FIMER TRIO-5.8/7.5/8.5-TL-OUTD (VSN300)

Three-phase PV inverter with AC, DC per MPPT input, energy, temperature and state values over Modbus TCP.

The FIMER TRIO-5.8, 7.5 and 8.5-TL-OUTD are three-phase string inverters for PV systems on homes and small businesses, read over the network through the VSN300 Wifi Logger Card. This Modbus TCP template reads AC power, lifetime energy, voltage and current per phase, DC power per MPPT input, temperatures and the inverter state in ModbusCloud.

Protocol
Modbus TCP
Connection
Ethernet, Modbus TCP
Registers
82, read only
Brand
FIMER
Key readings
AC power · Lifetime energy · Phase voltages and currents · Grid frequency · DC power per MPPT input · Inverter temperature · Operating state
Compatible models
TRIO-5.8-TL-OUTD · TRIO-5.8-TL-OUTD-S · TRIO-7.5-TL-OUTD · TRIO-7.5-TL-OUTD-S · TRIO-8.5-TL-OUTD · TRIO-8.5-TL-OUTD-S · ABB TRIO-5.8-TL-OUTD · ABB TRIO-7.5-TL-OUTD · ABB TRIO-8.5-TL-OUTD · Power-One TRIO-5.8-TL-OUTD · Power-One TRIO-7.5-TL-OUTD · Power-One TRIO-8.5-TL-OUTD
Last updated

Registers (82)

82 read, 0 write

NameUnitAccessAddress (Hidden until you enter your email)Function (hidden)Type (hidden)
AC PowerWRead
Total EnergyWhRead
AC Voltage Phase AVRead
AC Voltage Phase BVRead
AC Voltage Phase CVRead
AC Voltage ABVRead
AC Voltage BCVRead
AC Voltage CAVRead
AC CurrentARead
AC Current Phase AARead
AC Current Phase BARead
AC Current Phase CARead
AC FrequencyHzRead
AC Apparent PowerVARead
AC Reactive PowervarRead
Power Factor%Read
DC PowerWRead
DC CurrentARead
DC VoltageVRead
MPPT 1 DC CurrentARead
MPPT 1 DC VoltageVRead
MPPT 1 DC PowerWRead
MPPT 1 Lifetime EnergyWhRead
MPPT 2 DC CurrentARead
MPPT 2 DC VoltageVRead
MPPT 2 DC PowerWRead
MPPT 2 Lifetime EnergyWhRead
Cabinet Temperature°CRead
Heat Sink Temperature°CRead
Transformer Temperature°CRead
Other Temperature°CRead
MPPT 1 Temperature°CRead
MPPT 2 Temperature°CRead
Operating StateRead
Vendor Operating StateRead
Event FlagsRead
Vendor Event Flags 1Read
Vendor Event Flags 2Read
Vendor Event Flags 3Read
Vendor Event Flags 4Read
MPPT Global EventsRead
MPPT 1 Operating StateRead
MPPT 1 EventsRead
MPPT 2 Operating StateRead
MPPT 2 EventsRead
AC Current Scale FactorRead
AC Voltage Scale FactorRead
AC Power Scale FactorRead
AC Frequency Scale FactorRead
AC Apparent Power Scale FactorRead
AC Reactive Power Scale FactorRead
Power Factor Scale FactorRead
Total Energy Scale FactorRead
DC Current Scale FactorRead
DC Voltage Scale FactorRead
DC Power Scale FactorRead
Temperature Scale FactorRead
MPPT Current Scale FactorRead
MPPT Voltage Scale FactorRead
MPPT Power Scale FactorRead
MPPT Energy Scale FactorRead
ManufacturerRead
ModelRead
OptionsRead
Firmware VersionRead
Serial NumberRead
Device AddressRead
Number Of MPPT InputsRead
MPPT Timestamp PeriodRead
MPPT 1 Input IDRead
MPPT 1 Input NameRead
MPPT 1 TimestampsRead
MPPT 2 Input IDRead
MPPT 2 Input NameRead
MPPT 2 TimestampsRead
SunSpec IDRead
Common Model IDRead
Common Model LengthRead
Inverter Model IDRead
Inverter Model LengthRead
MPPT Model IDRead
MPPT Model LengthRead

Loading registers…

Send your device list

If a device is not in the library yet, we build the template for free as soon as we have the register data.

Number of installations (optional)

Use cases

  • Show AC power and lifetime energy of the PV system on a ModbusCloud dashboard next to the energy meter of the grid connection.
  • Get an email alert when the operating state of the inverter changes to fault.
  • Compare the DC power of both MPPT inputs in the history to find a shaded or failing string.
  • Follow the heat sink temperature through the summer to see whether the inverter throttles in the afternoon.
  • Export a year of energy readings as CSV for a yield report.

Installation

  1. Fit the VSN300 Wifi Logger Card in the inverter, connect it to the local WiFi network and give it a fixed IP address in the router.

  2. In the VSN300 web interface, open the logger settings and enable Modbus TCP.

  3. Connect the ModbusCloud Gateway to the same network with a network cable.

  4. In ModbusCloud, add a Modbus TCP device with the IP address of the VSN300, port 502 and unit ID 2, then import this template.

  5. Read the scale factors once, set the scale of the matching registers, and check that AC Power and Total Energy show plausible values.

Things to watch for

The Gateway gets no answer from the inverter. What should I check?

Check that Modbus TCP is enabled in the logger settings of the VSN300, that you use port 502, and that the VSN300 and the ModbusCloud Gateway are in the same network. If unit ID 2 does not answer, try 247; which one applies depends on how the card talks to the inverter. Give the VSN300 a fixed IP address so it does not change after a restart.

Why are current, voltage or temperature 10 or 100 times too high?

These values have a separate scale factor register, a power of ten such as -1 or -2. Read the scale factor, then edit the register in ModbusCloud and set its scale to 0.1 for -1 or 0.01 for -2. Check the scale factors again after a firmware update.

Why do some registers read 65535 or -32768?

That is how the inverter marks a value it does not provide. The total DC current and DC voltage can stay empty; use the values per MPPT input instead. On a TRIO with a single MPPT input, input 2 stays empty.

Why does the inverter not answer at night?

The VSN300 is powered by the inverter. When the inverter switches off after sunset, the card is off too and the Gateway gets no answer until the morning. Expect gaps in the history at night and keep this in mind when you set alarms on this inverter.

The AC values work, but the MPPT registers return an error. Why?

On the TRIO the MPPT block starts at address 122, and MPPT Model ID then reads 160. If that register reads something else or returns an error, the block sits elsewhere on this inverter or is missing. Remove the MPPT registers from the device; the AC values and the total DC values keep working.