ABB ACS480
Compact frequency converter: motor readings, energy, faults, start and stop, speed reference and settings.
The ABB ACS480 is a compact general purpose frequency converter that controls fans, pumps, conveyors and compressors in buildings and machines. This Modbus RTU template reads motor speed, current, torque, power, energy and fault codes, and lets you start, stop and change speed and drive parameters from ModbusCloud.
- Protocol
- Modbus RTU
- Connection
- RS485, 19200 baud
- Registers
- 1181, read and write
- Brand
- ABB
- Key readings
- Motor speed · Output frequency · Motor current · Motor torque · Output power · DC voltage · Energy counters · Fault and warning codes
- Available commands
- Control word · Speed reference · Relay outputs · Ramp times · Speed limits · PID setpoints
- Compatible models
- ACS480-04
- Last updated
Registers (1181)
1181 read, 962 write
| Name | Unit | Access | Address (Hidden until you enter your email) | Function (hidden) | Type (hidden) |
|---|---|---|---|---|---|
| Modbus Control Word | Read and write | ||||
| Modbus Reference 1 | Read and write | ||||
| Modbus Reference 2 | Read and write | ||||
| Modbus Status Word | Read | ||||
| Modbus Actual Value 1 | Read | ||||
| Modbus Actual Value 2 | Read | ||||
| Modbus Data I/O 7 | Read and write | ||||
| Modbus Data I/O 8 | Read and write | ||||
| Modbus Data I/O 9 | Read and write | ||||
| Modbus Data I/O 10 | Read and write | ||||
| Modbus Data I/O 11 | Read and write | ||||
| Modbus Data I/O 12 | Read and write | ||||
| Modbus Data I/O 13 | Read and write | ||||
| Modbus Data I/O 14 | Read and write | ||||
| EFB Reset Error Registers | Read and write | ||||
| EFB Error Function Code | Read | ||||
| EFB Error Code | Read | ||||
| EFB Failed Register | Read | ||||
| EFB Last Register Written | Read | ||||
| EFB Last Register Read | Read | ||||
| Motor speed used | rpm | Read | |||
| Motor speed estimated | rpm | Read | |||
| Motor speed % | % | Read | |||
| Output frequency | Hz | Read | |||
| Motor current | A | Read | |||
| Motor current % of motor nom | % | Read | |||
| Motor current % of drive nom | % | Read | |||
| Motor torque | % | Read | |||
| DC voltage | V | Read | |||
| Output voltage | V | Read | |||
| Output power | kW | Read | |||
| Output power % of motor nom | % | Read | |||
| Output power % of drive nom | % | Read | |||
| Motor shaft power | kW | Read | |||
| Inverter GWh counter | Read | ||||
| Inverter MWh counter | MWh | Read | |||
| Inverter kWh counter | kWh | Read | |||
| Flux actual % | % | Read | |||
| Nominal torque scale | Nm | Read | |||
| Current hour kWh | kWh | Read | |||
| Previous hour kWh | kWh | Read | |||
| Current day kWh | kWh | Read | |||
| Previous day kWh | kWh | Read | |||
| Cumulative inverter energy | kWh | Read | |||
| Inverter GWh counter (resettable) | Read | ||||
| Inverter MWh counter (resettable) | MWh | Read | |||
| Inverter kWh counter (resettable) | kWh | Read | |||
| Cumulative inverter energy (resettable) | kWh | Read | |||
| Abs motor speed used | rpm | Read | |||
| Abs motor speed % | % | Read | |||
| Abs output frequency | Hz | Read | |||
| Abs motor torque | % | Read | |||
| Abs output power | kW | Read | |||
| Abs output power % motor nom | % | Read | |||
| Abs output power % drive nom | % | Read | |||
| Abs motor shaft power | kW | Read | |||
| Panel reference | Read | ||||
| Panel reference remote | Read | ||||
| FB A reference 1 | Read | ||||
| FB A reference 2 | Read | ||||
| EFB reference 1 | Read | ||||
| EFB reference 2 | Read | ||||
| Tripping fault | Read | ||||
| Active fault 2 | Read | ||||
| Active fault 3 | Read | ||||
| Active warning 1 | Read | ||||
| Active warning 2 | Read | ||||
| Active warning 3 | Read | ||||
| Latest fault | Read | ||||
| 2nd latest fault | Read | ||||
| 3rd latest fault | Read | ||||
| Latest warning | Read | ||||
| 2nd latest warning | Read | ||||
| 3rd latest warning | Read | ||||
| Event word 1 | Read | ||||
| Event word 1 bit 0 code | Read and write | ||||
| Event word 1 bit 1 code | Read and write | ||||
| Event word 1 bit 2 code | Read and write | ||||
| Event word 1 bit 3 code | Read and write | ||||
| Event word 1 bit 4 code | Read and write | ||||
| Event word 1 bit 5 code | Read and write | ||||
| Event word 1 bit 6 code | Read and write | ||||
| Event word 1 bit 7 code | Read and write | ||||
| Event word 1 bit 8 code | Read and write | ||||
| Event word 1 bit 9 code | Read and write | ||||
| Event word 1 bit 10 code | Read and write | ||||
| Event word 1 bit 11 code | Read and write | ||||
| Event word 1 bit 12 code | Read and write | ||||
| Event word 1 bit 13 code | Read and write | ||||
| Event word 1 bit 14 code | Read and write | ||||
| Event word 1 bit 15 code | Read and write | ||||
| On-time counter | d | Read | |||
| Run-time counter | d | Read | |||
| Hours run | h | Read | |||
| Fan on-time counter | d | Read | |||
| Control board temperature | °C | Read | |||
| Inverter temperature | % | Read | |||
| Diagnostic word 1 | Read | ||||
| Diagnostic word 2 | Read | ||||
| Diagnostic word 3 | Read | ||||
| Motor speed at fault | rpm | Read | |||
| Output frequency at fault | Hz | Read | |||
| DC voltage at fault | V | Read | |||
| Motor current at fault | A | Read | |||
| Motor torque at fault | % | Read | |||
| Main status word at fault | Read | ||||
| DI delayed status at fault | Read | ||||
| Inverter temperature at fault | °C | Read | |||
| Reference used at fault | Hz | Read | |||
| Main control word | Read | ||||
| Main status word | Read | ||||
| Drive status word 1 | Read | ||||
| Drive status word 2 | Read | ||||
| Start inhibit status word | Read | ||||
| Speed control status word | Read | ||||
| Constant speed status word | Read | ||||
| Drive status word 3 | Read | ||||
| MSW bit 10 selection | Read | ||||
| MSW bit 11 selection | Read | ||||
| MSW bit 12 selection | Read | ||||
| MSW bit 13 selection | Read | ||||
| MSW bit 14 selection | Read | ||||
| Drive rating id | Read | ||||
| Firmware name | Read | ||||
| Firmware version | Read | ||||
| Loading package name | Read | ||||
| Loading package version | Read | ||||
| Cpu usage | % | Read | |||
| Customization package name | Read | ||||
| Customization package version | Read | ||||
| Adaptive program status | Read | ||||
| AP sequence state | Read | ||||
| Drive configuration | Read | ||||
| Drive configuration 2 | Read | ||||
| DI status | Read | ||||
| DI delayed status | Read | ||||
| DI force selection | Read and write | ||||
| DI forced data | Read and write | ||||
| DI1 ON delay | s | Read and write | |||
| DI1 OFF delay | s | Read and write | |||
| DI2 ON delay | s | Read and write | |||
| DI2 OFF delay | s | Read and write | |||
| DI3 ON delay | s | Read and write | |||
| DI3 OFF delay | s | Read and write | |||
| DI4 ON delay | s | Read and write | |||
| DI4 OFF delay | s | Read and write | |||
| DI5 ON delay | s | Read and write | |||
| DI5 OFF delay | s | Read and write | |||
| DI6 ON delay | s | Read and write | |||
| DI6 OFF delay | s | Read and write | |||
| RO status | Read and write | ||||
| RO force selection | Read and write | ||||
| RO forced data | Read and write | ||||
| RO1 source | Read and write | ||||
| RO1 ON delay | s | Read and write | |||
| RO1 OFF delay | s | Read and write | |||
| RO2 source | Read and write | ||||
| RO2 ON delay | s | Read and write | |||
| RO2 OFF delay | s | Read and write | |||
| RO3 source | Read and write | ||||
| RO3 ON delay | s | Read and write | |||
| RO3 OFF delay | s | Read and write | |||
| RO/DIO control word | Read and write | ||||
| DIO delayed status | Read | ||||
| DIO force selection | Read and write | ||||
| DIO force data | Read and write | ||||
| DIO1 configuration | Read and write | ||||
| DIO1 output source | Read and write | ||||
| DIO1 ON delay | s | Read and write | |||
| DIO1 OFF delay | s | Read and write | |||
| DI4 configuration | Read and write | ||||
| DI5 configuration | Read and write | ||||
| Freq in 1 actual value | Hz | Read | |||
| Freq in 1 scaled value | Read | ||||
| Freq in 1 min | Hz | Read and write | |||
| Freq in 1 max | Hz | Read and write | |||
| Freq in 1 at scaled min | Read and write | ||||
| Freq in 1 at scaled max | Read and write | ||||
| AI force selection | Read and write | ||||
| AI supervision function | Read and write | ||||
| AI supervision selection | Read and write | ||||
| AI1 actual value | Read | ||||
| AI1 scaled value | Read | ||||
| AI1 forced value | Read and write | ||||
| AI1 unit selection | Read and write | ||||
| AI1 filter time | s | Read and write | |||
| AI1 min | Read and write | ||||
| AI1 max | Read and write | ||||
| AI1 scaled at AI1 min | Read and write | ||||
| AI1 scaled at AI1 max | Read and write | ||||
| AI2 actual value | Read | ||||
| AI2 scaled value | Read | ||||
| AI2 forced value | Read and write | ||||
| AI2 unit selection | Read and write | ||||
| AI2 filter time | s | Read and write | |||
| AI2 min | Read and write | ||||
| AI2 max | Read and write | ||||
| AI2 scaled at AI2 min | Read and write | ||||
| AI2 scaled at AI2 max | Read and write | ||||
| AO force selection | Read and write | ||||
| AO1 actual value | mA | Read | |||
| AO1 source | Read and write | ||||
| AO1 forced value | mA | Read and write | |||
| AO1 unit selection | Read and write | ||||
| AO1 filter time | s | Read and write | |||
| AO1 source min | Read and write | ||||
| AO1 source max | Read and write | ||||
| AO1 out at AO1 src min | mA | Read and write | |||
| AO1 out at AO1 src max | mA | Read and write | |||
| AO2 actual value | mA | Read | |||
| AO2 source | Read and write | ||||
| AO2 forced value | mA | Read and write | |||
| AO2 filter time | s | Read and write | |||
| AO2 source min | Read and write | ||||
| AO2 source max | Read and write | ||||
| AO2 out at AO2 src min | mA | Read and write | |||
| AO2 out at AO2 src max | mA | Read and write | |||
| AO1 data storage | Read and write | ||||
| AO2 data storage | Read and write | ||||
| Extension module type | Read and write | ||||
| Detected extension module | Read and write | ||||
| RO status (15.04) | Read | ||||
| RO force selection (15.05) | Read and write | ||||
| RO forced data (15.06) | Read and write | ||||
| RO4 source | Read and write | ||||
| RO4 ON delay | s | Read and write | |||
| RO4 OFF delay | s | Read and write | |||
| RO5 source | Read and write | ||||
| RO5 ON delay | s | Read and write | |||
| RO5 OFF delay | s | Read and write | |||
| RO6 source | Read and write | ||||
| RO6 ON delay | s | Read and write | |||
| RO6 OFF delay | s | Read and write | |||
| RO7 source | Read and write | ||||
| RO7 ON delay | s | Read and write | |||
| RO7 OFF delay | s | Read and write | |||
| Actual operation mode | Read | ||||
| Ext1/Ext2 selection | Read and write | ||||
| Ext1 control mode | Read and write | ||||
| Ext2 control mode | Read and write | ||||
| Local control mode | Read and write | ||||
| Local control disable | Read and write | ||||
| Ext1 commands | Read and write | ||||
| Ext1 start trigger type | Read and write | ||||
| Ext1 in1 source | Read and write | ||||
| Ext1 in2 source | Read and write | ||||
| Ext1 in3 source | Read and write | ||||
| Ext2 commands | Read and write | ||||
| Ext2 start trigger type | Read and write | ||||
| Ext2 in1 source | Read and write | ||||
| Ext2 in2 source | Read and write | ||||
| Ext2 in3 source | Read and write | ||||
| Run enable stop mode | Read and write | ||||
| Run enable 1 source | Read and write | ||||
| Enable start command | Read and write | ||||
| Direction | Read and write | ||||
| Enable to rotate | Read and write | ||||
| Jogging enable | Read and write | ||||
| Jogging 1 start source | Read and write | ||||
| Jogging 2 start source | Read and write | ||||
| Start mode | Read and write | ||||
| Magnetization time | ms | Read and write | |||
| Stop mode | Read and write | ||||
| Emergency stop mode | Read and write | ||||
| Emergency stop source | Read and write | ||||
| Zero speed limit | rpm | Read and write | |||
| Zero speed delay | ms | Read and write | |||
| DC current control | Read and write | ||||
| DC hold speed | rpm | Read and write | |||
| DC current reference | % | Read and write | |||
| Post magnetization time | s | Read and write | |||
| Pre-heating input source | Read and write | ||||
| Pre-heating time delay | s | Read and write | |||
| Pre-heating current | % | Read and write | |||
| Auto restart time | s | Read and write | |||
| Scalar start mode | Read and write | ||||
| DC hold frequency | Hz | Read and write | |||
| Start delay | s | Read and write | |||
| Smooth start | Read and write | ||||
| Smooth start current | % | Read and write | |||
| Smooth start speed | % | Read and write | |||
| Torque boost current | % | Read and write | |||
| Torque boost time | s | Read and write | |||
| Speed compensated stop mode | Read and write | ||||
| Speed comp stop delay | s | Read and write | |||
| Speed comp stop threshold | % | Read and write | |||
| Force auto restart | Read and write | ||||
| Preheating power | kW | Read and write | |||
| Preheating unit | Read and write | ||||
| Speed ref unlimited | rpm | Read | |||
| Ext1 speed ref1 | Read and write | ||||
| Ext1 speed ref2 | Read and write | ||||
| Ext1 speed function | Read and write | ||||
| Ext2 speed ref1 | Read and write | ||||
| Ext2 speed ref2 | Read and write | ||||
| Ext2 speed function | Read and write | ||||
| Constant speed function | Read and write | ||||
| Constant speed sel1 | Read and write | ||||
| Constant speed sel2 | Read and write | ||||
| Constant speed sel3 | Read and write | ||||
| Constant speed 1 | rpm | Read and write | |||
| Constant speed 2 | rpm | Read and write | |||
| Constant speed 3 | rpm | Read and write | |||
| Constant speed 4 | rpm | Read and write | |||
| Constant speed 5 | rpm | Read and write | |||
| Constant speed 6 | rpm | Read and write | |||
| Constant speed 7 | rpm | Read and write | |||
| Speed ref safe | rpm | Read and write | |||
| Jogging 1 ref | rpm | Read and write | |||
| Jogging 2 ref | rpm | Read and write | |||
| Critical speed function | Read and write | ||||
| Critical speed 1 low | rpm | Read and write | |||
| Critical speed 1 high | rpm | Read and write | |||
| Critical speed 2 low | rpm | Read and write | |||
| Critical speed 2 high | rpm | Read and write | |||
| Critical speed 3 low | rpm | Read and write | |||
| Critical speed 3 high | rpm | Read and write | |||
| Motor potentiometer function | Read and write | ||||
| Motor potentiometer initial value | Read and write | ||||
| Motor potentiometer up source | Read and write | ||||
| Motor potentiometer down | Read and write | ||||
| Motor potentiometer ramp time | s | Read and write | |||
| Motor potentiometer min value | Read and write | ||||
| Motor potentiometer max value | Read and write | ||||
| Motor potentiometer ref act | Read | ||||
| Speed reference act 6 | rpm | Read | |||
| Speed reference act 7 | rpm | Read | |||
| Speed ref ramp input | rpm | Read | |||
| Speed ref ramp output | rpm | Read | |||
| Ramp set selection | Read and write | ||||
| Acceleration time 1 | s | Read and write | |||
| Deceleration time 1 | s | Read and write | |||
| Acceleration time 2 | s | Read and write | |||
| Deceleration time 2 | s | Read and write | |||
| Acc time jogging | s | Read and write | |||
| Dec time jogging | s | Read and write | |||
| Emergency stop time | s | Read and write | |||
| Variable slope enable | Read and write | ||||
| Variable slope rate | ms | Read and write | |||
| Shape time 1 | s | Read and write | |||
| Shape time 2 | s | Read and write | |||
| Used speed reference | rpm | Read | |||
| Used speed feedback | rpm | Read | |||
| Speed error filtered | rpm | Read | |||
| Speed error inverted | rpm | Read | |||
| Speed correction | rpm | Read and write | |||
| Speed error filter time | ms | Read and write | |||
| Torque reference speed control | % | Read | |||
| Speed proportional gain | Read and write | ||||
| Speed integration time | s | Read and write | |||
| Speed derivation time | s | Read and write | |||
| Derivation filter time | ms | Read and write | |||
| Acc comp derivation time | s | Read and write | |||
| Acc comp filter time | ms | Read and write | |||
| Proportional gain em stop | Read and write | ||||
| Speed controller autotune | Read and write | ||||
| Speed controller autotune mode | Read and write | ||||
| Mechanical time constant | s | Read and write | |||
| Autotune torque step | % | Read and write | |||
| Autotune speed step | % | Read and write | |||
| Autotune repeat times | Read and write | ||||
| Torque prop reference | % | Read | |||
| Torque integral reference | % | Read | |||
| Torque deriv reference | % | Read | |||
| Torque acc compensation | % | Read | |||
| Torque reference to TC | % | Read | |||
| Torque reference used | % | Read | |||
| Minimum torque ref | % | Read and write | |||
| Maximum torque ref | % | Read and write | |||
| Torque ref1 source | Read and write | ||||
| Torque ref2 source | Read and write | ||||
| Torque ref1 function | Read and write | ||||
| Torque ref1/2 selection | Read and write | ||||
| Torque ref filter time | s | Read and write | |||
| Torque ramp up time | s | Read and write | |||
| Torque ramp down time | s | Read and write | |||
| Torque reversal | Read and write | ||||
| Torque sel torque in | Read and write | ||||
| Torque sel speed in | Read and write | ||||
| Torque reference act 1 | % | Read | |||
| Torque reference act 2 | % | Read | |||
| Torque reference act 3 | % | Read | |||
| Torque reference act 4 | % | Read | |||
| Torque ref ramp out | % | Read | |||
| Torque reference act 5 | % | Read | |||
| Rush control gain | Read and write | ||||
| Rush control integration time | s | Read and write | |||
| Frequency ref ramp input | Hz | Read | |||
| Frequency ref ramp output | Hz | Read | |||
| Ext1 frequency ref1 | Read and write | ||||
| Ext1 frequency ref2 | Read and write | ||||
| Ext1 frequency function | Read and write | ||||
| Ext2 frequency ref1 | Read and write | ||||
| Ext2 frequency ref2 | Read and write | ||||
| Ext2 frequency function | Read and write | ||||
| Constant frequency function | Read and write | ||||
| Constant frequency sel1 | Read and write | ||||
| Constant frequency sel2 | Read and write | ||||
| Constant frequency sel3 | Read and write | ||||
| Constant frequency 1 | Hz | Read and write | |||
| Constant frequency 2 | Hz | Read and write | |||
| Constant frequency 3 | Hz | Read and write | |||
| Constant frequency 4 | Hz | Read and write | |||
| Constant frequency 5 | Hz | Read and write | |||
| Constant frequency 6 | Hz | Read and write | |||
| Constant frequency 7 | Hz | Read and write | |||
| Frequency ref safe | Hz | Read and write | |||
| Jogging 1 frequency ref | Hz | Read and write | |||
| Jogging 2 frequency ref | Hz | Read and write | |||
| Critical frequency function | Read and write | ||||
| Critical frequency 1 low | Hz | Read and write | |||
| Critical frequency 1 high | Hz | Read and write | |||
| Critical frequency 2 low | Hz | Read and write | |||
| Critical frequency 2 high | Hz | Read and write | |||
| Critical frequency 3 low | Hz | Read and write | |||
| Critical frequency 3 high | Hz | Read and write | |||
| Freq ramp set selection | Read and write | ||||
| Freq acceleration time 1 | s | Read and write | |||
| Freq deceleration time 1 | s | Read and write | |||
| Freq acceleration time 2 | s | Read and write | |||
| Freq deceleration time 2 | s | Read and write | |||
| Freq ramp in zero source | Read and write | ||||
| Shape time 1 (28.82) | s | Read and write | |||
| Shape time 2 (28.83) | s | Read and write | |||
| Frequency ref act 3 | Hz | Read | |||
| Frequency ref act 7 | Hz | Read | |||
| Frequency ref unlimited | Hz | Read | |||
| Limit word 1 | Read | ||||
| Torque limit status | Read | ||||
| Minimum speed | rpm | Read and write | |||
| Maximum speed | rpm | Read and write | |||
| Minimum frequency | Hz | Read and write | |||
| Maximum frequency | Hz | Read and write | |||
| Maximum current | A | Read and write | |||
| Torq lim sel | Read and write | ||||
| Minimum torque 1 | % | Read and write | |||
| Maximum torque 1 | % | Read and write | |||
| Min torque 2 source | Read and write | ||||
| Max torque 2 source | Read and write | ||||
| Minimum torque 2 | % | Read and write | |||
| Maximum torque 2 | % | Read and write | |||
| Power motoring limit | % | Read and write | |||
| Power generating limit | % | Read and write | |||
| Overvoltage control | Read and write | ||||
| Undervoltage control | Read and write | ||||
| Thermal current limitation | Read and write | ||||
| Speed limit selection | Read and write | ||||
| Minimum speed source | Read and write | ||||
| Maximum speed source | Read and write | ||||
| External event 1 source | Read and write | ||||
| External event 1 type | Read and write | ||||
| External event 2 source | Read and write | ||||
| External event 2 type | Read and write | ||||
| External event 3 source | Read and write | ||||
| External event 3 type | Read and write | ||||
| External event 4 source | Read and write | ||||
| External event 4 type | Read and write | ||||
| External event 5 source | Read and write | ||||
| External event 5 type | Read and write | ||||
| Fault reset selection | Read and write | ||||
| Autoreset selection | Read and write | ||||
| Selectable fault | Read and write | ||||
| Number of trials | Read and write | ||||
| Total trials time | s | Read and write | |||
| Delay time | s | Read and write | |||
| Motor phase loss | Read and write | ||||
| Supply phase loss | Read and write | ||||
| STO indication run/stop | Read and write | ||||
| Wiring or earth fault | Read and write | ||||
| Stall function | Read and write | ||||
| Stall current limit | % | Read and write | |||
| Stall speed limit | rpm | Read and write | |||
| Stall frequency limit | Hz | Read and write | |||
| Stall time | s | Read and write | |||
| Overspeed trip margin | rpm | Read and write | |||
| Frequency trip margin | Hz | Read and write | |||
| Emergency ramp supervision | % | Read and write | |||
| Emergency ramp supervision delay | s | Read and write | |||
| Main fan fault function | Read and write | ||||
| Supervision status | Read and write | ||||
| Supervision 1 function | Read and write | ||||
| Supervision 1 action | Read and write | ||||
| Supervision 1 signal | Read and write | ||||
| Supervision 1 filter time | s | Read and write | |||
| Supervision 1 low | Read and write | ||||
| Supervision 1 high | Read and write | ||||
| Supervision 1 hysteresis | Read and write | ||||
| Supervision 2 function | Read and write | ||||
| Supervision 2 action | Read and write | ||||
| Supervision 2 signal | Read and write | ||||
| Supervision 2 filter time | s | Read and write | |||
| Supervision 2 low | Read and write | ||||
| Supervision 2 high | Read and write | ||||
| Supervision 2 hysteresis | Read and write | ||||
| Supervision 3 function | Read and write | ||||
| Supervision 3 action | Read and write | ||||
| Supervision 3 signal | Read and write | ||||
| Supervision 3 filter time | s | Read and write | |||
| Supervision 3 low | Read and write | ||||
| Supervision 3 high | Read and write | ||||
| Supervision 3 hysteresis | Read and write | ||||
| Supervision 4 function | Read and write | ||||
| Supervision 4 action | Read and write | ||||
| Supervision 4 signal | Read and write | ||||
| Supervision 4 filter time | s | Read and write | |||
| Supervision 4 low | Read and write | ||||
| Supervision 4 high | Read and write | ||||
| Supervision 4 hysteresis | Read and write | ||||
| Supervision 5 function | Read and write | ||||
| Supervision 5 action | Read and write | ||||
| Supervision 5 signal | Read and write | ||||
| Supervision 5 filter time | s | Read and write | |||
| Supervision 5 low | Read and write | ||||
| Supervision 5 high | Read and write | ||||
| Supervision 5 hysteresis | Read and write | ||||
| Supervision 6 function | Read and write | ||||
| Supervision 6 action | Read and write | ||||
| Supervision 6 signal | Read and write | ||||
| Supervision 6 filter time | s | Read and write | |||
| Supervision 6 low | Read and write | ||||
| Supervision 6 high | Read and write | ||||
| Supervision 6 hysteresis | Read and write | ||||
| Timed functions status | Read | ||||
| Timer status | Read | ||||
| Season/exception day status | Read | ||||
| Timed functions enable | Read and write | ||||
| Timer 1 configuration | Read and write | ||||
| Timer 1 start time | s | Read and write | |||
| Timer 1 duration | min | Read and write | |||
| Timer 2 configuration | Read and write | ||||
| Timer 2 start time | s | Read and write | |||
| Timer 2 duration | min | Read and write | |||
| Timer 3 configuration | Read and write | ||||
| Timer 3 start time | s | Read and write | |||
| Timer 3 duration | min | Read and write | |||
| Timer 4 configuration | Read and write | ||||
| Timer 4 start time | s | Read and write | |||
| Timer 4 duration | min | Read and write | |||
| Timer 5 configuration | Read and write | ||||
| Timer 5 start time | s | Read and write | |||
| Timer 5 duration | min | Read and write | |||
| Timer 6 configuration | Read and write | ||||
| Timer 6 start time | s | Read and write | |||
| Timer 6 duration | min | Read and write | |||
| Timer 7 configuration | Read and write | ||||
| Timer 7 start time | s | Read and write | |||
| Timer 7 duration | min | Read and write | |||
| Timer 8 configuration | Read and write | ||||
| Timer 8 start time | s | Read and write | |||
| Timer 8 duration | min | Read and write | |||
| Timer 9 configuration | Read and write | ||||
| Timer 9 start time | s | Read and write | |||
| Timer 9 duration | min | Read and write | |||
| Timer 10 configuration | Read and write | ||||
| Timer 10 start time | s | Read and write | |||
| Timer 10 duration | min | Read and write | |||
| Timer 11 configuration | Read and write | ||||
| Timer 11 start time | s | Read and write | |||
| Timer 11 duration | min | Read and write | |||
| Timer 12 configuration | Read and write | ||||
| Timer 12 start time | s | Read and write | |||
| Timer 12 duration | min | Read and write | |||
| Season 1 start date | Read and write | ||||
| Season 2 start date | Read and write | ||||
| Season 3 start date | Read and write | ||||
| Season 4 start date | Read and write | ||||
| Number of active exceptions | Read and write | ||||
| Exception types | Read and write | ||||
| Exception 1 start | Read and write | ||||
| Exception 1 length | d | Read and write | |||
| Exception 2 start | Read and write | ||||
| Exception 2 length | d | Read and write | |||
| Exception 3 start | Read and write | ||||
| Exception 3 length | d | Read and write | |||
| Exception day 4 | Read and write | ||||
| Exception day 5 | Read and write | ||||
| Exception day 6 | Read and write | ||||
| Exception day 7 | Read and write | ||||
| Exception day 8 | Read and write | ||||
| Exception day 9 | Read and write | ||||
| Exception day 10 | Read and write | ||||
| Exception day 11 | Read and write | ||||
| Exception day 12 | Read and write | ||||
| Exception day 13 | Read and write | ||||
| Exception day 14 | Read and write | ||||
| Exception day 15 | Read and write | ||||
| Exception day 16 | Read and write | ||||
| Motor estimated temperature | °C | Read | |||
| Measured temperature 1 | Read | ||||
| Measured temperature 2 | Read | ||||
| Motor overload level | % | Read and write | |||
| Temperature 1 source | Read and write | ||||
| Temperature 1 fault limit | Read and write | ||||
| Temperature 1 warning limit | Read and write | ||||
| Temperature 1 AI source | Read and write | ||||
| Temperature 2 source | Read and write | ||||
| Temperature 2 fault limit | Read and write | ||||
| Temperature 2 warning limit | Read and write | ||||
| Temperature 2 AI source | Read and write | ||||
| Motor ambient temperature | °C | Read and write | |||
| Motor load curve | % | Read and write | |||
| Zero speed load | % | Read and write | |||
| Break point | Hz | Read and write | |||
| Motor nominal temperature rise | °C | Read and write | |||
| Motor thermal time constant | s | Read and write | |||
| Motor overload action | Read and write | ||||
| Motor overload class | Read and write | ||||
| PVL signal source | Read and write | ||||
| PVL filter time | s | Read and write | |||
| AL2 signal source | Read and write | ||||
| AL2 signal scaling | Read and write | ||||
| Reset loggers | Read and write | ||||
| PVL peak value | Read and write | ||||
| PVL peak date | Read and write | ||||
| PVL peak time | Read and write | ||||
| PVL current at peak | A | Read and write | |||
| PVL DC voltage at peak | V | Read and write | |||
| PVL speed at peak | rpm | Read and write | |||
| PVL reset date | Read and write | ||||
| PVL reset time | Read and write | ||||
| AL1 0 to 10% | % | Read and write | |||
| AL1 10 to 20% | % | Read and write | |||
| AL1 20 to 30% | % | Read and write | |||
| AL1 30 to 40% | % | Read and write | |||
| AL1 40 to 50% | % | Read and write | |||
| AL1 50 to 60% | % | Read and write | |||
| AL1 60 to 70% | % | Read and write | |||
| AL1 70 to 80% | % | Read and write | |||
| AL1 80 to 90% | % | Read and write | |||
| AL1 over 90% | % | Read and write | |||
| AL2 0 to 10% | % | Read and write | |||
| AL2 10 to 20% | % | Read and write | |||
| AL2 20 to 30% | % | Read and write | |||
| AL2 30 to 40% | % | Read and write | |||
| AL2 40 to 50% | % | Read and write | |||
| AL2 50 to 60% | % | Read and write | |||
| AL2 60 to 70% | % | Read and write | |||
| AL2 70 to 80% | % | Read and write | |||
| AL2 80 to 90% | % | Read and write | |||
| AL2 over 90% | % | Read and write | |||
| AL2 reset date | Read and write | ||||
| AL2 reset time | Read and write | ||||
| ULC output status word | Read | ||||
| ULC supervision signal | Read and write | ||||
| ULC overload actions | Read and write | ||||
| ULC underload actions | Read and write | ||||
| ULC speed table point 1 | rpm | Read and write | |||
| ULC speed table point 2 | rpm | Read and write | |||
| ULC speed table point 3 | rpm | Read and write | |||
| ULC speed table point 4 | rpm | Read and write | |||
| ULC speed table point 5 | rpm | Read and write | |||
| ULC frequency table point 1 | Hz | Read and write | |||
| ULC frequency table point 2 | Hz | Read and write | |||
| ULC frequency table point 3 | Hz | Read and write | |||
| ULC frequency table point 4 | Hz | Read and write | |||
| ULC frequency table point 5 | Hz | Read and write | |||
| ULC underload point 1 | % | Read and write | |||
| ULC underload point 2 | % | Read and write | |||
| ULC underload point 3 | % | Read and write | |||
| ULC underload point 4 | % | Read and write | |||
| ULC underload point 5 | % | Read and write | |||
| ULC overload point 1 | % | Read and write | |||
| ULC overload point 2 | % | Read and write | |||
| ULC overload point 3 | % | Read and write | |||
| ULC overload point 4 | % | Read and write | |||
| ULC overload point 5 | % | Read and write | |||
| ULC overload timer | s | Read and write | |||
| ULC underload timer | s | Read and write | |||
| Process PID output actual | % | Read | |||
| Process PID feedback actual | Read | ||||
| Process PID setpoint actual | Read | ||||
| Process PID deviation actual | Read | ||||
| Process PID trim output act | Read | ||||
| Process PID status word | Read | ||||
| Process PID operation mode | Read and write | ||||
| Set 1 feedback 1 source | Read and write | ||||
| Set 1 feedback 2 source | Read and write | ||||
| Set 1 feedback function | Read and write | ||||
| Set 1 feedback filter time | s | Read and write | |||
| Set 1 setpoint scaling | Read and write | ||||
| Set 1 output scaling | Read and write | ||||
| Set 1 setpoint 1 source | Read and write | ||||
| Set 1 setpoint 2 source | Read and write | ||||
| Set 1 setpoint function | Read and write | ||||
| Set 1 internal setpoint sel1 | Read and write | ||||
| Set 1 internal setpoint sel2 | Read and write | ||||
| Set 1 internal setpoint 1 | Read and write | ||||
| Set 1 internal setpoint 2 | Read and write | ||||
| Set 1 internal setpoint 3 | Read and write | ||||
| Set 1 internal setpoint 0 | Read and write | ||||
| Set 1 setpoint min | Read and write | ||||
| Set 1 setpoint max | Read and write | ||||
| Set 1 setpoint increase time | s | Read and write | |||
| Set 1 setpoint decrease time | s | Read and write | |||
| Set 1 setpoint freeze enable | Read and write | ||||
| Set 1 deviation inversion | Read and write | ||||
| Set 1 gain | Read and write | ||||
| Set 1 integration time | s | Read and write | |||
| Set 1 derivation time | s | Read and write | |||
| Set 1 derivation filter time | s | Read and write | |||
| Set 1 output min | Read and write | ||||
| Set 1 output max | Read and write | ||||
| Set 1 output freeze enable | Read and write | ||||
| Set 1 deadband range | Read and write | ||||
| Set 1 deadband delay | s | Read and write | |||
| Set 1 sleep level | Read and write | ||||
| Set 1 sleep delay | s | Read and write | |||
| Set 1 sleep boost time | s | Read and write | |||
| Set 1 sleep boost step | Read and write | ||||
| Set 1 wake-up deviation | Read and write | ||||
| Set 1 wake-up delay | s | Read and write | |||
| Set 1 tracking mode | Read and write | ||||
| Set 1 tracking ref selection | Read and write | ||||
| Set 1 trim mode | Read and write | ||||
| Set 1 trim selection | Read and write | ||||
| Set 1 trimmed ref pointer | Read and write | ||||
| Set 1 trim mix | Read and write | ||||
| Set 1 trim adjust | Read and write | ||||
| Set 1 trim source | Read and write | ||||
| PID set1/set2 selection | Read and write | ||||
| Set 1 increase prevention | Read and write | ||||
| Set 1 decrease prevention | Read and write | ||||
| Set 1 PID activation source | Read and write | ||||
| Setpoint scaling actual | Read and write | ||||
| PID internal setpoint actual | Read | ||||
| Set 1 units | Read and write | ||||
| Set 1 PID output min source | Read and write | ||||
| Set 1 PID output max source | Read and write | ||||
| Set 1 setpoint multiplier | Read and write | ||||
| Set 1 feedback multiplier | Read and write | ||||
| Feedback data storage | Read and write | ||||
| Setpoint data storage | Read and write | ||||
| Process PID output % | % | Read and write | |||
| Process PID feedback % | % | Read and write | |||
| Process PID setpoint % | % | Read and write | |||
| Process PID deviation % | % | Read and write | |||
| Set 2 feedback 1 source | Read and write | ||||
| Set 2 feedback 2 source | Read and write | ||||
| Set 2 feedback function | Read and write | ||||
| Set 2 feedback filter time | s | Read and write | |||
| Set 2 setpoint scaling | Read and write | ||||
| Set 2 output scaling | Read and write | ||||
| Set 2 setpoint 1 source | Read and write | ||||
| Set 2 setpoint 2 source | Read and write | ||||
| Set 2 setpoint function | Read and write | ||||
| Set 2 internal setpoint sel1 | Read and write | ||||
| Set 2 internal setpoint sel2 | Read and write | ||||
| Set 2 internal setpoint 1 | Read and write | ||||
| Set 2 internal setpoint 2 | Read and write | ||||
| Set 2 internal setpoint 3 | Read and write | ||||
| Set 2 internal setpoint 0 | Read and write | ||||
| Set 2 setpoint min | Read and write | ||||
| Set 2 setpoint max | Read and write | ||||
| Set 2 setpoint increase time | s | Read and write | |||
| Set 2 setpoint decrease time | s | Read and write | |||
| Set 2 setpoint freeze enable | Read and write | ||||
| Set 2 deviation inversion | Read and write | ||||
| Set 2 gain | Read and write | ||||
| Set 2 integration time | s | Read and write | |||
| Set 2 derivation time | s | Read and write | |||
| Set 2 derivation filter time | s | Read and write | |||
| Set 2 output min | Read and write | ||||
| Set 2 output max | Read and write | ||||
| Set 2 output freeze enable | Read and write | ||||
| Set 2 deadband range | Read and write | ||||
| Set 2 deadband delay | s | Read and write | |||
| Set 2 sleep level | Read and write | ||||
| Set 2 sleep delay | s | Read and write | |||
| Set 2 sleep boost time | s | Read and write | |||
| Set 2 sleep boost step | Read and write | ||||
| Set 2 wake-up deviation | Read and write | ||||
| Set 2 wake-up delay | s | Read and write | |||
| Set 2 tracking mode | Read and write | ||||
| Set 2 tracking ref selection | Read and write | ||||
| Set 2 trim mode | Read and write | ||||
| Set 2 trim selection | Read and write | ||||
| Set 2 trimmed ref pointer | Read and write | ||||
| Set 2 trim mix | Read and write | ||||
| Set 2 trim adjust | Read and write | ||||
| Set 2 trim source | Read and write | ||||
| Set 2 increase prevention | Read and write | ||||
| Set 2 decrease prevention | Read and write | ||||
| Set 2 PID activation source | Read and write | ||||
| Set 2 units | Read and write | ||||
| Set 2 PID output min source | Read and write | ||||
| Set 2 PID output max source | Read and write | ||||
| Set 2 setpoint multiplier | Read and write | ||||
| Set 2 feedback multiplier | Read and write | ||||
| Braking resistor temperature | % | Read | |||
| Brake chopper function | Read and write | ||||
| Brake chopper run enable | Read and write | ||||
| Brake resistor thermal tc | s | Read and write | |||
| Brake resistor Pmax cont | kW | Read and write | |||
| Brake resistance | Ω | Read and write | |||
| Brake resistor fault limit | % | Read and write | |||
| Brake resistor warning limit | % | Read and write | |||
| Brake control status | Read | ||||
| Brake control enable | Read and write | ||||
| Brake open delay | s | Read and write | |||
| Brake close delay | s | Read and write | |||
| Brake close level | rpm | Read and write | |||
| Saved GW hours | Read | ||||
| Saved MW hours | MWh | Read | |||
| Saved kW hours | kWh | Read | |||
| Saved energy | kWh | Read | |||
| Saved money x1000 | Read | ||||
| Saved money | Read | ||||
| Saved amount | Read | ||||
| CO2 reduction in kilotons | Read | ||||
| CO2 reduction in tons | t | Read | |||
| Total saved CO2 | t | Read | |||
| Energy optimizer | Read and write | ||||
| Energy tariff 1 | Read and write | ||||
| Energy tariff 2 | Read and write | ||||
| Tariff selection | Read and write | ||||
| CO2 conversion factor | Read and write | ||||
| Comparison power | kW | Read and write | |||
| Energy calculations reset | Read and write | ||||
| Hourly peak power value | kW | Read and write | |||
| Hourly peak power time | Read and write | ||||
| Hourly total energy (resettable) | kWh | Read and write | |||
| Daily peak power value (resettable) | kW | Read and write | |||
| Daily peak power time | Read and write | ||||
| Daily total energy (resettable) | kWh | Read and write | |||
| Last day total energy | kWh | Read and write | |||
| Monthly peak power value (resettable) | kW | Read and write | |||
| Monthly peak power date | Read and write | ||||
| Monthly peak power time | Read and write | ||||
| Monthly total energy (resettable) | kWh | Read and write | |||
| Last month total energy | kWh | Read and write | |||
| Lifetime peak power value | kW | Read and write | |||
| Lifetime peak power date | Read and write | ||||
| Lifetime peak power time | Read and write | ||||
| Speed scaling | rpm | Read and write | |||
| Frequency scaling | Hz | Read and write | |||
| Torque scaling | % | Read and write | |||
| Power scaling | Read and write | ||||
| Current scaling | A | Read and write | |||
| Speed ref zero scaling | rpm | Read and write | |||
| Frequency ref zero scaling | Hz | Read and write | |||
| Filter time motor speed | ms | Read and write | |||
| Filter time output frequency | ms | Read and write | |||
| Filter time motor torque | ms | Read and write | |||
| Filter time power | ms | Read and write | |||
| At speed hysteresis | rpm | Read and write | |||
| At frequency hysteresis | Hz | Read and write | |||
| At torque hysteresis | % | Read and write | |||
| Above speed limit | rpm | Read and write | |||
| Above frequency limit | Hz | Read and write | |||
| Above torque limit | % | Read and write | |||
| KWh pulse scaling | kWh | Read and write | |||
| Power decimals | Read and write | ||||
| Current decimals | Read and write | ||||
| Data storage 1 real32 | Read and write | ||||
| Data storage 2 real32 | Read and write | ||||
| Data storage 3 real32 | Read and write | ||||
| Data storage 4 real32 | Read and write | ||||
| Data storage 1 int32 | Read and write | ||||
| Data storage 2 int32 | Read and write | ||||
| Data storage 3 int32 | Read and write | ||||
| Data storage 4 int32 | Read and write | ||||
| Data storage 1 int16 | Read and write | ||||
| Data storage 2 int16 | Read and write | ||||
| Data storage 3 int16 | Read and write | ||||
| Data storage 4 int16 | Read and write | ||||
| Node ID number | Read and write | ||||
| Baud rate | Read and write | ||||
| Communication loss time | s | Read and write | |||
| Communication loss action | Read and write | ||||
| Refresh settings | Read and write | ||||
| Basic panel home view 1 | Read and write | ||||
| Basic panel home view 2 | Read and write | ||||
| Basic panel home view 3 | Read and write | ||||
| FBA A enable | Read and write | ||||
| FBA A comm loss func | Read and write | ||||
| FBA A comm loss t out | s | Read and write | |||
| FBA A ref1 type | Read and write | ||||
| FBA A ref2 type | Read and write | ||||
| FBA A SW sel | Read and write | ||||
| FBA A actual 1 type | Read and write | ||||
| FBA A actual 2 type | Read and write | ||||
| FBA A SW transparent source | Read and write | ||||
| FBA A act1 transparent source | Read and write | ||||
| FBA A act2 transparent source | Read and write | ||||
| FBA A debug mode | Read and write | ||||
| FBA A control word | Read | ||||
| FBA A reference 1 | Read | ||||
| FBA A reference 2 | Read | ||||
| FBA A status word | Read | ||||
| FBA A actual value 1 | Read | ||||
| FBA A actual value 2 | Read | ||||
| FBA A type | Read | ||||
| FBA A Par2 | Read and write | ||||
| FBA A Par3 | Read and write | ||||
| FBA A Par4 | Read and write | ||||
| FBA A Par5 | Read and write | ||||
| FBA A Par6 | Read and write | ||||
| FBA A Par7 | Read and write | ||||
| FBA A Par8 | Read and write | ||||
| FBA A Par9 | Read and write | ||||
| FBA A Par10 | Read and write | ||||
| FBA A Par11 | Read and write | ||||
| FBA A Par12 | Read and write | ||||
| FBA A Par13 | Read and write | ||||
| FBA A Par14 | Read and write | ||||
| FBA A Par15 | Read and write | ||||
| FBA A Par16 | Read and write | ||||
| FBA A Par17 | Read and write | ||||
| FBA A Par18 | Read and write | ||||
| FBA A Par19 | Read and write | ||||
| FBA A Par20 | Read and write | ||||
| FBA A Par21 | Read and write | ||||
| FBA A Par22 | Read and write | ||||
| FBA A Par23 | Read and write | ||||
| FBA A Par24 | Read and write | ||||
| FBA A Par25 | Read and write | ||||
| FBA A Par26 | Read and write | ||||
| FBA A par refresh | Read and write | ||||
| FBA A par table ver | Read | ||||
| FBA A drive type code | Read | ||||
| FBA A mapping file ver | Read | ||||
| D2FBA A comm status | Read and write | ||||
| FBA A comm SW ver | Read and write | ||||
| FBA A appl SW ver | Read and write | ||||
| FBA A data in1 | Read and write | ||||
| FBA A data in2 | Read and write | ||||
| FBA A data in3 | Read and write | ||||
| FBA A data in4 | Read and write | ||||
| FBA A data in5 | Read and write | ||||
| FBA A data in6 | Read and write | ||||
| FBA A data in7 | Read and write | ||||
| FBA A data in8 | Read and write | ||||
| FBA A data in9 | Read and write | ||||
| FBA A data in10 | Read and write | ||||
| FBA A data in11 | Read and write | ||||
| FBA A data in12 | Read and write | ||||
| FBA A data out1 | Read and write | ||||
| FBA A data out2 | Read and write | ||||
| FBA A data out3 | Read and write | ||||
| FBA A data out4 | Read and write | ||||
| FBA A data out5 | Read and write | ||||
| FBA A data out6 | Read and write | ||||
| FBA A data out7 | Read and write | ||||
| FBA A data out8 | Read and write | ||||
| FBA A data out9 | Read and write | ||||
| FBA A data out10 | Read and write | ||||
| FBA A data out11 | Read and write | ||||
| FBA A data out12 | Read and write | ||||
| Protocol enable | Read and write | ||||
| Protocol ID | Read | ||||
| Node address | Read and write | ||||
| Baud rate (58.04) | Read and write | ||||
| Parity | Read and write | ||||
| Communication control | Read and write | ||||
| Communication diagnostics | Read | ||||
| Received packets | Read and write | ||||
| Transmitted packets | Read and write | ||||
| All packets | Read and write | ||||
| UART errors | Read and write | ||||
| CRC errors | Read and write | ||||
| Communication loss action (58.14) | Read and write | ||||
| Communication loss mode | Read and write | ||||
| Communication loss time (58.16) | s | Read and write | |||
| Transmit delay | ms | Read and write | |||
| EFB control word | Read | ||||
| EFB status word | Read | ||||
| Control profile | Read and write | ||||
| EFB ref1 type | Read and write | ||||
| EFB ref2 type | Read and write | ||||
| EFB act1 type | Read and write | ||||
| EFB act2 type | Read and write | ||||
| EFB act1 transparent source | Read and write | ||||
| EFB act2 transparent source | Read and write | ||||
| Addressing mode | Read and write | ||||
| Word order | Read and write | ||||
| External PID act value | % | Read and write | |||
| Feedback act value | Read and write | ||||
| Setpoint act value | Read and write | ||||
| Deviation act value | Read and write | ||||
| PID status word | Read | ||||
| PID operation mode | Read and write | ||||
| Feedback 1 source | Read and write | ||||
| Feedback filter time | s | Read and write | |||
| Setpoint scaling | Read and write | ||||
| Output scaling | Read and write | ||||
| Setpoint 1 source | Read and write | ||||
| Internal setpoint sel1 | Read and write | ||||
| Internal setpoint sel2 | Read and write | ||||
| Internal setpoint 1 | Read and write | ||||
| Internal setpoint 2 | Read and write | ||||
| Internal setpoint 3 | Read and write | ||||
| Setpoint min | Read and write | ||||
| Setpoint max | Read and write | ||||
| Deviation inversion | Read and write | ||||
| Gain | Read and write | ||||
| Integration time | s | Read and write | |||
| Derivation time | s | Read and write | |||
| Derivation filter time (71.35) | s | Read and write | |||
| Output min | Read and write | ||||
| Output max | Read and write | ||||
| Output freeze enable | Read and write | ||||
| Deadband range | Read and write | ||||
| Deadband delay | s | Read and write | |||
| Increase prevention | Read and write | ||||
| Decrease prevention | Read and write | ||||
| Internal setpoint actual | Read and write | ||||
| External PID units | Read and write | ||||
| PFC status | Read and write | ||||
| Multipump system status | Read and write | ||||
| Pump status 1 | Read and write | ||||
| Pump status 2 | Read and write | ||||
| Pump status 3 | Read and write | ||||
| Pump status 4 | Read and write | ||||
| Pump status 5 | Read and write | ||||
| Pump status 6 | Read and write | ||||
| Multipump configuration | Read and write | ||||
| Number of motors | Read and write | ||||
| Min number of motors allowed | Read and write | ||||
| Max number of motors allowed | Read and write | ||||
| Start point 1 | Read and write | ||||
| Start point 2 | Read and write | ||||
| Start point 3 | Read and write | ||||
| Start point 4 | Read and write | ||||
| Start point 5 | Read and write | ||||
| Stop point 1 | Read and write | ||||
| Stop point 2 | Read and write | ||||
| Stop point 3 | Read and write | ||||
| Stop point 4 | Read and write | ||||
| Stop point 5 | Read and write | ||||
| Start delay (76.55) | s | Read and write | |||
| Stop delay | s | Read and write | |||
| PFC speed hold on | s | Read and write | |||
| PFC speed hold off | s | Read and write | |||
| PFC contactor delay | s | Read and write | |||
| PFC ramp acceleration time | s | Read and write | |||
| PFC ramp deceleration time | s | Read and write | |||
| PFC autochange | Read and write | ||||
| PFC autochange interval | h | Read and write | |||
| Maximum wear imbalance | h | Read and write | |||
| Autochange level | % | Read and write | |||
| Autochange auxiliary PFC | Read and write | ||||
| PFC 1 interlock | Read and write | ||||
| PFC 2 interlock | Read and write | ||||
| PFC 3 interlock | Read and write | ||||
| PFC 4 interlock | Read and write | ||||
| PFC 5 interlock | Read and write | ||||
| PFC 6 interlock | Read and write | ||||
| Regulator bypass control | Read and write | ||||
| PFC runtime change | Read and write | ||||
| Pump 1 running time | h | Read and write | |||
| Pump 2 running time | h | Read and write | |||
| Pump 3 running time | h | Read and write | |||
| Pump 4 running time | h | Read and write | |||
| Pump 5 running time | h | Read and write | |||
| Pump 6 running time | h | Read and write | |||
| Supply voltage | Read and write | ||||
| Adaptive voltage limits | Read and write | ||||
| Estimated AC supply voltage | V | Read and write | |||
| Control board supply | Read and write | ||||
| Special HW settings | Read and write | ||||
| HW options word 1 | Read and write | ||||
| HW options word 2 | Read and write | ||||
| Language | Read and write | ||||
| Pass code | Read and write | ||||
| Access level status | Read and write | ||||
| Macro select | Read and write | ||||
| Macro active | Read and write | ||||
| Parameter restore | Read and write | ||||
| Parameter save manually | Read and write | ||||
| Control board boot | Read and write | ||||
| User set status | Read | ||||
| User set save/load | Read and write | ||||
| User set I/O mode in1 | Read and write | ||||
| User set I/O mode in2 | Read and write | ||||
| Unit selection | Read and write | ||||
| Time sync primary source | Read and write | ||||
| Clear fault and event logger | Read and write | ||||
| Checksum action | Read and write | ||||
| Checksum control word | Read and write | ||||
| Actual checksumA | Read and write | ||||
| Actual checksumB | Read and write | ||||
| Disable adaptive program | Read and write | ||||
| Approved checksum A | Read and write | ||||
| Approved checksum B | Read and write | ||||
| 550 compatibility mode | Read and write | ||||
| Switching frequency reference | Read and write | ||||
| Minimum switching frequency | Read and write | ||||
| Slip gain | % | Read and write | |||
| Voltage reserve | % | Read and write | |||
| Flux braking | Read and write | ||||
| Optimizer minimum torque | % | Read and write | |||
| TR tuning | % | Read and write | |||
| IR compensation | % | Read and write | |||
| Motor model temperature adaptation | Read and write | ||||
| Stator temperature factor | % | Read and write | |||
| Rotor temperature factor | % | Read and write | |||
| U/F ratio | Read and write | ||||
| Slip gain for scalar | % | Read and write | |||
| IR comp max frequency | % | Read and write | |||
| User motor model mode | Read and write | ||||
| Rs user | Read and write | ||||
| Rr user | Read and write | ||||
| Lm user | Read and write | ||||
| SigmaL user | Read and write | ||||
| Ld user | Read and write | ||||
| Lq user | Read and write | ||||
| PM flux user | Read and write | ||||
| Rs user SI | Ω | Read and write | |||
| Rr user SI | Ω | Read and write | |||
| Lm user SI | Read and write | ||||
| SigmaL user SI | Read and write | ||||
| Ld user SI | Read and write | ||||
| Lq user SI | Read and write | ||||
| Motor type | Read and write | ||||
| Motor control mode | Read and write | ||||
| Motor nominal current | A | Read and write | |||
| Motor nominal voltage | V | Read and write | |||
| Motor nominal frequency | Hz | Read and write | |||
| Motor nominal speed | rpm | Read and write | |||
| Motor nominal power | kW | Read and write | |||
| Motor nominal cos Φ | Read and write | ||||
| Motor nominal torque | Nm | Read and write | |||
| ID run requested | Read and write | ||||
| Last ID run performed | Read and write | ||||
| Motor polepairs calculated | Read and write | ||||
| Motor phase order | Read and write | ||||
| Coil CW Bit 0 OFF1 Control | Read and write | ||||
| Coil CW Bit 1 OFF2 Control | Read and write | ||||
| Coil CW Bit 2 OFF3 Control | Read and write | ||||
| Coil CW Bit 3 Inhibit Operation | Read and write | ||||
| Coil CW Bit 4 Ramp Out Zero | Read and write | ||||
| Coil CW Bit 5 Ramp Hold | Read and write | ||||
| Coil CW Bit 6 Ramp In Zero | Read and write | ||||
| Coil CW Bit 7 Reset | Read and write | ||||
| Coil CW Bit 8 Jogging 1 | Read and write | ||||
| Coil CW Bit 9 Jogging 2 | Read and write | ||||
| Coil CW Bit 10 Remote Cmd | Read and write | ||||
| Coil CW Bit 11 Ext Ctrl Loc | Read and write | ||||
| Coil CW Bit 12 User 0 | Read and write | ||||
| Coil CW Bit 13 User 1 | Read and write | ||||
| Coil CW Bit 14 User 2 | Read and write | ||||
| Coil CW Bit 15 User 3 | Read and write | ||||
| Coil DCU CW Bit 16 FB Local Ctl | Read and write | ||||
| Coil DCU CW Bit 17 FB Local Ref | Read and write | ||||
| Coil DCU CW Bit 22 User 0 | Read and write | ||||
| Coil DCU CW Bit 23 User 1 | Read and write | ||||
| Coil DCU CW Bit 24 User 2 | Read and write | ||||
| Coil DCU CW Bit 25 User 3 | Read and write | ||||
| Coil Relay Output RO1 | Read and write | ||||
| Coil Relay Output RO2 | Read and write | ||||
| Coil Relay Output RO3 | Read and write | ||||
| Coil Relay Output RO4 | Read and write | ||||
| Coil Relay Output RO5 | Read and write | ||||
| Status SW Bit 0 Rdy On | Read | ||||
| Status SW Bit 1 Rdy Run | Read | ||||
| Status SW Bit 2 Rdy Ref | Read | ||||
| Status SW Bit 3 Tripped | Read | ||||
| Status SW Bit 4 Off 2 Status | Read | ||||
| Status SW Bit 5 Off 3 Status | Read | ||||
| Status SW Bit 6 Swc On Inhib | Read | ||||
| Status SW Bit 7 Alarm | Read | ||||
| Status SW Bit 8 At Setpoint | Read | ||||
| Status SW Bit 9 Remote | Read | ||||
| Status SW Bit 10 Above Limit | Read | ||||
| Status SW Bit 11 User 0 | Read | ||||
| Status SW Bit 12 User 1 | Read | ||||
| Status SW Bit 13 User 2 | Read | ||||
| Status SW Bit 14 User 3 | Read | ||||
| Status SW Bit 15 Fault | Read | ||||
| Status DCU SW Bit 16 Alarm | Read | ||||
| Status DCU SW Bit 22 User 0 | Read | ||||
| Status DCU SW Bit 23 User 1 | Read | ||||
| Status DCU SW Bit 24 User 2 | Read | ||||
| Status DCU SW Bit 25 User 3 | Read | ||||
| Status DCU SW Bit 26 Req Ctl | Read | ||||
| Digital Input DI1 Delayed | Read | ||||
| Digital Input DI2 Delayed | Read | ||||
| Digital Input DI3 Delayed | Read | ||||
| Digital Input DI4 Delayed | Read | ||||
| Digital Input DI5 Delayed | Read | ||||
| Digital Input DI6 Delayed | Read |
Loading registers…
Send your device list
If a device is not in the library yet, we build the template for free as soon as we have the register data.
Use cases
- Show motor speed, current and output power of every drive on one dashboard.
- Send an alert by email when the tripping fault code is not 0, so a stopped fan or pump is seen right away.
- Log the energy counters and output power in the history to compare consumption per fan or pump.
- Start, stop or change the speed reference from the portal during commissioning or a service call.
- Switch a relay output of the drive from the portal, for example to control a damper or a warning light.
- Adjust ramp times, speed limits or a PID setpoint remotely without going to the plant room.
Installation
Connect the EIA-485 terminal of the drive (B+, A-, DGND) to the RS485 port of the ModbusCloud Gateway and switch on termination at the last drive on the bus.
Set 58.01 Protocol enable to Modbus RTU.
Set 58.03 Node address, 58.04 Baud rate and 58.05 Parity, for example address 1, 19.2 kbit/s, 8 EVEN 1, and confirm with 58.06 Refresh settings.
In ModbusCloud, add a Modbus RTU device on the Gateway with the same address and import this template.
Check that motor speed and DC voltage come in with plausible values.
Things to watch for
The drive does not answer on the RS485 bus. What should I check?
Check that 58.01 is set to Modbus RTU and that the settings were taken over with 58.06 or a power cycle. The node address in 58.03 is 0 from the factory, so set it to 1 to 247. Address, baud rate and parity must match the Gateway. Swap A and B if nothing comes back, and switch on termination only at both ends of the bus.
Why are the values ten or a hundred times too big, or the words in the wrong order?
The template uses the 32-bit registers with the low word first, which is the default of 58.34 Word order. If 58.34 was changed to HI-LO or 58.33 Addressing mode is not Mode 0, the values come in wrong. Set both back to the default and refresh with 58.06.
How do I start the drive and set the speed safely?
Set 20.01 Ext1 commands and 22.11 Ext1 speed ref1 or 28.11 Ext1 frequency ref1 to the embedded fieldbus first, otherwise the drive ignores the control word and reference. Write settings only within the range the drive allows and read the value back. With the ABB Drives profile the reference is scaled so that 20000 equals 46.01 or 46.02.
A relay output does not follow the coil I write.
The relay coils write bits of 10.99 RO/DIO control word. The relay only follows when its source, for example 10.24 RO1 source, is set to that bit. Coils and discrete inputs use the reference from the manual minus 1; check the first read against the status on the drive panel.
Want to see how it works?