AC Heating heatpump with xCC regulation system
Controls and monitors AC Heating heat pumps with xCC regulation via Modbus TCP
Template for AC Heating heat pumps with xCC regulation system via Modbus TCP. Reads temperatures, power values, error codes, and circuit status. Allows control of heating setpoints, DHW parameters, and the main switch.
- Protocol
- Modbus TCP
- Connection
- Ethernet, Modbus TCP
- Registers
- 35, read and write
- Brand
- AC Heating
- Key readings
- Actual and requested temperatures · Outside temperature · DHW temperature · HP power and system power · Error codes (critical and non-critical) · Heating and DHW circuit status
- Available commands
- Main switch and circuit enables · Heating room request and water setpoints · DHW min, max, and sanitation temperature · DHW circulation control
- Compatible models
- AC Heating Convert AW · AC Heating Compact AW · xCC
- Last updated
Registers (35)
19 read, 16 write
| Name | Unit | Access | Address (Hidden until you enter your email) | Function (hidden) | Type (hidden) |
|---|---|---|---|---|---|
| T_Act | °C | Read | |||
| T_Req | °C | Read | |||
| Sys_act_power | W | Read | |||
| Outside_t | °C | Read | |||
| T_Ret | °C | Read | |||
| Heat1_act_room_t | °C | Read | |||
| DHW_t | °C | Read | |||
| HP_Power | W | Read | |||
| Err | Read | ||||
| Err_non_crit | Read | ||||
| Err_critical | Read | ||||
| LRT | Read | ||||
| Heater_act | Read | ||||
| DHW_act | Read | ||||
| Heat1_act | Read | ||||
| DHW_last_sanit | h | Read | |||
| DHW_circ_act | Read | ||||
| Heat2_act | Read | ||||
| Heat2_act_room_t | °C | Read | |||
| Heat1_room_req | °C | Write | |||
| Heat1_water_const | °C | Write | |||
| DHW_Max | °C | Write | |||
| DHW_Min | °C | Write | |||
| Ext_T_1 | °C | Write | |||
| Ext_T_2 | °C | Write | |||
| Main_Switch | Write | ||||
| Heat1_En | Write | ||||
| DHW_En | Write | ||||
| DWH_Sanit_t | °C | Write | |||
| DHW_circ_en | Write | ||||
| DHW_circ_manual | Write | ||||
| DHW_circ_man_state | Write | ||||
| Heat2_En | Write | ||||
| Heat2_room_req | °C | Write | |||
| Heat2_water_const | °C | Write |
Loading registers…
Send your device list
If a device is not in the library yet, we build the template for free as soon as we have the register data.
Use cases
- Monitor real-time heating and DHW temperatures on a cloud dashboard for remote customer support.
- Create an alert when a critical error code appears on the AC Heating heat pump.
- Adjust DHW min and max temperature setpoints remotely to optimise energy consumption.
- Track heat pump power and system power over time to analyse seasonal efficiency.
- Enable or disable heating circuits from the dashboard based on occupancy schedules.
- Receive a notification when the outside temperature drops below a threshold so you can verify setpoints.
Installation
Verify that the xCC controller runs firmware 5.5.2 or higher for old indoor unit designs, or 8.2.2 or higher for new indoor unit designs.
Connect the ModbusCloud Gateway to the same local IP network as the xCC controller.
Note the IP address and Modbus unit ID configured on the xCC controller for use during template setup.
Import the AC Heating xCC template in the ModbusCloud portal and assign the correct IP address and unit ID.
Confirm that status registers are returning valid temperature and power readings on the live data view.
Configure dashboards, alerts, and control widgets in ModbusCloud to match the installation requirements.
Things to watch for
Which firmware version does the xCC controller need?
For the older indoor unit design, firmware 5.5.2 or higher is required. For the newer indoor unit design, firmware 8.2.2 or higher is required. Check the xCC display or web interface to confirm the running version.
Do I need RS-485 wiring between the gateway and the heat pump?
No. The AC Heating xCC system communicates over Modbus TCP, so a standard Ethernet network connection between the gateway and the xCC controller is sufficient.
Registers return zero or no data after importing the template. What should I check?
Verify that the IP address and Modbus unit ID in the template match the xCC controller settings. Also confirm the xCC firmware meets the minimum version requirement for your indoor unit type.
Can I control DHW circulation and sanitation temperature remotely?
Yes. The template includes write registers for DHW circulation control, sanitation temperature, and DHW min/max setpoints. Ensure the corresponding functions are enabled on the xCC controller.
Want to see how it works?