TROX X-CUBE
Central air handling unit with integrated controller for ventilation, heat recovery, heating and cooling.
The TROX X-CUBE is a central air handling unit with its own controller that ventilates, recovers heat, heats, cools and controls humidity in offices, schools and other non-residential buildings. This Modbus TCP template reads air temperatures, humidity, pressures, airflow, air quality and all fault states, and lets you set the operating mode, standby and fan and temperature setpoints from ModbusCloud.
- Protocol
- Modbus TCP
- Connection
- Ethernet, Modbus TCP
- Registers
- 183, read and write
- Brand
- TROX
- Key readings
- Supply air temperature · Extract air temperature · Relative humidity · Airflow · Duct pressure · CO2 concentration · Filter differential pressure · Operating mode
- Available commands
- Operating mode · Standby · Fan setpoints · Temperature limits · Humidity limits
- Compatible models
- X-CUBE · X-CUBE Compact · X-CUBE with X-CUBE CONTROL
- Last updated
Registers (183)
168 read, 15 write
| Name | Unit | Access | Address (Hidden until you enter your email) | Function (hidden) | Type (hidden) |
|---|---|---|---|---|---|
| BMS Command Bits | Write | 32768 | FC06 | uint16 | |
| System Mode Command | Write | 32769 | FC06 | uint16 | |
| Outdoor Temperature Input | °C | Write | 32770 | FC06 | int16 |
| Standby Command | Write | 32791 | FC06 | uint16 | |
| Supply Fan Setpoint | Write | 32792 | FC06 | uint16 | |
| Extract Fan Setpoint | Write | ||||
| Minimum Air Temperature Setpoint | °C | Write | |||
| Maximum Air Temperature Setpoint | °C | Write | |||
| Minimum Air Humidity Setpoint | % | Write | |||
| Maximum Air Humidity Setpoint | % | Write | |||
| Cooling Power Demand | % | Write | |||
| Supply Air Temperature Minimum | °C | Write | |||
| Supply Air Temperature Maximum | °C | Write | |||
| Supply Air Humidity Minimum | Write | ||||
| Supply Air Humidity Maximum | Write | ||||
| Supply Air Temperature | °C | Read | |||
| Extract Air Temperature | °C | Read | |||
| Outdoor Air Temperature | °C | Read | |||
| Exhaust Air Temperature | °C | Read | |||
| Outdoor Temperature Value | °C | Read | |||
| Outdoor Air Humidity | % | Read | |||
| Supply Air Humidity | % | Read | |||
| Extract Air Humidity | % | Read | |||
| Exhaust Air Humidity | % | Read | |||
| Supply Duct Pressure | Pa | Read | |||
| Exhaust Duct Pressure | Pa | Read | |||
| VOC Concentration | ppm | Read | |||
| CO2 Concentration | ppm | Read | |||
| Supply Air Temperature Setpoint | °C | Read | |||
| Extract Air Temperature Setpoint | °C | Read | |||
| Operation Mode | Read | ||||
| Event Notification | Read | ||||
| System Status Bits | Read | ||||
| Smoke Detector Bits | Read | ||||
| External Alarm Bits | Read | ||||
| Supply Fan Speed Command | % | Read | |||
| Supply Fan Differential Pressure | Pa | Read | |||
| Supply Airflow | m³/h | Read | |||
| Supply Fan 2 Speed Command | % | Read | |||
| Supply Fan 2 Differential Pressure | Pa | Read | |||
| Supply Airflow 2 | m³/h | Read | |||
| Extract Fan Speed Command | % | Read | |||
| Extract Fan Differential Pressure | Pa | Read | |||
| Extract Airflow | m³/h | Read | |||
| Extract Fan 2 Speed Command | % | Read | |||
| Extract Fan 2 Differential Pressure | Pa | Read | |||
| Extract Airflow 2 | m³/h | Read | |||
| Supply Fan Status Bits | Read | ||||
| Extract Fan Status Bits | Read | ||||
| Outdoor Air Filter Holding Time | h | Read | |||
| Supply Air Filter Holding Time | h | Read | |||
| Extract Air Filter Holding Time | h | Read | |||
| Outdoor Air Filter Operating Time | h | Read | |||
| Supply Air Filter Operating Time | h | Read | |||
| Extract Air Filter Operating Time | h | Read | |||
| Outdoor Air Filter Differential Pressure | Pa | Read | |||
| Supply Air Filter Differential Pressure | Pa | Read | |||
| Extract Air Filter Differential Pressure | Pa | Read | |||
| Outdoor Air Filter 2 Holding Time | h | Read | |||
| Supply Air Filter 2 Holding Time | h | Read | |||
| Extract Air Filter 2 Holding Time | h | Read | |||
| Outdoor Air Filter 2 Operating Time | h | Read | |||
| Supply Air Filter 2 Operating Time | h | Read | |||
| Extract Air Filter 2 Operating Time | h | Read | |||
| Outdoor Air Filter 2 Differential Pressure | Pa | Read | |||
| Supply Air Filter 2 Differential Pressure | Pa | Read | |||
| Extract Air Filter 2 Differential Pressure | Pa | Read | |||
| Filter Status Bits | Read | ||||
| Plate Heat Exchanger Bypass Position | % | Read | |||
| Plate Heat Exchanger Bypass 2 Position | % | Read | |||
| Recovery Air Temperature | °C | Read | |||
| Plate Heat Exchanger Differential Pressure | Read | ||||
| Plate Heat Exchanger Bypass Command | % | Read | |||
| Plate Heat Exchanger Bypass 2 Command | % | Read | |||
| Plate Heat Exchanger Status Bits | Read | ||||
| Heat Recovery Wheel Speed Command | % | Read | |||
| Heat Recovery Wheel Status Bits | Read | ||||
| Cooler Valve Position | % | Read | |||
| Cooler Inlet Temperature | °C | Read | |||
| Cooler Valve Command | % | Read | |||
| Preheater Valve Position | % | Read | |||
| Preheater Outlet Temperature | °C | Read | |||
| Preheater Valve Command | % | Read | |||
| Reheater Valve Position | % | Read | |||
| Reheater Outlet Temperature | °C | Read | |||
| Reheater Valve Command | % | Read | |||
| Cooler Status Bits | Read | ||||
| Preheater Status Bits | Read | ||||
| Reheater Status Bits | Read | ||||
| Outdoor Air Damper Position | % | Read | |||
| Supply Air Damper Position | % | Read | |||
| Extract Air Damper Position | % | Read | |||
| Exhaust Air Damper Position | % | Read | |||
| Recovery Air Damper Position | % | Read | |||
| Outdoor Air 2 Damper Position | % | Read | |||
| Supply Air 2 Damper Position | % | Read | |||
| Extract Air 2 Damper Position | % | Read | |||
| Exhaust Air 2 Damper Position | % | Read | |||
| Recovery Air 2 Damper Position | % | Read | |||
| Supply Fan Damper Position | % | Read | |||
| Extract Fan Damper Position | % | Read | |||
| Supply Fan 2 Damper Position | % | Read | |||
| Extract Fan 2 Damper Position | % | Read | |||
| Outdoor Air Damper Command | % | Read | |||
| Supply Air Damper Command | % | Read | |||
| Extract Air Damper Command | % | Read | |||
| Exhaust Air Damper Command | % | Read | |||
| Recovery Air Damper Command | % | Read | |||
| Outdoor Air 2 Damper Command | % | Read | |||
| Supply Air 2 Damper Command | % | Read | |||
| Extract Air 2 Damper Command | % | Read | |||
| Exhaust Air 2 Damper Command | % | Read | |||
| Recovery Air 2 Damper Command | % | Read | |||
| Supply Fan Damper Command | % | Read | |||
| Extract Fan Damper Command | % | Read | |||
| Supply Fan 2 Damper Command | % | Read | |||
| Extract Fan 2 Damper Command | % | Read | |||
| Damper Communication Error Bits | Read | ||||
| Sensor Communication Error Bits | Read | ||||
| Run Around Coil Status Bits | Read | ||||
| Run Around Coil Status Bits 2 | Read | ||||
| Run Around Coil Pump Speed Command | % | Read | |||
| Run Around Coil Power Valve Command | % | Read | |||
| Run Around Coil Frost Valve Command | % | Read | |||
| Supply Exchanger Inlet Temperature | °C | Read | |||
| Supply Exchanger Outlet Temperature | °C | Read | |||
| Exhaust Exchanger Inlet Temperature | °C | Read | |||
| Exhaust Exchanger Return Temperature | °C | Read | |||
| Brine Temperature | °C | Read | |||
| Brine Volume Flow | m³/h | Read | |||
| Supply Exchanger Thermal Power | kW | Read | |||
| Exhaust Exchanger Thermal Power | kW | Read | |||
| Heating Feed Thermal Power | kW | Read | |||
| Cooling Feed Thermal Power | kW | Read | |||
| Refrigeration Status Bits | Read | ||||
| Fire Damper Closed 1 to 16 | Read | ||||
| Fire Damper Closed 17 to 32 | Read | ||||
| Fire Damper Closed 33 to 48 | Read | ||||
| Fire Damper Closed 49 to 62 | Read | ||||
| Fire Damper Opened 1 to 16 | Read | ||||
| Fire Damper Opened 17 to 32 | Read | ||||
| Fire Damper Opened 33 to 48 | Read | ||||
| Fire Damper Opened 49 to 62 | Read | ||||
| Fire Damper Closing Error 1 to 16 | Read | ||||
| Fire Damper Closing Error 17 to 32 | Read | ||||
| Fire Damper Closing Error 33 to 48 | Read | ||||
| Fire Damper Closing Error 49 to 62 | Read | ||||
| Fire Damper Opening Error 1 to 16 | Read | ||||
| Fire Damper Opening Error 17 to 32 | Read | ||||
| Fire Damper Opening Error 33 to 48 | Read | ||||
| Fire Damper Opening Error 49 to 62 | Read | ||||
| Fire Damper Position Error 1 to 16 | Read | ||||
| Fire Damper Position Error 17 to 32 | Read | ||||
| Fire Damper Position Error 33 to 48 | Read | ||||
| Fire Damper Position Error 49 to 62 | Read | ||||
| Fire Damper Triggered 1 to 16 | Read | ||||
| Fire Damper Triggered 17 to 32 | Read | ||||
| Fire Damper Triggered 33 to 48 | Read | ||||
| Fire Damper Triggered 49 to 62 | Read | ||||
| Supply Fans 3 to 16 On | Read | ||||
| Supply Fans 3 to 16 Error | Read | ||||
| Supply Fans 3 to 16 Communication Error | Read | ||||
| Supply Fans 3 to 16 Repair Switch | Read | ||||
| Extract Fans 3 to 16 On | Read | ||||
| Extract Fans 3 to 16 Error | Read | ||||
| Extract Fans 3 to 16 Communication Error | Read | ||||
| Extract Fans 3 to 16 Repair Switch | Read | ||||
| Electric Preheater Status Bits | Read | ||||
| Electric Preheater Power Command | % | Read | |||
| Electric Reheater Status Bits | Read | ||||
| Electric Reheater Power Command | % | Read | |||
| External Chiller Status Bits | Read | ||||
| External Chiller Power Command | % | Read | |||
| Humidifier Status Bits | Read | ||||
| Humidifier Power Command | % | Read | |||
| Heat Pump 1 Status Bits | Read | ||||
| Heat Pump 1 Power Command | % | Read | |||
| Heat Pump 2 Status Bits | Read | ||||
| Heat Pump 2 Power Command | % | Read | |||
| Heat Pump 3 Status Bits | Read | ||||
| Heat Pump 3 Power Command | % | Read | |||
| Heat Pump 4 Status Bits | Read | ||||
| Heat Pump 4 Power Command | % | Read |
Loading registers…

Send your device list
If a device is not in the library yet, we build the template for free as soon as we have the register data.
Use cases
- Show supply and extract air temperature, humidity and airflow per unit on one dashboard.
- Get an email when the event notification reports a warning or a critical error.
- Track filter differential pressure and running hours to plan filter changes.
- Watch fire damper and smoke detector states across a building from the portal.
- Switch a unit to standby or change its temperature limits remotely.
Installation
Connect the ModbusCloud Gateway to the network of the X-CUBE controller with an Ethernet cable.
Note the IP address of the controller; the factory setting is 192.168.0.180 or 192.168.0.200.
In ModbusCloud, add a Modbus device (TCP) with that IP address, port 502 and unit ID 1, then import this template.
Check that the supply air temperature and operating mode show plausible values.
To write setpoints, release writing in the controller under Management operating level.
Things to watch for
The controller does not answer. What should I check?
Check that the Gateway and the controller are in the same subnet and that you can reach the IP address. Then try unit ID 1 or 255 and port 502; TROX does not publish fixed values. A firewall between both can block port 502.
Why do many registers stay at zero?
The register list covers every option of the X-CUBE. A unit without a humidifier, heat pump, run around coil or fire dampers reports zero for those parts. Hide the registers you do not need on your dashboard.
How do I read the status bits?
Most faults are packed as bits into one register per component, for example all supply fan states in one value. A value of 0 means no bit is set. An alarm rule 'not equal to 0' on such a register reports any fault of that component.
Why does writing a setpoint have no effect?
The controller blocks writes until they are released under Management operating level, and some setpoints can be blocked separately. Writing from the portal also has to be enabled for your Gateway. Temperature setpoints use steps of 0.1 °C.