NRGkick Wallbox
Monitors and controls NRGkick EV wallbox charging via Modbus TCP.
This template connects NRGkick 11kW and 22kW wallboxes to ModbusCloud via Modbus TCP. It reads energy, power, voltage, current, temperature, and charging status. It also provides control over charging current, phase count, and charge pause.
- Protocol
- Modbus TCP
- Connection
- Ethernet, Modbus TCP
- Registers
- 35, read and write
- Brand
- NRGkick
- Key readings
- Active power all phases · Voltage L1 to L3 · Current L1 to L3 · Total charged energy · Charging status · Housing temperature
- Available commands
- Charging current (A) · Maximum charge phases count · Charge pause enable/disable
- Compatible models
- NRGkick 11kW · NRGkick 22kW
- Last updated
Registers (35)
32 read, 3 write
| Name | Unit | Access | Address (Hidden until you enter your email) | Function (hidden) | Type (hidden) |
|---|---|---|---|---|---|
| Housing Temperature (°C) | °C | Read | |||
| Detected grid voltage type (V) | V | Read | |||
| Totaly charged energy (kWh) | kWh | Read | |||
| Active power of all phases (kW) | kW | Read | |||
| Active Power of phase L1 (W) | W | Read | |||
| Active Power of phase L2 (W) | W | Read | |||
| Active Power of phase L3 (W) | W | Read | |||
| Voltage of phase L1 (V) | V | Read | |||
| Voltage of phase L2 (V) | V | Read | |||
| Detected grid frequency type (Hz) | Hz | Read | |||
| Connected phases on grid side | Read | ||||
| Attachment phase1 temperature (°C) | °C | Read | |||
| Attachment phase2 temperature (°C) | °C | Read | |||
| Attachment phase3 temperature (°C) | °C | Read | |||
| Charging status of the NRGkick / EV | Read | ||||
| Vehicle plug-in cycle count | count | Read | |||
| Apparent power of phase L1 (VA) | VA | Read | |||
| Apparent power of phase L2 (VA) | VA | Read | |||
| Apparent power of phase L3 (VA) | VA | Read | |||
| Reactive power of phase L1 (VAR) | VAR | Read | |||
| Reactive power of phase L2 (VAR) | VAR | Read | |||
| Reactive power of phase L3 (VAR) | VAR | Read | |||
| Reactive power of all phases (VAR) | VAR | Read | |||
| Apparent power of all phases (VA) | VA | Read | |||
| Current of phase L1 (A) | A | Read | |||
| Current of phase L2 (A) | A | Read | |||
| Current of phase L3 (A) | A | Read | |||
| Current of neutral conductor (A) | A | Read | |||
| Power factor of all phases | Read | ||||
| Current frequency (Hz) | Hz | Read | |||
| Current switched relais | Read | ||||
| Average of all phase-voltages (V) | V | Read | |||
| Charge pause disabled / enabled | Write | ||||
| User-set charging current in Ampere | A | Write | |||
| User-set maximum charge phases count | count | Write |
Loading registers…
Send your device list
If a device is not in the library yet, we build the template for free as soon as we have the register data.
Use cases
- Monitor live charging power, voltage, and current per phase on a cloud dashboard for each NRGkick wallbox.
- Create an alert when the NRGkick housing temperature exceeds a safe threshold during prolonged charging sessions.
- Control charging current and phase count remotely to implement dynamic load balancing across multiple EV chargers.
- Track total charged energy per wallbox to generate usage reports for billing or energy audits.
- Pause and resume charging sessions remotely via the ModbusCloud platform without physical access to the wallbox.
- Combine NRGkick charging data with solar production readings to visualize self-consumption in real time.
Installation
Ensure the NRGkick wallbox and the ModbusCloud Gateway are connected to the same local network.
Assign a static IP address to the NRGkick wallbox or create a DHCP reservation so the address does not change.
In the ModbusCloud portal, import the NRGkick Wallbox template and enter the wallbox IP address and Modbus TCP port (default 502).
Verify that data appears on the dashboard by checking live values for voltage, current, and charging status.
If you plan to control charging current or phase count, test write commands with a low current value first and confirm the wallbox responds correctly.
Consult the official NRGkick API documentation for register behavior details when calculating phase count and current for a desired power setpoint.
Things to watch for
Why can I not set a desired charging power directly on the NRGkick wallbox?
The NRGkick wallbox does not accept a direct power setpoint via Modbus. You need to calculate the required number of phases and the current in amperes to reach your target power. For example, 7.4kW single phase at 230V requires approximately 32A.
What Modbus TCP port does the NRGkick wallbox use?
The default Modbus TCP port is 502. Verify this in your NRGkick settings or API documentation if the connection fails.
The gateway cannot connect to the wallbox. What should I check?
Confirm that the wallbox and the gateway are on the same subnet. Check that the wallbox IP address is correct and that no firewall rules block port 502. A static IP or DHCP reservation is recommended.
Does this template work with both the 11kW and 22kW NRGkick models?
Yes. The Modbus TCP register map is the same for both variants. The template supports the NRGkick 11kW and the NRGkick 22kW.
Want to see how it works?