EnerCharge DC-Supercharger
EnerCharge
Monitors and controls an EnerCharge DC supercharger e-charging station via Modbus TCP.
Overview
Key readings
- Actual Total Power
- Charging State
- Plug State
- SOC
- Resttime 80/100
- AC/DC Voltage and Current L1

EnerCharge
Monitors and controls an EnerCharge DC supercharger e-charging station via Modbus TCP.
16 read / 2 write
| Name | Address | Function | Type | Unit | Access |
|---|---|---|---|---|---|
Maximum system performance | 100 | FC03 | uint16 | R | |
Actual_Total_Power | 102 | FC03 | uint16 | W | R |
Minimum system performance | 101 | FC03 | uint16 | R | |
Readback value for power limitation | 103 | FC03 | uint16 | W | R |
ChargingState | 417 | FC03 | uint16 | R | |
Max_Power_Car | 418 | FC03 | uint16 | W | R |
Plug_State | 416 | FC03 | uint16 | R | |
Present_Energy | 410 | FC03 | uint16 | Wh | R |
SOC | 411 | FC03 | uint16 | % | R |
Resttime_80 | 412 | FC03 | uint16 | min | R |
Resttime_100 | 413 | FC03 | uint16 | min | R |
Power | 400 | FC03 | uint16 | W | R |
AC/DC Voltage_L1 | 402 | FC03 | uint16 | V | R |
AC/DC Current_L1 | 405 | FC03 | uint16 | A | R |
Setvalue_Powerlimit | 200 | FC03 | uint16 | W | R/W |
Setvalue_Emergency_Powerlimit | 201 | FC03 | uint16 | W | R/W |
ModbusCloud is the hardware-plus-software platform that installers use to monitor, visualise and control Modbus devices from one portal. This template is one of hundreds you can use right away.
Summer sale: 10% off with code SUMMER10
The pre-commissioning checklist for every RS485 bus. Print it and take it to site.
We send you the checklist plus an occasional practical Modbus tip. No spam, unsubscribe anytime.

Algodue Elettronica S.r.l.
Measures single-phase energy consumption and production via Modbus TCP.

Sigenergy

Fronius
Monitors and controls Fronius GEN24 inverters and PV batteries via SunSpec Modbus TCP

Huawei
Monitors HUAWEI SUN2000 inverter, LUNA2000 battery, and Smart Power Sensor via Modbus TCP.

NIBE

Fronius
Monitors Fronius Symo and Primo inverters via Modbus TCP