Intesis Modbus templates
All 5 available Intesis templates for ModbusCloud.
Monitor and control AC systems from Daikin, LG, Panasonic and more via IntesisBox Modbus RTU gateways.
- Templates
- 5
- Connection
- Modbus RTU
- Registers
- 5 to 15 per template
- Compatible models
- INMBSLGE001R000 · MBS-1 · PA-RC2-MBS-1 · INMBSPAN001R000 · DK-RC-MBS-1
- Last updated
Intesis templates
5 via Modbus RTU
IntesisBox INMBSLGE001R000Controls LG air conditioners via Modbus RTU integrationModbus RTU8 read, 6 write
IntesisBoxControls AC units via Intesis MBS-1 Modbus RTU gateways.Modbus RTU15 read, 12 write
IntesisBox PA-RC2-MBS-1Controls Panasonic air conditioners via Modbus RTU interfaceModbus RTU1 read, 4 write
IntesisBox INMBSPAN001R000Controls Panasonic and Sanyo air conditioners via Modbus RTU interface.Modbus RTU7 read, 6 write
IntesisBox DK-RC-MBS-1Controls Daikin SKY and VRV air conditioners via Modbus RTUModbus RTU12 read, 9 write
The scan recognises these devices
Connect them to RS485 or the network and start a scan in the portal.
Gateway
Portal
Incl. 4G data up to 30 MB per month
Excl. VAT. White label customer portal included. All prices
Order your first gateway100-day money-back guaranteeIf the gateway fails to connect to a Modbus device from our template library, you get your money back.

Intesis (part of HMS Networks) produces purpose-built protocol gateways that expose proprietary AC buses as standard Modbus RTU registers. The 5 Intesis Modbus RTU templates in our library cover the generic IntesisBox, the DK-RC-MBS-1 gateway for Daikin Sky Air and VRV systems, INMBSLGE001R000 for LG air conditioners, INMBSPAN001R000 and PA-RC2-MBS-1 for Panasonic (and Sanyo) AC units.
With ModbusCloud and these Intesis Modbus RTU templates you read and write on/off, operation mode, fan speed, vane position, temperature setpoint, and alarm status across a wide range of AC brands. The gateway handles all protocol translation, so a ModbusCloud integration looks the same whether the AC beneath it is Daikin VRV, LG, or Panasonic. Error codes and unit faults are surfaced as read-only registers for alerting and remote diagnostics.
All 5 Intesis templates are free to browse. Import one into your ModbusCloud portal to unify AC control across mixed-vendor installations without touching manufacturer-specific firmware.
What you can read out
- On/off state and operation mode
- Fan speed and vane position
- Temperature setpoint and ambient temperature
- Alarm status and error codes
- Per-unit connection state
Typical installations
- Mixed-vendor AC fleets in commercial real estate
- Retrofit BMS projects preserving existing AC units
- Hospitality and hotels with per-room AC control
Want to see how it works?