
Rain Gauge YesterdayRead
Rain Gauge WeekRead
Mixer Activity Active 0 Valve NoRead
Mixer Activity Active 0 Valve TimesRead
Mixer Activity Active 0 Elapsed TimesRead
Mixer Activity Active 1 Valve NoRead
Mixer Activity Active 1 Valve TimesRead
Mixer Activity Active 1 Elapsed TimesRead
Mixer Activity Active 2 Valve NoRead
Mixer Activity Active 2 Valve TimesRead
Mixer Activity Active 2 Elapsed TimesRead
Mixer Activity Active 3 Valve NoRead
Mixer Activity Active 3 Valve TimesRead
Mixer Activity Active 3 Elapsed TimesRead
Mixer Activity Active 4 Valve NoRead
Mixer Activity Active 4 Valve TimesRead
Mixer Activity Active 4 Elapsed TimesRead
Mixer Activity Active 5 Valve NoRead
Mixer Activity Active 5 Valve TimesRead
Mixer Activity Active 5 Elapsed TimesRead
Mixer Activity Next 0 Valve NoRead
Mixer Activity Next 1 Valve NoRead
Mixer Activity Next 2 Valve NoRead
Mixer Activity Next 3 Valve NoRead
Mixer Activity Next 4 Valve NoRead
Mixer Activity Next 5 Valve NoRead
Mixer Activity Next 6 Valve NoRead
Mixer Activity Next 0 Valve TimesRead
Mixer Activity Next 1 Valve TimesRead
Mixer Activity Next 2 Valve TimesRead
Mixer Activity Next 3 Valve TimesRead
Mixer Activity Next 4 Valve TimesRead
Mixer Activity Next 5 Valve TimesRead
Mixer Activity Next 6 Valve TimesRead
Mixer Activity Next 0 EnabledRead
Mixer Activity Next 1 EnabledRead
Mixer Activity Next 2 EnabledRead
Mixer Activity Next 3 EnabledRead
Mixer Activity Next 4 EnabledRead
Mixer Activity Next 5 EnabledRead
Mixer Activity Next 6 EnabledRead
Mixer Activity Active 0 EnabledRead
Mixer Activity Active 1 EnabledRead
Mixer Activity Active 2 EnabledRead
Mixer Activity Active 3 EnabledRead
Mixer Activity Active 4 EnabledRead
Mixer Activity Active 5 EnabledRead
Mixer Start Condition NumberRead
Mixer Activity Basin ExistRead
Mixer Activity Basin Pump ActiveRead
Mixer Active Mixing ModeRead
Mixer Master ValveRead
Mixer Activity Stop AlarmRead
Mixer Activity EC Stop AlarmRead
Mixer Activity pH Stop AlarmRead
Mixer Activity Delay IDRead
Mixer Activity Delay Remaining TimesRead
Mixer Activity Active 0 Valve VolumeRead
Mixer Activity Active 1 Valve VolumeRead
Mixer Activity Active 2 Valve VolumeRead
Mixer Activity Active 3 Valve VolumeRead
Mixer Activity Active 4 Valve VolumeRead
Mixer Activity Active 5 Valve VolumeRead
Mixer Activity Active 0 Elapsed VolumeRead
Mixer Activity Active 1 Elapsed VolumeRead
Mixer Activity Active 2 Elapsed VolumeRead
Mixer Activity Active 3 Elapsed VolumeRead
Mixer Activity Active 4 Elapsed VolumeRead
Mixer Activity Active 5 Elapsed VolumeRead
Mixer Activity Is VolumeRead
Mixer Activity Next 0 Valve VolumeRead
Mixer Activity Next 1 Valve VolumeRead
Mixer Activity Next 2 Valve VolumeRead
Mixer Activity Next 3 Valve VolumeRead
Mixer Activity Next 4 Valve VolumeRead
Mixer Activity Next 5 Valve VolumeRead
Mixer Activity Next 6 Valve VolumeRead
Mixer Bio Fertilizer 0 Sensor DirectRead
Mixer Bio Fertilizer 1 Sensor DirectRead
Mixer Bio Fertilizer 2 Sensor DirectRead
Mixer Bio Fertilizer 3 Sensor DirectRead
Mixer Bio Fertilizer 4 Sensor DirectRead
Mixer Bio Fertilizer 5 Sensor DirectRead
Mixer Bio Fertilizer 6 Sensor DirectRead
Mixer Bio Fertilizer 7 Sensor DirectRead
Mixer Fertilizer 0 Bio FlowRead
Mixer Fertilizer 1 Bio FlowRead
Mixer Fertilizer 2 Bio FlowRead
Mixer Fertilizer 3 Bio FlowRead
Mixer Fertilizer 4 Bio FlowRead
Mixer Fertilizer 5 Bio FlowRead
Mixer Fertilizer 6 Bio FlowRead
Mixer Fertilizer 7 Bio FlowRead
Mixer Fertilizer 0 Bio Flow AvgRead
Mixer Fertilizer 1 Bio Flow AvgRead
Mixer Fertilizer 2 Bio Flow AvgRead
Mixer Fertilizer 3 Bio Flow AvgRead
Mixer Fertilizer 4 Bio Flow AvgRead
Mixer Fertilizer 5 Bio Flow AvgRead
Mixer Fertilizer 6 Bio Flow AvgRead
Mixer Fertilizer 7 Bio Flow AvgRead
Mixer Fertilizer 0 Bio Flow DemandRead
Mixer Fertilizer 1 Bio Flow DemandRead
Mixer Fertilizer 2 Bio Flow DemandRead
Mixer Fertilizer 3 Bio Flow DemandRead
Mixer Fertilizer 4 Bio Flow DemandRead
Mixer Fertilizer 5 Bio Flow DemandRead
Mixer Fertilizer 6 Bio Flow DemandRead
Mixer Fertilizer 7 Bio Flow DemandRead
Mixer Bio Fertilizer 0 ErrorRead
Mixer Bio Fertilizer 1 ErrorRead
Mixer Bio Fertilizer 2 ErrorRead
Mixer Bio Fertilizer 3 ErrorRead
Mixer Bio Fertilizer 4 ErrorRead
Mixer Bio Fertilizer 5 ErrorRead
Mixer Bio Fertilizer 6 ErrorRead
Mixer Bio Fertilizer 7 ErrorRead
Mixer Bio Fertilizer 0 PtermRead
Mixer Bio Fertilizer 1 PtermRead
Mixer Bio Fertilizer 2 PtermRead
Mixer Bio Fertilizer 3 PtermRead
Mixer Bio Fertilizer 4 PtermRead
Mixer Bio Fertilizer 5 PtermRead
Mixer Bio Fertilizer 6 PtermRead
Mixer Bio Fertilizer 7 PtermRead
Mixer Bio Fertilizer 0 ItermRead
Mixer Bio Fertilizer 1 ItermRead
Mixer Bio Fertilizer 2 ItermRead
Mixer Bio Fertilizer 3 ItermRead
Mixer Bio Fertilizer 4 ItermRead
Mixer Bio Fertilizer 5 ItermRead
Mixer Bio Fertilizer 6 ItermRead
Mixer Bio Fertilizer 7 ItermRead
Mixer Bio Fertilizer 0 DtermRead
Mixer Bio Fertilizer 1 DtermRead
Mixer Bio Fertilizer 2 DtermRead
Mixer Bio Fertilizer 3 DtermRead
Mixer Bio Fertilizer 4 DtermRead
Mixer Bio Fertilizer 5 DtermRead
Mixer Bio Fertilizer 6 DtermRead
Mixer Bio Fertilizer 7 DtermRead
Mixer Bio Fertilizer 0 Duty CycleRead
Mixer Bio Fertilizer 1 Duty CycleRead
Mixer Bio Fertilizer 2 Duty CycleRead
Mixer Bio Fertilizer 3 Duty CycleRead
Mixer Bio Fertilizer 4 Duty CycleRead
Mixer Bio Fertilizer 5 Duty CycleRead
Mixer Bio Fertilizer 6 Duty CycleRead
Mixer Bio Fertilizer 7 Duty CycleRead
Mixer Bio Fertilizer 0 Analog OutRead
Mixer Bio Fertilizer 1 Analog OutRead
Mixer Bio Fertilizer 2 Analog OutRead
Mixer Bio Fertilizer 3 Analog OutRead
Mixer Bio Fertilizer 4 Analog OutRead
Mixer Bio Fertilizer 5 Analog OutRead
Mixer Bio Fertilizer 6 Analog OutRead
Mixer Bio Fertilizer 7 Analog OutRead
Mixer Bio Fertilizer 0 Output VoltageVRead
Mixer Bio Fertilizer 1 Output VoltageVRead
Mixer Bio Fertilizer 2 Output VoltageVRead
Mixer Bio Fertilizer 3 Output VoltageVRead
Mixer Bio Fertilizer 4 Output VoltageVRead
Mixer Bio Fertilizer 5 Output VoltageVRead
Mixer Bio Fertilizer 6 Output VoltageVRead
Mixer Bio Fertilizer 7 Output VoltageVRead
Pressure Direct In 2Read
Pump 1 Speed OutputRead
Pump 2 Speed OutputRead
Press Pump 1 Active TimeRead
Press Pump 2 Active TimeRead
Pumps Time At Last RunRead
Pump 2 As PrimaryRead
Press Pump 1 Active HourshRead
Press Pump 2 Active HourshRead
Mixer Initial Duty Cycle EC Fert ARead
Mixer Duty Cycle Fert ARead
Alarms Tank Low Level Post Wait ActiveRead
Tank Old Low Level AlarmRead
Low Level Tank AlarmRead
Latched Low Level Tank AlarmRead
EC1 Absolute Low AlarmRead
EC1 Absolute High AlarmRead
EC1 Relative Low AlarmRead
EC1 Relative High AlarmRead
pH1 Absolute Low AlarmRead
pH1 Absolute High AlarmRead
pH1 Relative Low AlarmRead
pH1 Relative High AlarmRead
EC2 Absolute Low Alarm StatusRead
EC2 Absolute High Alarm StatusRead
pH2 Absolute Low Alarm StatusRead
pH2 Absolute High Alarm StatusRead
EC1 EC2 Deviation AlarmRead
pH1 pH2 Deviation AlarmRead
Valve Flow Alarm FinalRead
Valve Flow Group Flow AlarmRead
Mixer Flow AlarmRead
Valve Flow Pump AlarmRead
Valve Flow Fertilizer Level AlarmsRead
Valve Flow Fertilizer Dosing AlarmRead
Valve Flow Valve AlarmsRead
Valve Flow Irrigation Boom AlarmRead
Max Flow Alarm When ActiveRead
Max Flow Alarm Not ActiveRead
Alarm Bell ResetRead
Alarms Bell Start TimesRead
Flow Alarm Valve NoRead
Alarms VLT1 Module OKRead
Alarms VLT1 Fault DetectionRead
Alarms VLT2 Module OKRead
Alarms VLT2 Fault DetectionRead
VLT1 Pump AlarmRead
VLT2 Pump AlarmRead
VLT1 Idle AlarmRead
VLT2 Idle AlarmRead
Alarms VLT1 Ready To Switch OnRead
Flow Alarm Valve No Pos 2Read
Flow Alarm Valve No Pos 3Read
Flow Alarm Valve No Pos 4Read
Alarms VLT2 Ready To Switch OnRead
Alarms EC1 Absolute High LimitRead
Alarms EC1 Absolute Low LimitRead
Alarms EC1 Relative High LimitRead
Alarms EC1 Relative Low LimitRead
Alarms pH1 Absolute High LimitRead
Alarms pH1 Absolute Low LimitRead
Alarms pH1 Relative High LimitRead
Alarms pH1 Relative Low LimitRead
Alarms Valve Flow High LimitRead
Alarms Valve Flow Low LimitRead
Alarms EC1 EC2 DeviationRead
Alarms pH1 pH2 DeviationRead
Alarms EC1 ErrorRead
Alarms pH1 ErrorRead
Alarms WT Failure BitmaskRead
Alarms Bio Flow ActiveRead
Decoder AlarmRead
Input Extern Stand ByRead
Input Tank Level Switch BottomRead
Input Basin 0 Level 1Read
Input Pressure SwitchRead
Input Boom StopRead
Output Basin Pump 0Read
Output Basin Pump 1Read
Output Basin Pump 2Read
Output Basin Pump 3Read
Output Basin Pump 4Read
Output Basin Pump 5Read
Output Basin Pump 6Read
Output Basin Pump 7Read
Output Water Supply ValveRead
IO Tank Level Switch TopRead
Output UV LightRead
Output Mixing Valve CloseRead
Output Mixing Valve OpenRead
Output Alarm 0Read
Output Alarm 1Read
Input External AlarmRead
Input Pump AlarmRead
Output Dosing Valve 0Read
Output Dosing Valve 1Read
Output Dosing Valve 2Read
Output Dosing Valve 3Read
Output Dosing Valve 4Read
Output Dosing Valve 5Read
Output Dosing Valve 6Read
Output Dosing Valve 7Read
Output Main Pump 0Read
Output Dosing AcidRead
Output Dosing AlkalineRead
Output Dosing Pump 0Read
Output Dosing Pump 1Read
Output Dosing Pump 2Read
Output Dosing Pump 3Read
Output Dosing Pump 4Read
Output Dosing Pump 5Read
Output Dosing Pump 6Read
Output Dosing Pump 7Read
Output Filter Clean 0Read
Output Filter Clean 1Read
Output Filter Clean 2Read
Output Main Pump 1Read
Input Basin 1 Level 1Read
Input Basin 2 Level 1Read
Input Basin 3 Level 1Read
Input Basin 4 Level 1Read
Input Basin 5 Level 1Read
Input Basin 6 Level 1Read
Input Basin 7 Level 1Read
Input Basin 0 Level 2Read
Input Basin 1 Level 2Read
Input Basin 2 Level 2Read
Input Basin 3 Level 2Read
Input Basin 4 Level 2Read
Input Basin 5 Level 2Read
Input Basin 6 Level 2Read
Input Basin 7 Level 2Read
Input Basin 0 Level 3Read
Input Basin 1 Level 3Read
Input Basin 2 Level 3Read
Input Basin 3 Level 3Read
Input Basin 4 Level 3Read
Input Basin 5 Level 3Read
Input Basin 6 Level 3Read
Input Basin 7 Level 3Read
Output Supply PumpRead
Input Flow Sensor 0Read
Input Flow Sensor 1Read
Output Return Valve Basin OpenRead
Output Return Valve Basin CloseRead
Output Return Valve Fresh Water OpenRead
Output Return Valve Fresh Water CloseRead
Input Tank Level Switch TopRead
Input Bio Fert A Flow SensorRead
Input Bio Fert B Flow SensorRead
Input Bio Fert C Flow SensorRead
Input Bio Fert D Flow SensorRead
Input Bio Fert E Flow SensorRead
Input Bio Fert F Flow SensorRead
Input Bio Fert G Flow SensorRead
Input Bio Fert H Flow SensorRead
Output Bio Fert A ValveRead
Output Bio Fert B ValveRead
Output Bio Fert C ValveRead
Output Bio Fert D ValveRead
Output Bio Fert E ValveRead
Output Bio Fert F ValveRead
Output Bio Fert G ValveRead
Output Bio Fert H ValveRead
Output Basin RV Open 0Read
Output Basin RV Open 1Read
Output Basin RV Open 2Read
Output Basin RV Open 3Read
Output Basin RV Open 4Read
Output Basin RV Open 5Read
Output Basin RV Open 6Read
Output Basin RV Open 7Read
Output Basin RV Close 0Read
Output Basin RV Close 1Read
Output Basin RV Close 2Read
Output Basin RV Close 3Read
Output Basin RV Close 4Read
Output Basin RV Close 5Read
Output Basin RV Close 6Read
Output Basin RV Close 7Read
Output Basin RV OpenRead
Analog Output Dosing Valve 0Read
Analog Output Dosing Valve 1Read
Analog Output Dosing Valve 2Read
Analog Output Dosing Valve 3Read
Analog Output Dosing Valve 4Read
Analog Output Dosing Valve 5Read
Analog Output Dosing Valve 6Read
Analog Output Dosing Valve 7Read
Analog Output Dosing Valve Voltage 0VRead
Analog Output Dosing Valve Voltage 1VRead
Analog Output Dosing Valve Voltage 2VRead
Analog Output Dosing Valve Voltage 3VRead
Analog Output Dosing Valve Voltage 4VRead
Analog Output Dosing Valve Voltage 5VRead
Analog Output Dosing Valve Voltage 6VRead
Analog Output Dosing Valve Voltage 7VRead
Analog Output Dosing Common ValveRead
Analog Output Dosing Common Valve VoltageVRead
Decoder IORead
Control Manual StandbyRead and write
Control Common StandbyRead and write
Control Use Hose IrrigationRead and write
Control Operation ModeRead and write
Control Cancel Current IrrigationRead and write
Control Cancel AllRead and write
Control Stop MixerRead and write
Control Manual Valve StartRead and write
Control Reset Irrigation CyclesRead and write
Control Reset Water VolumeRead and write
Control Reset Remaining Irrigation CyclesRead and write
Sensor 7 GainRead and write
Sensor 7 OffsetRead and write
EC1 Avg TimesRead and write
EC1 GainRead and write
EC1 OffsetRead and write
EC2 Avg TimesRead and write
EC2 GainRead and write
EC2 OffsetRead and write
pH1 Avg TimesRead and write
pH1 GainRead and write
pH1 OffsetRead and write
pH2 Avg TimesRead and write
pH2 GainRead and write
pH2 OffsetRead and write
Flow 1K FactorRead and write
Flow 1 InstalledRead and write
Flow Sensor 2 TypeRead and write
Flow 2K FactorRead and write
Flow 3K FactorRead and write
Hose Irrigation TimesRead and write
Time Averaging For Sun MeasuresRead and write
Geo Time LatitudeRead and write
Geo Time LongitudeRead and write
Geo Time Summer TimeRead and write
Geo Time GMTRead and write
Recipe For Hose IrrigationRead and write
Misc Filter Clean PermissionRead and write
Basin No For Hose IrrigationRead and write
Water Supply Fresh Water Dose AllowedRead and write
Water Supply Period Time Fresh Water DosingsRead and write
Water Supply P Factor Fresh Water DosingRead and write
Delay For Start Pump 2sRead and write
Pumps Pressure Control ActiveRead and write
Supply Pump Stop DelaysRead and write
Valve Start DelaysRead and write
Water Supply ModeRead and write
Water Supply Sensor For Fresh Water DosingRead and write
Water Supply Mixing Valve Idle PositionRead and write
Number Of PumpsRead and write
UV EnabledRead and write
UV Pre Start TimesRead and write
UV Stop DelaysRead and write
Mixer Flow HysteresisRead and write
Mixer Manual Valve ModeRead and write
Filter Clean IntervalsRead and write
Basin Pressure Pump SelectorRead and write
Filter Clean Active SettingRead and write
Filter Clean Filter Rinse TimesRead and write
Filter Clean Manual Clean Valve 1Read and write
Filter Clean Wait Until FinishedRead and write
Filter Clean Pause Between FilterssRead and write
Filter Clean Manual Clean Valve 2Read and write
Filter Clean Manual Clean Valve 3Read and write
No Filter CleanRead and write
No Filter Clean 1Read and write
No Filter Clean 3Read and write
Mixer EC I FactorRead and write
Mixer EC D FactorRead and write
Mixer EC pH Controller Minimum Step Length ECRead and write
Mixer Dosage Interval EC msRead and write
Mixer EC pH Controller Max Duty Cycle ECRead and write
Mixer EC pH Controller Min Duty Cycle ECRead and write
Mixer P Factor Fresh Water pHRead and write
Mixer P Factor Basin Water pHRead and write
Mixer pH I FactorRead and write
Mixer pH Dosage IntervalRead and write
Mixer EC Diff Time ConstantsRead and write
Mixer pH Diff Time ConstantsRead and write
Mixer EC Error Gain PositiveRead and write
Mixer EC P FactorRead and write
Mixer Service FlowRead and write
Mixer Service Fresh Water EC SimulRead and write
Mixer Concentration Stock Sol CommonRead and write
Mixer Service Pump CapacityRead and write
Mixer Concentration Stock Sol ARead and write
Mixer Pump Capacity Stock Sol ARead and write
Mixer Dosing Factorratio 1Read and write
Mixer Fresh Water pHRead and write
Mixer Basin Water pHRead and write
Ramp Of Increase pHRead and write
Ramp Of Decrease pHRead and write
Mixer Dosing Valve Adjust ARead and write
Mixer Dosing Valve Adjust BRead and write
Mixer Dosing Valve Adjust CRead and write
Mixer Dosing Valve Adjust DRead and write
Mixer Dosing Valve Adjust ERead and write
Mixer Dosing Valve Adjust FRead and write
Mixer Dosing Valve Adjust GRead and write
Mixer Dosing Valve Adjust HRead and write
Mixer Dosing Pump Stop DelaysRead and write
Pump 2 AllowedRead and write
Pump 2 Start HysteresisRead and write
Hose Irrigation Hose Irr Pressure DemRead and write
Pumps ItimesRead and write
Pumps PfactorRead and write
Pump 2 Min SpeedRead and write
Pump 1 Min SpeedRead and write
Pump 1 Speed For Start Pump 2Read and write
Mixer Acid Alkaline Switch DelaysRead and write
Mixer Acid Alkaline Switch HystRead and write
Mixer Service Ml Pr Litre For 1EC 0Read and write
Mixer Service Ml Pr Litre For 1EC 1Read and write
Mixer Service Ml Pr Litre For 1EC 2Read and write
Mixer Service Ml Pr Litre For 1EC 3Read and write
Mixer Service Ml Pr Litre For 1EC 4Read and write
Mixer Service Ml Pr Litre For 1EC 5Read and write
Mixer Service Ml Pr Litre For 1EC 6Read and write
Mixer Service Ml Pr Litre For 1EC 7Read and write
Mixer Rhythm Box Start DelayRead and write
EC1 Voltage Error ARead and write
EC1 Voltage Error BRead and write
EC2 Voltage Error ARead and write
EC2 Voltage Error BRead and write
pH1 Voltage Error ARead and write
pH1 Voltage Error BRead and write
pH2 Voltage Error ARead and write
pH2 Voltage Error BRead and write
EC1 Short Avg TimesRead and write
EC2 Short Avg TimesRead and write
pH1 Short Avg TimesRead and write
pH2 Short Avg TimesRead and write
EC2 InstalledRead and write
pH2 InstalledRead and write
Mixer Return Compensation pH ActiveRead and write
Mixer pH D FactorRead and write
Mixer Acid Fert Tank NumberRead and write
Mixer Alkaline Fert Tank NumberRead and write
Mixer Start Up PID Suppression TimesRead and write
Flow 2 InstalledRead and write
Flow 1 PositionRead and write
Water Supply Mixing Valve InstalledRead and write
Hose Irrigation Dist Start Fresh Water DosingRead and write
Hose Irrigation Mix Fresh And Return WaterRead and write
Hose Irrigation Basin Control EnabledRead and write
Hose Irrigation EC Dist For Start Incr FreshwaterRead and write
Hose Irrigation pH Dist For Start Incr FreshwaterRead and write
Hose Irrigation Fresh Water Pct Level 1 2%Read and write
Hose Irrigation Fresh Water Pct Level 2 3%Read and write
Hose Irrigation Fresh Water Pct Level 3 Plus%Read and write
Hose Irrigation Incr Fresh Water High ECRead and write
Hose Irrigation Incr Fresh Water By Low pHRead and write
pH1 InstalledRead and write
Mixer Use Return ValvesRead and write
Mixer VLT Pump 1Read and write
Mixer Pre Start DelaysRead and write
Basins 0 Level 1 HeightRead and write
Basins 0 Level 2 HeightRead and write
Basins 0 Level 3 HeightRead and write
Basins 1 Level 1 HeightRead and write
Basins 1 Level 2 HeightRead and write
Basins 1 Level 3 HeightRead and write
Basins 2 Level 1 HeightRead and write
Basins 2 Level 2 HeightRead and write
Basins 2 Level 3 HeightRead and write
Basins 3 Level 1 HeightRead and write
Basins 3 Level 2 HeightRead and write
Basins 3 Level 3 HeightRead and write
Basins 4 Level 1 HeightRead and write
Basins 4 Level 2 HeightRead and write
Basins 4 Level 3 HeightRead and write
Basins 5 Level 1 HeightRead and write
Basins 5 Level 2 HeightRead and write
Basins 5 Level 3 HeightRead and write
Basins 6 Level 1 HeightRead and write
Basins 6 Level 2 HeightRead and write
Basins 6 Level 3 HeightRead and write
Basins 7 Level 1 HeightRead and write
Basins 7 Level 2 HeightRead and write
Basins 7 Level 3 HeightRead and write
Basin Use Linear SensorsRead and write
Water Supply 2 Low Level Pump TimesRead and write
Water Supply 2 Low Level Pump SpeedRead and write
Basin HysteresisRead and write
Mixer Service Tank Empty TypeRead and write
Use SuperlinkRead and write
Use Initiator EnabledRead and write
Solar Cell ChoiceRead and write
Analog 0 MinRead and write
Analog 1 MinRead and write
Analog 2 MinRead and write
Analog 3 MinRead and write
Analog 4 MinRead and write
Analog 5 MinRead and write
Analog 6 MinRead and write
Analog 7 MinRead and write
Analog 0 MaxRead and write
Analog 1 MaxRead and write
Analog 2 MaxRead and write
Analog 3 MaxRead and write
Analog 4 MaxRead and write
Analog 5 MaxRead and write
Analog 6 MaxRead and write
Analog 7 MaxRead and write
Hose Irrigation Auto StartRead and write
Hose Irrigation Manual StartRead and write
Hose Irrigation Disabled Out APRead and write
Hose Irrigation Start TimesRead and write
Hose Irrigation End TimesRead and write
Water Supply Tank Top Level InstalledRead and write
Pump 1 Fault ResetRead and write
Pump 2 Fault ResetRead and write
Mixer Min Duty Cycle pHRead and write
Mixer Max Duty Cycle pHRead and write
Local WT Bar Pressure Av TimesRead and write
Local WT Bar Pressure GainRead and write
Local WT Bar Pressure OffsetRead and write
Local WT Light Intensity Av TimesRead and write
Local WT Light Intensity GainRead and write
Local WT Light Intensity OffsetRead and write
Local WT Light Intensity Sensor TypeRead and write
Local WT Outdoor Humidity Av TimesRead and write
Local WT Outdoor Humidity GainRead and write
Local WT Outdoor Humidity OffsetRead and write
Local WT Sun Radiation Av TimesRead and write
Local WT Sun Radiation GainRead and write
Local WT Sun Radiation OffsetRead and write
Local WT Temperature GainRead and write
Local WT Temperature Av TimesRead and write
Local WT Temperature OffsetRead and write
Local WT Wind Direction Av TimesRead and write
Local WT Wind Direction GainRead and write
Local WT Wind Direction OffsetRead and write
Local WT Wind Speed Av TimesRead and write
Local WT Wind Speed Decrease TimesRead and write
Local WT Wind Speed Increase TimesRead and write
Local WT Wind Speed PeakRead and write
Local WT Wind Speed Gain AnalogRead and write
Local WT Wind Speed Gain DigitalRead and write
Local WT Wind Speed OffsetRead and write
Solar WT ChoiceRead and write
Rain Gauge Rain ResolutionRead and write
Solar Is Sun V2Read and write
Pumps Filter Clean Active SelectorRead and write
Mixer Bio PfactorRead and write
Mixer Bio IfactorRead and write
Mixer Bio DfactorRead and write
Mixer Bio Diff Time ConstantsRead and write
Mixer Bio DogtailRead and write
Mixer Bio Fertilizer 0 GainRead and write
Mixer Bio Average TimesRead and write
Mixer Bio Integral FreezeRead and write
Mixer Bio Fertilizer 1 GainRead and write
Mixer Bio Fertilizer 2 GainRead and write
Mixer Bio Fertilizer 3 GainRead and write
Mixer Bio Fertilizer 4 GainRead and write
Mixer Bio Fertilizer 5 GainRead and write
Mixer Bio Fertilizer 6 GainRead and write
Mixer Bio Fertilizer 7 GainRead and write
Mixer Bio Fertilizer 0 OffsetRead and write
Mixer Bio Fertilizer 1 OffsetRead and write
Mixer Bio Fertilizer 2 OffsetRead and write
Mixer Bio Fertilizer 3 OffsetRead and write
Mixer Bio Fertilizer 4 OffsetRead and write
Mixer Bio Fertilizer 5 OffsetRead and write
Mixer Bio Fertilizer 6 OffsetRead and write
Mixer Bio Fertilizer 7 OffsetRead and write
Pumps Control ModeRead and write
Pumps Min PressureRead and write
Pumps Max PressureRead and write
Pumps Manual ModeRead and write
Pump 1 Manual Speed DemRead and write
Pump 2 Manual Speed DemRead and write
Tank Alarm Delay Low LevelsRead and write
Alarms Tank Start Delay After Low LevelsRead and write
Common Alarm Active Bit MaskRead and write
Alarms Tank Use Latched Low Level StopRead and write
Alarm Relay DelaysRead and write
Alarm Delay ECsRead and write
Alarm Delay pHsRead and write
EC Alarm Always ActiveRead and write
pH Alarm Always ActiveRead and write
Alarm Delay Mixer FlowsRead and write
EC1 Alarm EnabledRead and write
pH1 Alarm EnabledRead and write
EC2 Alarm EnabledRead and write
pH2 Alarm EnabledRead and write
EC2 Absolute Low Alarm SettingRead and write
EC2 Absolute High Alarm SettingRead and write
EC2 Relative EC1 AlarmRead and write
pH2 Absolute Low Alarm SettingRead and write
pH2 Absolute High Alarm SettingRead and write
pH2 Relative pH1 AlarmRead and write
Alarm 01 Start TimesRead and write
Alarm 01 Stop TimesRead and write
Alarm 02 Start TimesRead and write
Alarm 02 Stop TimesRead and write
Mixer Flow Maximum Flow For Alarm When ActiveRead and write
Mixer Flow Maximum Flow For Alarm When Not ActiveRead and write
Mixer Flow Dev On Valves For AlarmRead and write
Alarm Selection Group Flow Alarm EnabledRead and write
Mixer Flow Alarm EnabledRead and write
Alarm Selection External Alarm EnabledRead and write
Alarm Selection Fertilizer Dosing Alarm EnabledRead and write
Alarm Selection Valve Alarms EnabledRead and write
Alarm Selection Irrigation Boom Alarm EnabledRead and write
Alarm Selection Sensor Failure Alarm EnabledRead and write
Alarms Sensor Fail EC Sensor 1 EnabledRead and write
Alarms Sensor Fail EC Sensor 2 EnabledRead and write
Alarms Sensor Fail pH Sensor 1 EnabledRead and write
Alarms Sensor Fail pH Sensor 2 EnabledRead and write
Alarms Sensor Fail Flow Sensor 1 EnabledRead and write
Alarms Sensor Fail Flow Sensor 2 EnabledRead and write
Alarms Sensor Fail Flow Sensor 3 EnabledRead and write
Alarms Sensor Fail Temperature Sensor EnabledRead and write
Alarms Sensor Fail Humidity Sensor EnabledRead and write
Alarms Sensor Fail Solar Cell 1 EnabledRead and write
Alarms Sensor Fail Solar Cell 2 EnabledRead and write
Alarms Sensor Fail Solar Cell 3 EnabledRead and write
Alarms Sensor Fail Solar Cell 4 EnabledRead and write
EC1 Absolute Low Alarm EnableRead and write
EC1 Absolute High Alarm EnableRead and write
EC1 Relative Low Alarm EnableRead and write
EC1 Relative High Alarm EnableRead and write
pH1 Absolute Low Alarm EnableRead and write
pH1 Absolute High Alarm EnableRead and write
pH1 Relative Low Alarm EnableRead and write
pH1 Relative High Alarm EnableRead and write
EC2 Absolute Low Alarm EnableRead and write
EC2 Absolute High Alarm EnableRead and write
pH2 Absolute Low Alarm EnableRead and write
pH2 Absolute High Alarm EnableRead and write
EC1 EC2 Deviation Alarm EnableRead and write
pH1 pH2 Deviation Alarm EnableRead and write
Valve Flow Alarm EnableRead and write
Group Flow Alarm EnableRead and write
Mixer Flow Alarm EnableRead and write
External Alarm EnableRead and write
Fertilizer Level Alarms EnableRead and write
Fertilizer Dosing Alarm EnableRead and write
Valve Alarms EnableRead and write
Irrigation Boom Alarm EnableRead and write
ARCnet Alarm EnableRead and write
Distributed IO Alarm EnableRead and write
Alarms Sensor Failure EnableRead and write
Tank Low Level AlarmRead and write
Reaction EC1 Absolute Low Alarm SelectorRead and write
Reaction EC1 Absolute High Alarm SelectorRead and write
Reaction EC1 Relative Low Alarm SelectorRead and write
Reaction EC1 Relative High Alarm SelectorRead and write
Reaction pH1 Absolute Low Alarm SelectorRead and write
Reaction pH1 Absolute High Alarm SelectorRead and write
Reaction pH1 Relative Low Alarm SelectorRead and write
Reaction pH1 Relative High Alarm SelectorRead and write
Reaction EC2 Absolute Low Alarm SelectorRead and write
Reaction EC2 Absolute High Alarm SelectorRead and write
Reaction pH2 Absolute Low Alarm SelectorRead and write
Reaction pH2 Absolute High Alarm SelectorRead and write
Reaction EC1 EC2 Deviation Alarm SelectorRead and write
Reaction pH1 pH2 Deviation Alarm SelectorRead and write
Reaction Valve Flow Alarm SelectorRead and write
Reaction Group Flow Alarm SelectorRead and write
Reaction Mixer Flow Alarm SelectorRead and write
Reaction External Alarm SelectorRead and write
Reaction Fertilizer Level Alarms SelectorRead and write
Reaction Fertilizer Dosing Alarm SelectorRead and write
Reaction Valve Alarms SelectorRead and write
Reaction Irrigation Boom Alarm SelectorRead and write
Reaction ARCnet Alarm SelectorRead and write
Reaction Distributed IO Alarm SelectorRead and write
Reaction Sensor Failure SelectorRead and write
Reaction Pump Alarm SelectorRead and write
Common Reset Alarm DelayRead and write
Pump Alarm EnableRead and write
Alarms Tank Start Delay After Top LevelsRead and write
VLT1 Pump Alarm EnableRead and write
VLT2 Pump Alarm EnableRead and write
Reaction VLT1 Pump Alarm SelectorRead and write
Reaction VLT2 Pump Alarm SelectorRead and write
Alarms VLT1 Idle DelaysRead and write
Alarms VLT2 Idle DelaysRead and write
Pump 1 Idle Alarm EnableRead and write
Pump 2 Idle Alarm EnableRead and write
Reaction Pump 1 Idle Alarm SelectorRead and write
Reaction Pump 2 Idle Alarm SelectorRead and write
VLT1 Alarm DelaysRead and write
VLT2 Alarm DelaysRead and write
Alarms WT Failure EnableRead and write
Reaction WT Failure SelectorRead and write
Enable WT AlarmRead and write
Alarms Sensor Fail Local WT Pressure EnabledRead and write
Alarms Sensor Fail Local WT Out Light EnabledRead and write
Alarms Sensor Fail Local WT Humidity EnabledRead and write
Alarms Sensor Fail Local WT Sun Rad EnabledRead and write
Alarms Sensor Fail Local WT Temperature EnabledRead and write
Alarms Sensor Fail Local WT Wind Dir EnabledRead and write
Alarms Sensor Fail Local WT Wind Speed EnabledRead and write
Enable By HoseRead and write
Alarms Bio Flow DelaysRead and write
Alarms Bio Flow EnableRead and write
Alarms Bio Flow Relative LowRead and write
Reaction Bio Flow Alarm SelectorRead and write
Bio Flow Alarm EnableRead and write
Reaction Decoder Alarm SelectorRead and write
Decoder Alarm EnableRead and write
Decoder Alarm DelaysRead and write
Group Valve PauseRead
Mixer Alarm Disable At StartsRead and write
Mixer Reset By AlarmRead and write
Mixer pH Control ModeRead and write
Groups Drainage IndexRead
Old IO Digital In 10Read and write
Old IO Digital In 11Read and write
Old IO Digital In 12Read and write
Old IO Digital In 13Read and write
Old IO Digital In 14Read and write
Old IO Digital In 15Read and write
Active Recipe 1 Time Period For Sun MeasuresRead and write
Active Recipe 2 Time Period For Sun MeasuresRead and write
Active Recipe 3 Time Period For Sun MeasuresRead and write
Active Recipe 4 Time Period For Sun MeasuresRead and write
Active Recipe 5 Time Period For Sun MeasuresRead and write
Active Recipe 6 Time Period For Sun MeasuresRead and write
Active Recipe 7 Time Period For Sun MeasuresRead and write
Control Boot FlagRead and write
Unknown IG00004Read
Service Dawn Dusk DelaysRead and write
Misc Valve Pause ActiveRead and write
Misc Filter Clean In Valve PauseRead and write
Extern Standby SelectRead and write
pH Acid Alarm BitmaskRead and write
pH Alkaline Alarm BitmaskRead and write
Mixer Unknown Group Valve PauseRead
Internal Water Request BM0001Read
Mixer Unknown Pump RequestRead
Mixer Unknown BM0010sRead
Internal NOT EC Dos AlarmRead
Internal NOT pH Dos AlarmRead
Internal NOT Other AlarmRead
Mixer Unknown Alarm OKRead
Mixer Unknown Recipe RequestRead
Internal Water RequestRead
Unknown BP0008Read
Unknown Post RinseRead
Mixer Manual Pump 1Read and write
Mixer Pressure Pump ModeRead and write
Mixer Pressure Pump Start DelaysRead and write
Mixer Pressure Pump Stop DelaysRead and write
Mixer Pump 2 Start Condition ModeRead and write
Mixer Supply Pump Pre Start DelaysRead and write
Mixer Maximum Time For Start ValvessRead and write
Mixer Pump Dosing Stop DelaysRead and write
Mixer pH Acid Dosing EnabledRead and write
Mixer pH Alkaline Dosing EnabledRead and write
Mixer Pump 2 Depending On Pressure FlowRead and write
Mixer Start Pump 2 By Low PressureRead and write
Mixer Number Of Stock SolutionsRead and write
Mixer Capacity Pump ARead and write
Mixer Capacity Pump BRead and write
Mixer Tank VolumeRead and write
Mixer Fresh Water CapacityRead and write
Mixer Filter Cleaning ModeRead and write
Mixer Number Of ValvesRead and write
Mixer Pump Service IntervalRead and write
Mixer Sensor Calibration IntervalRead and write
Mixer pH Sensor Exchange IntervalRead and write
Mixer Active Start ConditionRead
Mixer Override FertilizerRead
Mixer Switch Time Fert PumpsRead
Mixer Switch Time Start ValuessRead
Mixer Pump 1 Switch TimesRead
Mixer Pump 2 Switch TimesRead
Unknown Pressure Pump 1 Final ActiveRead
Unknown Pressure Pump 2 Final ActiveRead
Internal Valve ActiveRead
Unknown Supply Pump SwitchtimesRead
Water Supply Pause FactorRead and write
Water Supply Step FactorRead and write
Water Supply Pulse Pause GainRead and write
Water Supply Clock Last ActivitysRead
Water Supply Clock Last Off StatesRead
Water Supply Clock Last On StatesRead
Water Supply Last Active DirectionRead
Water Supply Last Requested StateRead
Water Supply P Factor Incr Fresh Water By ECRead and write
Water Supply P Factor Incr Fresh Water By pHRead and write
Mixer Unknown Mixing Valve StateRead
Mixer Acid TypeRead and write
Filter Clean Valve 1Read and write
Unknown BF0002 Filter Clean PendingRead
Filter Clean Active StatusRead
Filter Clean Valve 2Read and write
Filter Clean Valve 3Read and write
Mixer Return Comp P Factor pHRead and write
Mixer Return Comp ItimesRead and write
Mixer Return Comp Ramp IncrRead and write
Mixer Return Comp Ramp DecrRead and write
Mixer EC pH Controller Period For Water DosingsRead and write
Mixer EC pH Controller Pfactor For Water DosingRead and write
Mixer EC pH Controller P Factor Flow DependencyRead and write
Mixer EC pH Controller P Factor Fresh Water Prm SRead and write
Mixer EC pH Controller P Factor Basin Water Prm SRead and write
Mixer EC pH Controller pH D TimesRead and write
Mixer EC pH Controller Min Step Length pHRead and write
Mixer EC pH Controller Max Duty Cycle pHRead and write
Mixer EC pH Controller Min Duty Cycle pHRead and write
Mixer EC pH Controller EC Exp Error FactorRead and write
Mixer EC pH Controller EC Error Gain Below ZeroRead and write
Mixer EC pH Controller EC Error Gain Above ZeroRead and write
EC pH Controller EC Error Gain NegativeRead and write
EC pH Controller EC Error AvgRead
EC pH Controller EC pH Factor Pre Flow CorrRead
EC pH Controller PID Duty Cycle ContribRead
EC pH Controller PID Contrib Duty Cycle pHRead
Unknown BEC012Read
Unknown BEC013 Cycle CountRead
Unknown BEC014 Cycle CompletedRead
Unknown IEC011Read
EC pH Controller Avg Time ECsRead and write
EC pH Controller P Factor Return CompRead and write
EC pH Controller Itime Return CompsRead and write
EC pH Controller Ramp Incr Sun CompRead and write
EC pH Controller Ramp Desc Sun CompRead and write
EC pH Controller Ramp Incr Return CompRead and write
EC pH Controller Ramp Desc Return CompRead and write
Mixer EC pH Controller EC Duty Cycle Init Dosing Factor EC1Read and write
Mixer EC pH Controller EC Duty Cycle Init Basin Water EC SimulRead and write
Mixer EC pH Controller EC Duty Cycle Init Ramp Of Increase MinRead and write
Mixer EC pH Controller EC Duty Cycle Init Ramp Of Decrease MinRead and write
EC pH Controller Fresh Water Duty CycleRead
EC pH Controller Fixed Ratio Fertilizer A Duty CycleRead
EC pH Controller EC Contr Gain FeedbackRead
EC pH Controller Basin UsedRead
EC pH Controller Direct Reading EC1Read
EC pH Controller Direct Reading EC2Read
EC pH Controller Direct Reading pH2Read
EC pH Controller Direct Read FlowRead
EC pH Controller Flow 1 Sensor FailureRead
EC pH Controller Flow 2 Sensor FailureRead
EC pH Controller Flow 3 Sensor FailureRead
EC pH Controller Solar Cell 1 Sensor FailureRead
EC pH Controller Solar Cell 2 Sensor FailureRead
EC pH Controller Solar Cell 3 Sensor FailureRead
EC pH Controller Solar Cell 4 Sensor FailureRead
Alarm Delay Valve FlowsRead and write
Alarm Delay Group FlowsRead and write
Fertilizer Alarm Delay Dosing FailuresRead and write
Alarms Internal Abs High EC ActiveRead
Alarms Internal Abs Low EC ActiveRead
Alarms Internal Rel High EC ActiveRead
Alarms Internal Rel Low EC ActiveRead
Mixer Flow Dev On Valves For Alarm SkipRead and write
Alarms Internal Abs High pH ActiveRead
Alarms Internal Abs Low pH ActiveRead
Alarms Internal Rel High pH ActiveRead
Alarms Internal Rel Low pH ActiveRead
Alarms Internal EC2 Abs High ActiveRead
Alarms Internal EC2 Abs High LevelRead
Alarms Internal EC2 Abs Low ActiveRead
Internal EC2 Rel EC1 Alarm ActiveRead
Alarms Internal pH2 Abs High ActiveRead
Alarms Internal pH2 Abs ActiveRead
Alarms Internal pH2 Rel pH1 ActiveRead
Alarm Selection Valve Flow Alarm EnabledRead and write
Alarm Selection Fertilizer Level Alarm EnabledRead and write
Alarm Selection Distributed IO Alarm EnabledRead and write
Valve Flow External AlarmRead
Valve Flow ARCnet AlarmRead
Valve Flow Distributed IO AlarmRead
Alarms Sensor Fail Solar Cell 5 EnabledRead and write
Alarms Sensor Fail Solar Cell 6 EnabledRead and write
Alarms Sensor Fail Solar Cell 7 EnabledRead and write
Alarms Sensor Fail Solar Cell 8 EnabledRead and write
Unknown Manual Reconfig Exp 1Read
Unknown Last Alarm Bit PatternRead
Alarm Relay EnableRead and write
Unknown Alarm BellRead
Unknown Alarm Bell Switch TimesRead
Alarm CauseRead
Previous Alarm StatusRead
Previous Alarm Status 2Read
Unknown Allowed Alarms Bit MaskRead
Unknown S10301Read
Unknown UAL113Read
Dose Pump EndRead
Mixer Active Return Valve NoRead
Mixer Local Solar Cell 2 ReadingRead
Mixer Local Solar Cell 3 ReadingRead
Mixer Local Solar Cell 4 ReadingRead
Mixer Local Solar Cell 5 ReadingRead
Unknown S141005Read
Unknown Valve 000Read
Unknown S31000sRead
Mixer Active Valve Number In Pos 1Read
Mixer Active Valve Number In Pos 2Read
Mixer Active Valve Number In Pos 3Read
Mixer Active Valve Number In Pos 4Read
Internal Valve Active Or Tank EmptyingRead
Unknown S31400 0Read
Mixer Unknown Flow Dev HysteresisRead
Flow Alarm ActiveRead
Internal Valve Flow Alarm EventRead
Unknown Valve Flow Switch TimeRead
Actual Ami Group EC IntegralRead
Unknown IPH016 LevelRead
Unknown IPH015 Time For SwitchsRead
Unknown IPH011Read
Unknown IPH041Read
Unknown Sxx 899Read
Unknown BR036 Acid Dosing DCRead
Unknown BR037 Alkaline Dosing DCRead
Unknown BR033 Dose IntervalmsmsRead
Mixer Active Ratio On Stock Solution ARead and write
Mixer Active Ratio On Stock Solution BRead and write
Mixer Active Ratio On Stock Solution CRead and write
Mixer Active Ratio On Stock Solution DRead and write
Mixer Active Ratio On Stock Solution ERead and write
Mixer Active Ratio On Stock Solution FRead and write
Mixer Active Ratio On Stock Solution GRead and write
Mixer Active Ratio On Stock Solution HRead and write
Unknown IEC061Read
Unknown BR023Read
Internal Old System StateRead
Internal Last Standby ResetRead
Group Executer Recipe No RequestRead
Group Executer Skip Value By Irr BoomRead
Internal Stop SignalRead
Group Executer System StateRead
Active Recipe IndexRead
Sun RadRead
Unknown Volume InRead
Pumps Avg TimesRead and write
Pump GainRead and write
Pump OffsetRead and write
Pump Pressure VoltVRead
Unknown S31400 1Read
Unknown S31400 2Read
Unknown S31400 3Read
Mixer Return Compensation EC ActiveRead and write
Water Supply Fresh Water Clock Last ActivitysRead
Water Supply Fresh Water Clock Last Off StatesRead
Water Supply Fresh Water Clock Last On StatesRead
Water Supply Basin Clock Last ActivitysRead
Water Supply Basin Clock Last Off StatesRead
Water Supply Basin Clock Last On StatesRead
Water Supply Fresh Water Last Active DirectionRead
Water Supply Basin Last Active DirectionRead
Water Supply Fresh Water Last Requested StateRead
Water Supply Basin Last Requested StateRead
Version V0R11Read
Analog 0 NameRead and write
Analog 1 NameRead and write
Analog 2 NameRead and write
Analog 3 NameRead and write
Analog 4 NameRead and write
Analog 5 NameRead and write
Analog 6 NameRead and write
Analog 7 NameRead and write
Mixer Active Recipe NameRead
Mixer Active Group NameRead
Mixer Activity Total Valve TimeRead

Loading registers…

The ModbusCloud Gateway, front at an angle, with the RS485 terminal and the antenna connectors

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Use cases

  • Show EC1, EC2, pH1 and pH2 of the irrigation water next to the EC and pH demand on one dashboard.
  • Get an email when the stop alarm or the alarm relay of the mixer becomes active.
  • Keep a year of flow, volume and pressure history to compare water use per season.
  • Alert on an EC or pH sensor failure so a probe is cleaned or replaced before the next irrigation.
  • Put the mixer in standby or change an alarm limit from the portal without driving to the greenhouse.

Installation

  1. Connect the ModbusCloud Gateway to the Ethernet network of the AMI Penta. Senmatic recommends a separate network for its controllers.

  2. Look up the IP address of the AMI Penta under Unit setup, IP address. It is in the 10.4.1.xxx range with subnet 255.255.255.0.

  3. In ModbusCloud, add a Modbus device with Modbus TCP, that IP address, port 502 and unit ID 0, and import this template.

  4. Check that EC1, pH1 and the system state come in and match the display of the AMI Penta.

  5. For weather data and irrigation groups, add a Modbus device per unit ID with the matching Senmatic AMI Penta template.

Things to watch for

Which unit ID belongs to which data of the AMI Penta?

Unit ID 0 holds the system data, the valve table and the list of hand-started valves, each in its own template. Unit ID 200 holds the weather data. Every irrigation group answers on its own unit ID together with the recipe of the same number: group 1 and recipe 1 on unit ID 1, group 2 and recipe 2 on unit ID 2.

The Gateway gets no answer from the AMI Penta. What should I check?

Check that the Gateway reaches the IP address set under Unit setup on the AMI Penta, usually 10.4.1.xxx with subnet 255.255.255.0, and that the Modbus device uses port 502 and unit ID 0. Senmatic recommends a separate Ethernet network for its controllers, so connect the Gateway to that network.

In which units are the values and times shown?

EC, pH, flow, volume and pressure come as plain numbers in the units the AMI Penta uses itself, so compare one value with the display of the controller. Durations and times of day are shown in seconds: a start time of 06:00 reads 21600 s. Yes or no values read 1 or 0.

Can I change settings of the AMI Penta from ModbusCloud?

Yes, standby, cancel and reset commands, sensor calibration and the controller, pump and alarm settings are writable. Writing is off per gateway until you request it in the portal. A wrong value changes how the AMI Penta irrigates and doses, so read the current value first and change one setting at a time.

Want to see how it works?

Electrician working in an open distribution board