EnerCharge DC-Supercharger
Monitors and controls an EnerCharge DC supercharger e-charging station via Modbus TCP.
This template integrates the EnerCharge DC-Supercharger e-charging station via Modbus TCP. It reads charging status, power, SOC, voltage, current, and remaining charge times. It also allows setting power limits and emergency power limits.
- Protocol
- Modbus TCP
- Connection
- Ethernet, Modbus TCP
- Registers
- 16, read and write
- Brand
- EnerCharge
- Key readings
- Actual Total Power · Charging State · Plug State · SOC · Resttime 80/100 · AC/DC Voltage and Current L1
- Available commands
- Setvalue Powerlimit · Setvalue Emergency Powerlimit
- Compatible models
- EnerCharge DC-Supercharger
- Last updated
Registers (16)
16 read, 2 write
| Name | Unit | Access | Address (Hidden until you enter your email) | Function (hidden) | Type (hidden) |
|---|---|---|---|---|---|
| Maximum system performance | Read | ||||
| Actual_Total_Power | W | Read | |||
| Minimum system performance | Read | ||||
| Readback value for power limitation | W | Read | |||
| ChargingState | Read | ||||
| Max_Power_Car | W | Read | |||
| Plug_State | Read | ||||
| Present_Energy | Wh | Read | |||
| SOC | % | Read | |||
| Resttime_80 | min | Read | |||
| Resttime_100 | min | Read | |||
| Power | W | Read | |||
| AC/DC Voltage_L1 | V | Read | |||
| AC/DC Current_L1 | A | Read | |||
| Setvalue_Powerlimit | W | Read and write | |||
| Setvalue_Emergency_Powerlimit | W | Read and write |
Loading registers…
Send your device list
If a device is not in the library yet, we build the template for free as soon as we have the register data.
Use cases
- Monitor real-time charging power and state of charge on a live dashboard for site operators.
- Set dynamic power limits to align EV charging with peak shaving or load management strategies.
- Create an alert when plug state changes unexpectedly or charging state indicates a fault.
- Track remaining charge times to 80% and 100% for fleet scheduling and availability planning.
- Configure an emergency power limit as a fallback when the control system loses communication.
- Log AC and DC voltage and current values over time for energy reporting and billing verification.
Installation
Activate the complex control mode and Modbus TCP port on the EnerCharge DC-Supercharger through the station's local configuration interface.
Connect the ModbusCloud Gateway to the same local network as the charging station and ensure IP connectivity.
Note the IP address and Modbus TCP port of the EnerCharge DC-Supercharger and enter these in the ModbusCloud gateway configuration.
Import the EnerCharge DC-Supercharger template from the ModbusCloud template library and assign it to the configured connection.
Verify communication by checking that live values such as Charging State and Actual Total Power appear in the ModbusCloud dashboard.
Things to watch for
The gateway cannot connect to the EnerCharge DC-Supercharger. What should I check?
Verify that the complex control mode and the Modbus TCP port are both enabled on the charging station. Also confirm that the gateway and charger are on the same network and that no firewall is blocking the configured TCP port.
Power limit values do not seem to take effect on the charger.
Ensure that the complex control mode is active. In standard operating mode, the charger may ignore external setpoints. Also verify you are writing the correct data format and unit expected by the charger.
SOC and Resttime registers show zero even though a vehicle is charging.
Some values are only populated once a charging session is actively underway and the vehicle provides SOC data. Not all vehicles transmit SOC information to the charger, which may result in zero values.
What happens if the ModbusCloud gateway loses connection to the charger?
The EnerCharge DC-Supercharger can fall back to the configured Emergency Powerlimit value. Make sure this value is set appropriately so the station continues to operate safely without active control.