4033_T1 (Temperatur 1) | 4033 | FC04 | int16 | °C | R |
4001_pH | 4001 | FC04 | uint16 | pH | R |
4008_Cl (free chlorine) / Br (free bromine) | 4008 | FC04 | uint16 | mg/l | R |
4022_Redox | 4022 | FC04 | uint16 | mV | R |
3002_Lower Alarm threshold pH | 3002 | FC04 | uint16 | pH | R |
3003_Upper Alarm threshold pH | 3003 | FC04 | uint16 | pH | R |
3001_Setpoint pH | 3001 | FC04 | uint16 | pH | R |
3017_Setpoint Chlorine / Bromine | 3017 | FC04 | uint16 | mg/l | R |
3018_Lower Alarm threshold Chlorine / Bromine | 3018 | FC04 | uint16 | mg/l | R |
3019_Upper Alarm threshold Chlorine / Bromine | 3019 | FC04 | uint16 | mg/l | R |
3049_Setpoint Redox (mV) | 3049 | FC04 | uint16 | mV | R |
3050_Setpoint Redox (mV) | 3050 | FC04 | uint16 | mV | R |
3051_Lower Alarm threshold Redox (mV) | 3051 | FC04 | uint16 | mV | R |
3052_Lower Alarm threshold Redox (mV) | 3052 | FC04 | uint16 | mV | R |
3053_Upper Alarm threshold Redox (mV) | 3053 | FC04 | uint16 | mV | R |
3054_Upper Alarm threshold Redox (mV) | 3054 | FC04 | uint16 | mV | R |
3069_Lower Alarm threshold T1 | 3069 | FC04 | uint16 | °C | R |
3070_Upper Alarm threshold T1 | 3070 | FC04 | uint16 | °C | R |
3074_Lower Alarm threshold T2 | 3074 | FC04 | uint16 | °C | R |
3075_Upper Alarm threshold T2 | 3075 | FC04 | uint16 | °C | R |
3079_Lower Alarm threshold T3 | 3079 | FC04 | uint16 | °C | R |
3080_Upper Alarm threshold T3 | 3080 | FC04 | uint16 | °C | R |
3084_Basic dosing amount O2 | 3084 | FC04 | uint16 | l | R |
4047_Battery | 4047 | FC04 | uint16 | V | R |
4069_T2 (Temperatur 2) | 4069 | FC04 | uint16 | °C | R |
4071_T3 (Temperatur 3) | 4071 | FC04 | uint16 | °C | R |
4106_Total chlorine | 4106 | FC04 | uint16 | mg/l | R |
4077_O2 (dosed amount O2) | 4077 | FC04 | uint16 | l | R |
4108_Combined chlorine | 4108 | FC04 | uint16 | mg/l | R |
4109_Active chlorine | 4109 | FC04 | uint16 | mg/l | R |
2001_Collective alarm | 2001 | FC02 | uint16 | | R |
2002_Power-on Delay | 2002 | FC02 | uint16 | | R |
2003_No flow signal (input flow) | 2003 | FC02 | uint16 | | R |
2004_No flow signal (input IN1) | 2004 | FC02 | uint16 | | R |
2005_Upper Alarm pH | 2005 | FC02 | uint16 | | R |
2006_Lower Alarm pH | 2006 | FC02 | uint16 | | R |
2009_Dosing Alarm pH | 2009 | FC02 | uint16 | | R |
2010_Upper Alarm Chlorine / Bromine | 2010 | FC02 | uint16 | | R |
2011_Lower Alarm Chlorine / Bromine | 2011 | FC02 | uint16 | | R |
2012_Level Alarm Chlorine | 2012 | FC02 | uint16 | | R |
2013_Level Warning Chlorine | 2013 | FC02 | uint16 | | R |
2014_Dosing Alarm Chlorine / Bromine | 2014 | FC02 | uint16 | | R |
2019_Upper Alarm Redox | 2019 | FC02 | uint16 | | R |
2020_Lower Alarm Redox | 2020 | FC02 | uint16 | | R |
2021_Level Alarm Redox | 2021 | FC02 | uint16 | | R |
2022_Level Warning Redox | 2022 | FC02 | uint16 | | R |
2023_Dosing Alarm Redox | 2023 | FC02 | uint16 | | R |
2024_Level Alarm O2 (Bayrosoft (R)) | 2024 | FC02 | uint16 | | R |
2025_Level Warning O2 (Bayrosoft (R)) | 2025 | FC02 | uint16 | | R |
2028_Upper Alarm Temperature T1 | 2028 | FC02 | uint16 | | R |
2029_Lower Alarm Temperature T1 | 2029 | FC02 | uint16 | | R |
2030_Upper Alarm Temperature T2 | 2030 | FC02 | uint16 | | R |
2031_Lower Alarm Temperature T2 | 2031 | FC02 | uint16 | | R |
2032_Upper Alarm Temperature T3 | 2032 | FC02 | uint16 | | R |
2033_Lower Alarm Temperature T3 | 2033 | FC02 | uint16 | | R |
2034_Battery Alarm | 2034 | FC02 | uint16 | | R |
2035_Level Alarm pH+ | 2035 | FC02 | uint16 | | R |
2036_Level Warning pH+ | 2036 | FC02 | uint16 | | R |
2037_Level Alarm pH- | 2037 | FC02 | uint16 | | R |
2038_Level Warning pH- | 2038 | FC02 | uint16 | | R |
2039_Level Alarm Flockmatic (R) | 2039 | FC02 | uint16 | | R |