Ingeteam Modbus templates
All 4 available Ingeteam templates for ModbusCloud.
Monitor Ingeteam Ingecon solar inverters, 1Play, 3Play, Lite and HF, via Modbus RTU with power limiting and start/stop.
- Templates
- 4
- Connection
- Modbus RTU
- Registers
- 14 to 45 per template
- Compatible models
- Ingecon 3Play · Ingecon 1 Play TL M · Ingecon 1Play HF · Ingecon Lite
- Last updated
Ingeteam templates
4 via Modbus RTU
Ingeteam Ingecon 3PlayMonitors and controls Ingeteam 3-phase PV inverters via Modbus.Modbus RTU43 read, 2 write
Ingeteam Ingecon 1Play TL MMonitors and controls Ingeteam Ingecon 1Play TL M solar inverter via ModbusModbus RTU28 read, 2 write
Ingeteam Ingecon 1Play HFControls and monitors Ingecon 1Play HF solar inverter via ModbusModbus RTU24 read, 2 write
Ingeteam Ingecon LiteControls an Ingeteam 1-phase inverter via Modbus RTU.Modbus RTU12 read, 2 write
The scan recognises these devices
Connect them to RS485 or the network and start a scan in the portal.
Gateway
Portal
Incl. 4G data up to 30 MB per month
Excl. VAT. White label customer portal included. All prices
Order your first gateway100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

Ingeteam is a Spanish manufacturer of power-conversion equipment, with the Ingecon inverter range deployed in residential and commercial PV. The 4 Ingeteam Modbus RTU templates in our library cover the Ingecon 1Play HF, Ingecon 1Play TL M, Ingecon 3Play, and Ingecon Lite, spanning single-phase and three-phase inverters with and without high-frequency isolation.
With ModbusCloud and these Ingeteam Modbus RTU templates you read AC and DC voltages, currents, active power, energy totals, PV string currents, frequency, cos phi, alarm codes, operation hours, and self-consumption data. Writable registers allow active power limitation (for DSO curtailment or grid-code compliance) and start/stop control for maintenance or safety windows. The 3Play variant adds per-string current monitoring for fault diagnosis.
All 4 Ingeteam templates are free to browse. Import one into your ModbusCloud portal to supervise Ingeteam PV inverters with remote start/stop and dynamic power-limit control.
What you can read out
- AC and DC voltage, current and power
- Energy totals and self-consumption data
- PV string currents (3Play)
- Alarm codes and operation hours
- Remote power limit and start/stop
Typical installations
- Residential PV with grid-code power-limit enforcement
- Commercial three-phase PV with per-string diagnostics
- Installer fleet with remote inverter control