AC Heating AC Heating heatpump with xCC regulation system Modbus TCP template

AC Heating heatpump with xCC regulation system

Controls and monitors AC Heating heat pumps with xCC regulation via Modbus TCP

Template for AC Heating heat pumps with xCC regulation system via Modbus TCP. Reads temperatures, power values, error codes, and circuit status. Allows control of heating setpoints, DHW parameters, and the main switch.

Protocol
Modbus TCP
Connection
Ethernet, Modbus TCP
Registers
35, read and write
Key readings
Actual and requested temperatures · Outside temperature · DHW temperature · HP power and system power · Error codes (critical and non-critical) · Heating and DHW circuit status
Available commands
Main switch and circuit enables · Heating room request and water setpoints · DHW min, max, and sanitation temperature · DHW circulation control
Compatible models
AC Heating Convert AW · AC Heating Compact AW · xCC
Last updated

Registers (35)

19 read, 16 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
T_Act°CRead
T_Req°CRead
Sys_act_powerWRead
Outside_t°CRead
T_Ret°CRead
Heat1_act_room_t°CRead
DHW_t°CRead
HP_PowerWRead
ErrRead
Err_non_critRead
Err_criticalRead
LRTRead
Heater_actRead
DHW_actRead
Heat1_actRead
DHW_last_sanithRead
DHW_circ_actRead
Heat2_actRead
Heat2_act_room_t°CRead
Heat1_room_req°CWrite
Heat1_water_const°CWrite
DHW_Max°CWrite
DHW_Min°CWrite
Ext_T_1°CWrite
Ext_T_2°CWrite
Main_SwitchWrite
Heat1_EnWrite
DHW_EnWrite
DWH_Sanit_t°CWrite
DHW_circ_enWrite
DHW_circ_manualWrite
DHW_circ_man_stateWrite
Heat2_EnWrite
Heat2_room_req°CWrite
Heat2_water_const°CWrite

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Monitor real-time heating and DHW temperatures on a cloud dashboard for remote customer support.
  • Create an alert when a critical error code appears on the AC Heating heat pump.
  • Adjust DHW min and max temperature setpoints remotely to optimise energy consumption.
  • Track heat pump power and system power over time to analyse seasonal efficiency.
  • Enable or disable heating circuits from the dashboard based on occupancy schedules.
  • Receive a notification when the outside temperature drops below a threshold so you can verify setpoints.

Installation

  1. Verify that the xCC controller runs firmware 5.5.2 or higher for old indoor unit designs, or 8.2.2 or higher for new indoor unit designs.

  2. Connect the ModbusCloud Gateway to the same local IP network as the xCC controller.

  3. Note the IP address and Modbus unit ID configured on the xCC controller for use during template setup.

  4. Import the AC Heating xCC template in the ModbusCloud portal and assign the correct IP address and unit ID.

  5. Confirm that status registers are returning valid temperature and power readings on the live data view.

  6. Configure dashboards, alerts, and control widgets in ModbusCloud to match the installation requirements.

Things to watch for

Which firmware version does the xCC controller need?

For the older indoor unit design, firmware 5.5.2 or higher is required. For the newer indoor unit design, firmware 8.2.2 or higher is required. Check the xCC display or web interface to confirm the running version.

Do I need RS-485 wiring between the gateway and the heat pump?

No. The AC Heating xCC system communicates over Modbus TCP, so a standard Ethernet network connection between the gateway and the xCC controller is sufficient.

Registers return zero or no data after importing the template. What should I check?

Verify that the IP address and Modbus unit ID in the template match the xCC controller settings. Also confirm the xCC firmware meets the minimum version requirement for your indoor unit type.

Can I control DHW circulation and sanitation temperature remotely?

Yes. The template includes write registers for DHW circulation control, sanitation temperature, and DHW min/max setpoints. Ensure the corresponding functions are enabled on the xCC controller.